System informations
*******************************
Name: SYMKLOUD
chassis: ms2900
Health: Healthy
*******************************
Fans: 
*******************************
Fan 1: 
	Present :true
	Status :Healthy
	8316 RPM
Fan 2: 
	Present :true
	Status :Healthy
	8316 RPM
Fan 3: 
	Present :true
	Status :Healthy
	8393 RPM
Fan 4: 
	Present :true
	Status :Healthy
	8393 RPM
Fan 5: 
	Present :true
	Status :Healthy
	8393 RPM


*******************************
PSU: 
*******************************
Name: PSU 1
Health: Healthy
Health Details: No details available
Hotswap Status: Active
FRU: Informations are invalid

Name: PSU 2
Health: Healthy
Health Details: No details available
Hotswap Status: Active
FRU: Informations are invalid



*******************************
HubNodes
*******************************

================================
Name: HubNode 1
Health: Healthy
Health Details: 
        Node BMC sensors aggregated for Health Status:
        | Sensor ID | Sensor Name      | Value     | Health                |
         ------------------------------------------------------------------ 
        | 0x0b      | Temp On-Board    | 29.00     | Healthy               |
        | 0x0c      | Temp Eth Switch  | 28.00     | Healthy               |
        | 0x0d      | Temp Quad Phy    | 34.00     | Healthy               |
        | 0x0e      | Temp Inlet       | 22.00     | Healthy               |
        | 0x0f      | Temp Phy 10G     | 51.00     | Healthy               |
        | 0x10      | Vcc +12V In      | 12.18     | Healthy               |
        | 0x11      | Vcc +5V SUS      | 5.08      | Healthy               |
        | 0x12      | Vcc +3.3V SUS    | 3.29      | Healthy               |
        | 0x13      | Vcc +1.8V SUS    | 1.79      | Healthy               |
        | 0x14      | Vcc +1.5V SUS    | 1.50      | Healthy               |
        | 0x15      | Vcc +1.25V SUS   | 1.24      | Healthy               |
        | 0x16      | Vcc +1.2V SUS    | 1.19      | Healthy               |
        | 0x17      | Vcc +0.75V SUS   | 0.75      | Healthy               |
        | 0x18      | Vcc +3.3V        | 3.29      | Healthy               |
        | 0x19      | Vcc +2.5V        | 2.47      | Healthy               |
        | 0x1a      | Vcc +1.8V        | 1.79      | Healthy               |
        | 0x1b      | Vcc +1.2V        | 1.21      | Healthy               |
        | 0x1c      | Vcc +1.0V        | 1.01      | Healthy               |
        | 0x1d      | Vbat +3V         | 3.14      | Healthy               |
        | 0x3f      | Power Good Latch | 0x01 0x80 | Healthy               |
        | 0x40      | FPGA RW Status   | 0x02 0x80 | Healthy               |
        | 0x41      | FPGA Heartbeat   | 0x02 0x80 | Healthy               |
        | 0x48      | ShMC Redun State | 0x02 0x80 | Healthy               |
Hotswap Status: Active
Product name: MSH8900
Part number: T4301X_2-X
Serial number: 9017061685
Manufacturing date: Tue Oct 27 23:23:00 2020
Type: HubNode
Status: Active
Model: MSH8900
HPM versions:
	BMC: 3.20.093AA546
	FPGA: 2.6.00000000
Management Network:
        Management MAC: 00:a0:a5:df:77:b1
        IP Source: static
        IP: 192.168.1.5
        Subnet: 255.255.255.0
        Gateway: 0.0.0.0
        VLAN: 4093
Payload IPs :
	Network Interfaces:
		Id: 1, 
		Backplane: Management, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:df:77:92
		IP Source: static

================================

================================
Name: HubNode 2
Health: Healthy
Health Details: 
        Node BMC sensors aggregated for Health Status:
        | Sensor ID | Sensor Name      | Value     | Health                |
         ------------------------------------------------------------------ 
        | 0x0b      | Temp On-Board    | 29.00     | Healthy               |
        | 0x0c      | Temp Eth Switch  | 29.00     | Healthy               |
        | 0x0d      | Temp Quad Phy    | 35.00     | Healthy               |
        | 0x0e      | Temp Inlet       | 22.00     | Healthy               |
        | 0x0f      | Temp Phy 10G     | 51.00     | Healthy               |
        | 0x10      | Vcc +12V In      | 12.18     | Healthy               |
        | 0x11      | Vcc +5V SUS      | 5.08      | Healthy               |
        | 0x12      | Vcc +3.3V SUS    | 3.29      | Healthy               |
        | 0x13      | Vcc +1.8V SUS    | 1.79      | Healthy               |
        | 0x14      | Vcc +1.5V SUS    | 1.51      | Healthy               |
        | 0x15      | Vcc +1.25V SUS   | 1.24      | Healthy               |
        | 0x16      | Vcc +1.2V SUS    | 1.19      | Healthy               |
        | 0x17      | Vcc +0.75V SUS   | 0.75      | Healthy               |
        | 0x18      | Vcc +3.3V        | 3.29      | Healthy               |
        | 0x19      | Vcc +2.5V        | 2.48      | Healthy               |
        | 0x1a      | Vcc +1.8V        | 1.79      | Healthy               |
        | 0x1b      | Vcc +1.2V        | 1.21      | Healthy               |
        | 0x1c      | Vcc +1.0V        | 1.01      | Healthy               |
        | 0x1d      | Vbat +3V         | 3.14      | Healthy               |
        | 0x3f      | Power Good Latch | 0x01 0x80 | Healthy               |
        | 0x40      | FPGA RW Status   | 0x02 0x80 | Healthy               |
        | 0x41      | FPGA Heartbeat   | 0x02 0x80 | Healthy               |
        | 0x48      | ShMC Redun State | 0x08 0x80 | Healthy               |
Hotswap Status: Active
Product name: MSH8900
Part number: T4301X_2-X
Serial number: 9017061638
Manufacturing date: Wed Oct 28 00:20:00 2020
Type: HubNode
Status: Standby
Model: MSH8900
HPM versions:
	BMC: 3.20.093AA546
	FPGA: 2.6.00000000
Management Network:
        Management MAC: 00:a0:a5:df:78:59
        IP Source: dhcp
        IP: 0.0.0.0
        Subnet: 0.0.0.0
        Gateway: 0.0.0.0
        VLAN: 4093
Payload IPs :
	Network Interfaces:
		Id: 1, 
		Backplane: Management, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:df:78:3a
		IP Source: static

================================

*******************************
Nodes
*******************************

================================
SLOT #1
================================
Name: Node 1
Health: Healthy
Health Details: 
        Node BMC sensors aggregated for Health Status:
        | Sensor ID | Sensor Name      | Value     | Health                |
         ------------------------------------------------------------------ 
        | 0x0e      | Vcc +12V SUS     | 12.12     | Healthy               |
        | 0x0f      | Vcc +5V SUS      | 5.03      | Healthy               |
        | 0x10      | Vcc +2.5V SUS    | 2.48      | Healthy               |
        | 0x11      | Vcc +1.8V SUS    | 1.81      | Healthy               |
        | 0x12      | Vcc +1.5V SUS    | 1.49      | Healthy               |
        | 0x13      | Vcc +1.25V SUS   | 1.24      | Healthy               |
        | 0x14      | Vcc +0.75V SUS   | 0.74      | Healthy               |
        | 0x04      | Temp Inlet       | 22.00     | Healthy               |
        | 0x05      | Temp Outlet      | 23.00     | Healthy               |
        | 0x06      | Temp Vcore       | 22.00     | Healthy               |
        | 0x07      | Temp BMC         | 31.00     | Healthy               |
        | 0x08      | Temp CPU 1       | 0.00      | Healthy               |
        | 0x09      | Temp CPU 2       | 0.00      | Healthy               |
        Payload Specific Health Status (for Nodes with more than 1 payload/mmc):
            Payload 1: Healthy
            Payload 2: Healthy

Hotswap Status: Inactive
Product name: 4009
Part number: 1062-0224
Serial number: 9017062979
Manufacturing date: Mon Nov  9 17:33:00 2020
Type: Node
Model: MSP805x
HPM versions:
	BMC: 1.9.0940E3AB
	FPGA: 1.2.00000000
	BIOS: 1.7.093A4DC4
Management Network:
        Management MAC: 00:a0:a5:df:ac:3a
        IP Source: dhcp
        IP: 0.0.0.0
        Subnet: 0.0.0.0
        Gateway: 0.0.0.0
        VLAN: 4093
Payload IPs :
	Network Interfaces:
		Id: 1, 
		Backplane: Base2, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:df:ac:34
		IP Source: static


		Id: 2, 
		Backplane: Fabric1p1, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:df:ac:35
		IP Source: static


		Id: 3, 
		Backplane: Fabric2p2, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:df:ac:36
		IP Source: static


	Network Interfaces:
		Id: 1, 
		Backplane: Base1, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:df:ac:37
		IP Source: static


		Id: 2, 
		Backplane: Fabric1p2, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:df:ac:38
		IP Source: static


		Id: 3, 
		Backplane: Fabric2p1, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:df:ac:39
		IP Source: static

================================

================================
SLOT #2
================================
Name: Node 2
Health: Healthy
Health Details: 
        Node BMC sensors aggregated for Health Status:
        | Sensor ID | Sensor Name      | Value     | Health                |
         ------------------------------------------------------------------ 
        | 0x0e      | Vcc +12V SUS     | 12.18     | Healthy               |
        | 0x0f      | Vcc +5V SUS      | 5.01      | Healthy               |
        | 0x10      | Vcc +2.5V SUS    | 2.47      | Healthy               |
        | 0x11      | Vcc +1.8V SUS    | 1.81      | Healthy               |
        | 0x12      | Vcc +1.5V SUS    | 1.49      | Healthy               |
        | 0x13      | Vcc +1.25V SUS   | 1.25      | Healthy               |
        | 0x14      | Vcc +0.75V SUS   | 0.75      | Healthy               |
        | 0x04      | Temp Inlet       | 22.00     | Healthy               |
        | 0x05      | Temp Outlet      | 23.00     | Healthy               |
        | 0x06      | Temp Vcore       | 22.00     | Healthy               |
        | 0x07      | Temp BMC         | 30.00     | Healthy               |
        | 0x08      | Temp CPU 1       | 0.00      | Healthy               |
        | 0x09      | Temp CPU 2       | 0.00      | Healthy               |
        Payload Specific Health Status (for Nodes with more than 1 payload/mmc):
            Payload 1: Healthy
            Payload 2: Healthy

Hotswap Status: Inactive
Product name: 4009
Part number: 1062-0224
Serial number: 9017063696
Manufacturing date: Mon Nov  9 18:36:00 2020
Type: Node
Model: MSP805x
HPM versions:
	BMC: 1.9.0940E3AB
	FPGA: 1.2.00000000
	BIOS: 1.7.093A4DC4
Management Network:
        Management MAC: 00:a0:a5:df:ac:c6
        IP Source: dhcp
        IP: 0.0.0.0
        Subnet: 0.0.0.0
        Gateway: 0.0.0.0
        VLAN: 4093
Payload IPs :
	Network Interfaces:
		Id: 1, 
		Backplane: Base2, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:df:ac:c0
		IP Source: static


		Id: 2, 
		Backplane: Fabric1p1, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:df:ac:c1
		IP Source: static


		Id: 3, 
		Backplane: Fabric2p2, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:df:ac:c2
		IP Source: static


	Network Interfaces:
		Id: 1, 
		Backplane: Base1, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:df:ac:c3
		IP Source: static


		Id: 2, 
		Backplane: Fabric1p2, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:df:ac:c4
		IP Source: static


		Id: 3, 
		Backplane: Fabric2p1, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:df:ac:c5
		IP Source: static

================================

================================
SLOT #3
================================
Name: Node 3
Health: Healthy
Health Details: 
        Node BMC sensors aggregated for Health Status:
        | Sensor ID | Sensor Name      | Value     | Health                |
         ------------------------------------------------------------------ 
        | 0x0e      | Vcc +12V SUS     | 12.12     | Healthy               |
        | 0x0f      | Vcc +5V SUS      | 4.98      | Healthy               |
        | 0x10      | Vcc +2.5V SUS    | 2.48      | Healthy               |
        | 0x11      | Vcc +1.8V SUS    | 1.80      | Healthy               |
        | 0x12      | Vcc +1.5V SUS    | 1.49      | Healthy               |
        | 0x13      | Vcc +1.25V SUS   | 1.25      | Healthy               |
        | 0x14      | Vcc +0.75V SUS   | 0.74      | Healthy               |
        | 0x04      | Temp Inlet       | 22.00     | Healthy               |
        | 0x05      | Temp Outlet      | 23.00     | Healthy               |
        | 0x06      | Temp Vcore       | 22.00     | Healthy               |
        | 0x07      | Temp BMC         | 30.00     | Healthy               |
        | 0x08      | Temp CPU 1       | 0.00      | Healthy               |
        | 0x09      | Temp CPU 2       | 0.00      | Healthy               |
        Payload Specific Health Status (for Nodes with more than 1 payload/mmc):
            Payload 1: Healthy
            Payload 2: Healthy

Hotswap Status: Inactive
Product name: 4009
Part number: 1062-0224
Serial number: 9017063709
Manufacturing date: Mon Nov  9 19:47:00 2020
Type: Node
Model: MSP805x
HPM versions:
	BMC: 1.9.0940E3AB
	FPGA: 1.2.00000000
	BIOS: 1.7.093A4DC4
Management Network:
        Management MAC: 00:a0:a5:df:ad:0c
        IP Source: dhcp
        IP: 0.0.0.0
        Subnet: 0.0.0.0
        Gateway: 0.0.0.0
        VLAN: 4093
Payload IPs :
	Network Interfaces:
		Id: 1, 
		Backplane: Base2, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:df:ad:06
		IP Source: static


		Id: 2, 
		Backplane: Fabric1p1, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:df:ad:07
		IP Source: static


		Id: 3, 
		Backplane: Fabric2p2, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:df:ad:08
		IP Source: static


	Network Interfaces:
		Id: 1, 
		Backplane: Base1, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:df:ad:09
		IP Source: static


		Id: 2, 
		Backplane: Fabric1p2, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:df:ad:0a
		IP Source: static


		Id: 3, 
		Backplane: Fabric2p1, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:df:ad:0b
		IP Source: static

================================

================================
SLOT #4
================================
Name: Node 4
Health: Healthy
Health Details: 
        Node BMC sensors aggregated for Health Status:
        | Sensor ID | Sensor Name      | Value     | Health                |
         ------------------------------------------------------------------ 
        | 0x0e      | Vcc +12V SUS     | 12.12     | Healthy               |
        | 0x0f      | Vcc +5V SUS      | 5.03      | Healthy               |
        | 0x10      | Vcc +2.5V SUS    | 2.48      | Healthy               |
        | 0x11      | Vcc +1.8V SUS    | 1.81      | Healthy               |
        | 0x12      | Vcc +1.5V SUS    | 1.50      | Healthy               |
        | 0x13      | Vcc +1.25V SUS   | 1.25      | Healthy               |
        | 0x14      | Vcc +0.75V SUS   | 0.75      | Healthy               |
        | 0x04      | Temp Inlet       | 22.00     | Healthy               |
        | 0x05      | Temp Outlet      | 23.00     | Healthy               |
        | 0x06      | Temp Vcore       | 22.00     | Healthy               |
        | 0x07      | Temp BMC         | 30.00     | Healthy               |
        | 0x08      | Temp CPU 1       | 0.00      | Healthy               |
        | 0x09      | Temp CPU 2       | 0.00      | Healthy               |
        Payload Specific Health Status (for Nodes with more than 1 payload/mmc):
            Payload 1: Healthy
            Payload 2: Healthy

Hotswap Status: Inactive
Product name: 4009
Part number: 1062-0224
Serial number: 9017063562
Manufacturing date: Fri Nov  6 21:15:00 2020
Type: Node
Model: MSP805x
HPM versions:
	BMC: 1.9.0940E3AB
	FPGA: 1.2.00000000
	BIOS: 1.7.093A4DC4
Management Network:
        Management MAC: 00:a0:a5:df:a5:da
        IP Source: dhcp
        IP: 0.0.0.0
        Subnet: 0.0.0.0
        Gateway: 0.0.0.0
        VLAN: 4093
Payload IPs :
	Network Interfaces:
		Id: 1, 
		Backplane: Base2, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:df:a5:d4
		IP Source: static


		Id: 2, 
		Backplane: Fabric1p1, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:df:a5:d5
		IP Source: static


		Id: 3, 
		Backplane: Fabric2p2, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:df:a5:d6
		IP Source: static


	Network Interfaces:
		Id: 1, 
		Backplane: Base1, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:df:a5:d7
		IP Source: static


		Id: 2, 
		Backplane: Fabric1p2, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:df:a5:d8
		IP Source: static


		Id: 3, 
		Backplane: Fabric2p1, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:df:a5:d9
		IP Source: static

================================

================================
SLOT #5
================================
Name: Node 5
Health: Healthy
Health Details: 
        Node BMC sensors aggregated for Health Status:
        | Sensor ID | Sensor Name      | Value     | Health                |
         ------------------------------------------------------------------ 
        | 0x0e      | Vcc +12V SUS     | 12.12     | Healthy               |
        | 0x0f      | Vcc +5V SUS      | 5.01      | Healthy               |
        | 0x10      | Vcc +2.5V SUS    | 2.50      | Healthy               |
        | 0x11      | Vcc +1.8V SUS    | 1.80      | Healthy               |
        | 0x12      | Vcc +1.5V SUS    | 1.49      | Healthy               |
        | 0x13      | Vcc +1.25V SUS   | 1.25      | Healthy               |
        | 0x14      | Vcc +0.75V SUS   | 0.75      | Healthy               |
        | 0x04      | Temp Inlet       | 21.00     | Healthy               |
        | 0x05      | Temp Outlet      | 23.00     | Healthy               |
        | 0x06      | Temp Vcore       | 22.00     | Healthy               |
        | 0x07      | Temp BMC         | 30.00     | Healthy               |
        | 0x08      | Temp CPU 1       | 0.00      | Healthy               |
        | 0x09      | Temp CPU 2       | 0.00      | Healthy               |
        Payload Specific Health Status (for Nodes with more than 1 payload/mmc):
            Payload 1: Healthy
            Payload 2: Healthy

Hotswap Status: Inactive
Product name: 4009
Part number: 1062-0224
Serial number: 9017063520
Manufacturing date: Mon Nov  9 21:22:00 2020
Type: Node
Model: MSP805x
HPM versions:
	BMC: 1.9.0940E3AB
	FPGA: 1.2.00000000
	BIOS: 1.7.093A4DC4
Management Network:
        Management MAC: 00:a0:a5:df:ad:f8
        IP Source: dhcp
        IP: 0.0.0.0
        Subnet: 0.0.0.0
        Gateway: 0.0.0.0
        VLAN: 4093
Payload IPs :
	Network Interfaces:
		Id: 1, 
		Backplane: Base2, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:df:ad:f2
		IP Source: static


		Id: 2, 
		Backplane: Fabric1p1, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:df:ad:f3
		IP Source: static


		Id: 3, 
		Backplane: Fabric2p2, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:df:ad:f4
		IP Source: static


	Network Interfaces:
		Id: 1, 
		Backplane: Base1, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:df:ad:f5
		IP Source: static


		Id: 2, 
		Backplane: Fabric1p2, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:df:ad:f6
		IP Source: static


		Id: 3, 
		Backplane: Fabric2p1, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:df:ad:f7
		IP Source: static

================================

================================
SLOT #6
================================
Name: Node 6
Health: Healthy
Health Details: 
        Node BMC sensors aggregated for Health Status:
        | Sensor ID | Sensor Name      | Value     | Health                |
         ------------------------------------------------------------------ 
        | 0x0e      | Vcc +12V SUS     | 12.12     | Healthy               |
        | 0x0f      | Vcc +5V SUS      | 5.01      | Healthy               |
        | 0x10      | Vcc +2.5V SUS    | 2.48      | Healthy               |
        | 0x11      | Vcc +1.8V SUS    | 1.81      | Healthy               |
        | 0x12      | Vcc +1.5V SUS    | 1.50      | Healthy               |
        | 0x13      | Vcc +1.25V SUS   | 1.24      | Healthy               |
        | 0x14      | Vcc +0.75V SUS   | 0.74      | Healthy               |
        | 0x04      | Temp Inlet       | 21.00     | Healthy               |
        | 0x05      | Temp Outlet      | 23.00     | Healthy               |
        | 0x06      | Temp Vcore       | 21.00     | Healthy               |
        | 0x07      | Temp BMC         | 30.00     | Healthy               |
        | 0x08      | Temp CPU 1       | 0.00      | Healthy               |
        | 0x09      | Temp CPU 2       | 0.00      | Healthy               |
        Payload Specific Health Status (for Nodes with more than 1 payload/mmc):
            Payload 1: Healthy
            Payload 2: Healthy

Hotswap Status: Inactive
Product name: 4009
Part number: 1062-0224
Serial number: 9017062739
Manufacturing date: Tue Nov 10 00:20:00 2020
Type: Node
Model: MSP805x
HPM versions:
	BMC: 1.9.0940E3AB
	FPGA: 1.2.00000000
	BIOS: 1.7.093A4DC4
Management Network:
        Management MAC: 00:a0:a5:df:ad:c8
        IP Source: dhcp
        IP: 0.0.0.0
        Subnet: 0.0.0.0
        Gateway: 0.0.0.0
        VLAN: 4093
Payload IPs :
	Network Interfaces:
		Id: 1, 
		Backplane: Base2, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:df:ad:c2
		IP Source: static


		Id: 2, 
		Backplane: Fabric1p1, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:df:ad:c3
		IP Source: static


		Id: 3, 
		Backplane: Fabric2p2, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:df:ad:c4
		IP Source: static


	Network Interfaces:
		Id: 1, 
		Backplane: Base1, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:df:ad:c5
		IP Source: static


		Id: 2, 
		Backplane: Fabric1p2, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:df:ad:c6
		IP Source: static


		Id: 3, 
		Backplane: Fabric2p1, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:df:ad:c7
		IP Source: static

================================

================================
SLOT #7
================================
Name: Node 7
Health: Healthy
Health Details: 
        Node BMC sensors aggregated for Health Status:
        | Sensor ID | Sensor Name      | Value     | Health                |
         ------------------------------------------------------------------ 
        | 0x0e      | Vcc +12V SUS     | 12.12     | Healthy               |
        | 0x0f      | Vcc +5V SUS      | 5.01      | Healthy               |
        | 0x10      | Vcc +2.5V SUS    | 2.48      | Healthy               |
        | 0x11      | Vcc +1.8V SUS    | 1.80      | Healthy               |
        | 0x12      | Vcc +1.5V SUS    | 1.49      | Healthy               |
        | 0x13      | Vcc +1.25V SUS   | 1.25      | Healthy               |
        | 0x14      | Vcc +0.75V SUS   | 0.76      | Healthy               |
        | 0x04      | Temp Inlet       | 22.00     | Healthy               |
        | 0x05      | Temp Outlet      | 23.00     | Healthy               |
        | 0x06      | Temp Vcore       | 22.00     | Healthy               |
        | 0x07      | Temp BMC         | 30.00     | Healthy               |
        | 0x08      | Temp CPU 1       | 0.00      | Healthy               |
        | 0x09      | Temp CPU 2       | 0.00      | Healthy               |
        Payload Specific Health Status (for Nodes with more than 1 payload/mmc):
            Payload 1: Healthy
            Payload 2: Healthy

Hotswap Status: Inactive
Product name: 4009
Part number: 1062-0224
Serial number: 9017063430
Manufacturing date: Fri Nov  6 18:25:00 2020
Type: Node
Model: MSP805x
HPM versions:
	BMC: 1.9.0940E3AB
	FPGA: 1.2.00000000
	BIOS: 1.7.093A4DC4
Management Network:
        Management MAC: 00:a0:a5:df:a4:62
        IP Source: dhcp
        IP: 0.0.0.0
        Subnet: 0.0.0.0
        Gateway: 0.0.0.0
        VLAN: 4093
Payload IPs :
	Network Interfaces:
		Id: 1, 
		Backplane: Base2, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:df:a4:5c
		IP Source: static


		Id: 2, 
		Backplane: Fabric1p1, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:df:a4:5d
		IP Source: static


		Id: 3, 
		Backplane: Fabric2p2, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:df:a4:5e
		IP Source: static


	Network Interfaces:
		Id: 1, 
		Backplane: Base1, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:df:a4:5f
		IP Source: static


		Id: 2, 
		Backplane: Fabric1p2, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:df:a4:60
		IP Source: static


		Id: 3, 
		Backplane: Fabric2p1, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:df:a4:61
		IP Source: static

================================

================================
SLOT #8
================================
Name: Node 8
Health: Healthy
Health Details: 
        Node BMC sensors aggregated for Health Status:
        | Sensor ID | Sensor Name      | Value     | Health                |
         ------------------------------------------------------------------ 
        | 0x0e      | Vcc +12V SUS     | 12.18     | Healthy               |
        | 0x0f      | Vcc +5V SUS      | 5.03      | Healthy               |
        | 0x10      | Vcc +2.5V SUS    | 2.49      | Healthy               |
        | 0x11      | Vcc +1.8V SUS    | 1.80      | Healthy               |
        | 0x12      | Vcc +1.5V SUS    | 1.49      | Healthy               |
        | 0x13      | Vcc +1.25V SUS   | 1.24      | Healthy               |
        | 0x14      | Vcc +0.75V SUS   | 0.75      | Healthy               |
        | 0x04      | Temp Inlet       | 21.00     | Healthy               |
        | 0x05      | Temp Outlet      | 23.00     | Healthy               |
        | 0x06      | Temp Vcore       | 21.00     | Healthy               |
        | 0x07      | Temp BMC         | 29.00     | Healthy               |
        | 0x08      | Temp CPU 1       | 0.00      | Healthy               |
        | 0x09      | Temp CPU 2       | 0.00      | Healthy               |
        Payload Specific Health Status (for Nodes with more than 1 payload/mmc):
            Payload 1: Healthy
            Payload 2: Healthy

Hotswap Status: Inactive
Product name: 4009
Part number: 1062-0224
Serial number: 9017063563
Manufacturing date: Mon Nov  9 19:15:00 2020
Type: Node
Model: MSP805x
HPM versions:
	BMC: 1.9.0940E3AB
	FPGA: 1.2.00000000
	BIOS: 1.7.093A4DC4
Management Network:
        Management MAC: 00:a0:a5:df:ac:62
        IP Source: dhcp
        IP: 0.0.0.0
        Subnet: 0.0.0.0
        Gateway: 0.0.0.0
        VLAN: 4093
Payload IPs :
	Network Interfaces:
		Id: 1, 
		Backplane: Base2, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:df:ac:5c
		IP Source: static


		Id: 2, 
		Backplane: Fabric1p1, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:df:ac:5d
		IP Source: static


		Id: 3, 
		Backplane: Fabric2p2, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:df:ac:5e
		IP Source: static


	Network Interfaces:
		Id: 1, 
		Backplane: Base1, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:df:ac:5f
		IP Source: static


		Id: 2, 
		Backplane: Fabric1p2, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:df:ac:60
		IP Source: static


		Id: 3, 
		Backplane: Fabric2p1, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:df:ac:61
		IP Source: static

================================

================================
SLOT #9
================================
Name: Node 9
Health: Healthy
Health Details: 
        Node BMC sensors aggregated for Health Status:
        | Sensor ID | Sensor Name      | Value     | Health                |
         ------------------------------------------------------------------ 
        | 0x0e      | Vcc +12V SUS     | 12.12     | Healthy               |
        | 0x0f      | Vcc +5V SUS      | 4.93      | Healthy               |
        | 0x10      | Vcc +2.5V SUS    | 2.47      | Healthy               |
        | 0x11      | Vcc +1.8V SUS    | 1.80      | Healthy               |
        | 0x12      | Vcc +1.5V SUS    | 1.50      | Healthy               |
        | 0x13      | Vcc +1.25V SUS   | 1.26      | Healthy               |
        | 0x14      | Vcc +0.75V SUS   | 0.74      | Healthy               |
        | 0x04      | Temp Inlet       | 21.00     | Healthy               |
        | 0x05      | Temp Outlet      | 23.00     | Healthy               |
        | 0x06      | Temp Vcore       | 22.00     | Healthy               |
        | 0x07      | Temp BMC         | 30.00     | Healthy               |
        | 0x08      | Temp CPU 1       | 0.00      | Healthy               |
        | 0x09      | Temp CPU 2       | 0.00      | Healthy               |
        Payload Specific Health Status (for Nodes with more than 1 payload/mmc):
            Payload 1: Healthy
            Payload 2: Healthy

Hotswap Status: Inactive
Product name: 4009
Part number: 1062-0224
Serial number: 9017063619
Manufacturing date: Mon Nov  9 20:48:00 2020
Type: Node
Model: MSP805x
HPM versions:
	BMC: 1.9.0940E3AB
	FPGA: 1.2.00000000
	BIOS: 1.7.093A4DC4
Management Network:
        Management MAC: 00:a0:a5:df:ad:60
        IP Source: dhcp
        IP: 0.0.0.0
        Subnet: 0.0.0.0
        Gateway: 0.0.0.0
        VLAN: 4093
Payload IPs :
	Network Interfaces:
		Id: 1, 
		Backplane: Base2, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:df:ad:5a
		IP Source: static


		Id: 2, 
		Backplane: Fabric1p1, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:df:ad:5b
		IP Source: static


		Id: 3, 
		Backplane: Fabric2p2, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:df:ad:5c
		IP Source: static


	Network Interfaces:
		Id: 1, 
		Backplane: Base1, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:df:ad:5d
		IP Source: static


		Id: 2, 
		Backplane: Fabric1p2, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:df:ad:5e
		IP Source: static


		Id: 3, 
		Backplane: Fabric2p1, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:df:ad:5f
		IP Source: static

================================

*******************************
Original JSON string
*******************************
{ "name": "Platform #1", "number": "1", "chassis": "ms2900", "health": "Green", "fans":[ {"number": "1", "name": "Fan 1", "type": "fan", "health": "Green", "rpm": "8239","alarm": {"alarmlevel": "None"}, "LedIdentify": {"status": "off"}, "hotswapStatus":{"state": "M4", "text": "Active"}}, {"number": "2", "name": "Fan 2", "type": "fan", "health": "Green", "rpm": "8316","alarm": {"alarmlevel": "None"}, "LedIdentify": {"status": "off"}, "hotswapStatus":{"state": "M4", "text": "Active"}}, {"number": "3", "name": "Fan 3", "type": "fan", "health": "Green", "rpm": "8393","alarm": {"alarmlevel": "None"}, "LedIdentify": {"status": "off"}, "hotswapStatus":{"state": "M4", "text": "Active"}}, {"number": "4", "name": "Fan 4", "type": "fan", "health": "Green", "rpm": "8393","alarm": {"alarmlevel": "None"}, "LedIdentify": {"status": "off"}, "hotswapStatus":{"state": "M4", "text": "Active"}}, {"number": "5", "name": "Fan 5", "type": "fan", "health": "Green", "rpm": "8393","alarm": {"alarmlevel": "None"}, "LedIdentify": {"status": "off"}, "hotswapStatus":{"state": "M4", "text": "Active"}} ], "type": "platform", "components": [{"number": "10", "name": "HubNode 1", "health": "Green", "fruInfo": {"mfgDate": "Tue Oct 27 23:23:00 2020", "boardMfg": "Kontron", "boardProductName": "MSH8900", "boardProductPart": "T4301X_2-X", "boardSerialNumber": "9017061685"},"hotswapStatus":{"state": "M4", "text": "Active"},"type":"hubnode", "HubNodeFeatures":{"SwitchSpeedSupport": "1", "PortModeSupport": "0"}, "versions" : [{ "name" : "BMC", "major" : "3", "minor" : "20", "revision" : "093AA546"},{ "name" : "FPGA", "major" : "2", "minor" : "06", "revision" : "00000000"}],"model": "MSH8900", "isUpdating" : "0", "managementIP": "192.168.1.5", "managementMAC": "00:a0:a5:df:77:b1", "alarm": {"alarmlevel": "None", "sensors":[]}, "LedIdentify": {"status": "off"}, "components": [{ "description": "Switch 1", "number": "1", "hotswapStatus":{"state": "M4", "text": "Active"}, "health": "Green", "networkInterfaces": [{ "id": "1", "backplane": "Management", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:df:77:92"}]}], "status": "Active"}, {"number": "11", "name": "HubNode 2", "health": "Green", "fruInfo": {"mfgDate": "Wed Oct 28 00:20:00 2020", "boardMfg": "Kontron", "boardProductName": "MSH8900", "boardProductPart": "T4301X_2-X", "boardSerialNumber": "9017061638"},"hotswapStatus":{"state": "M4", "text": "Active"},"type":"hubnode", "HubNodeFeatures":{"SwitchSpeedSupport": "1", "PortModeSupport": "0"}, "versions" : [{ "name" : "BMC", "major" : "3", "minor" : "20", "revision" : "093AA546"},{ "name" : "FPGA", "major" : "2", "minor" : "06", "revision" : "00000000"}],"model": "MSH8900", "isUpdating" : "0", "managementIP": "0.0.0.0", "managementMAC": "00:a0:a5:df:78:59", "alarm": {"alarmlevel": "None", "sensors":[]}, "LedIdentify": {"status": "off"}, "components": [{ "description": "Switch 2", "number": "1", "hotswapStatus":{"state": "M4", "text": "Active"}, "health": "Green", "networkInterfaces": [{ "id": "1", "backplane": "Management", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:df:78:3a"}]}], "status": "Standby"}, {"number": "1", "name": "Node 1", "health": "Green", "fruInfo": {"mfgDate": "Mon Nov  9 17:33:00 2020", "boardMfg": "Kontron", "boardProductName": "4009", "boardProductPart": "1062-0224", "boardSerialNumber": "9017062979"},"hotswapStatus":{"state": "M1", "text": "Inactive"},"type":"node", "versions" : [{ "name" : "BMC", "major" : "1", "minor" : "09", "revision" : "0940E3AB"},{ "name" : "FPGA", "major" : "1", "minor" : "02", "revision" : "00000000"},{ "name" : "BIOS", "major" : "1", "minor" : "07", "revision" : "093A4DC4"}],"model": "MSP805x", "isUpdating" : "0", "managementIP": "0.0.0.0", "managementMAC": "00:a0:a5:df:ac:3a", "alarm": {"alarmlevel": "None", "sensors":[]}, "LedIdentify": {"status": "off"}, "components": [{ "description": "Payload1       ", "number": "1", "hotswapStatus":{"state": "M1", "text": "Inactive"}, "health": "Green", "networkInterfaces": [{ "id": "1", "backplane": "Base2", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:df:ac:34"}, { "id": "2", "backplane": "Fabric1p1", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:df:ac:35"}, { "id": "3", "backplane": "Fabric2p2", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:df:ac:36"}]}, { "description": "Payload2       ", "number": "2", "hotswapStatus":{"state": "M1", "text": "Inactive"}, "health": "Green", "networkInterfaces": [{ "id": "1", "backplane": "Base1", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:df:ac:37"}, { "id": "2", "backplane": "Fabric1p2", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:df:ac:38"}, { "id": "3", "backplane": "Fabric2p1", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:df:ac:39"}]}] }, {"number": "2", "name": "Node 2", "health": "Green", "fruInfo": {"mfgDate": "Mon Nov  9 18:36:00 2020", "boardMfg": "Kontron", "boardProductName": "4009", "boardProductPart": "1062-0224", "boardSerialNumber": "9017063696"},"hotswapStatus":{"state": "M1", "text": "Inactive"},"type":"node", "versions" : [{ "name" : "BMC", "major" : "1", "minor" : "09", "revision" : "0940E3AB"},{ "name" : "FPGA", "major" : "1", "minor" : "02", "revision" : "00000000"},{ "name" : "BIOS", "major" : "1", "minor" : "07", "revision" : "093A4DC4"}],"model": "MSP805x", "isUpdating" : "0", "managementIP": "0.0.0.0", "managementMAC": "00:a0:a5:df:ac:c6", "alarm": {"alarmlevel": "None", "sensors":[]}, "LedIdentify": {"status": "off"}, "components": [{ "description": "Payload1       ", "number": "1", "hotswapStatus":{"state": "M1", "text": "Inactive"}, "health": "Green", "networkInterfaces": [{ "id": "1", "backplane": "Base2", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:df:ac:c0"}, { "id": "2", "backplane": "Fabric1p1", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:df:ac:c1"}, { "id": "3", "backplane": "Fabric2p2", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:df:ac:c2"}]}, { "description": "Payload2       ", "number": "2", "hotswapStatus":{"state": "M1", "text": "Inactive"}, "health": "Green", "networkInterfaces": [{ "id": "1", "backplane": "Base1", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:df:ac:c3"}, { "id": "2", "backplane": "Fabric1p2", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:df:ac:c4"}, { "id": "3", "backplane": "Fabric2p1", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:df:ac:c5"}]}] }, {"number": "3", "name": "Node 3", "health": "Green", "fruInfo": {"mfgDate": "Mon Nov  9 19:47:00 2020", "boardMfg": "Kontron", "boardProductName": "4009", "boardProductPart": "1062-0224", "boardSerialNumber": "9017063709"},"hotswapStatus":{"state": "M1", "text": "Inactive"},"type":"node", "versions" : [{ "name" : "BMC", "major" : "1", "minor" : "09", "revision" : "0940E3AB"},{ "name" : "FPGA", "major" : "1", "minor" : "02", "revision" : "00000000"},{ "name" : "BIOS", "major" : "1", "minor" : "07", "revision" : "093A4DC4"}],"model": "MSP805x", "isUpdating" : "0", "managementIP": "0.0.0.0", "managementMAC": "00:a0:a5:df:ad:0c", "alarm": {"alarmlevel": "None", "sensors":[]}, "LedIdentify": {"status": "off"}, "components": [{ "description": "Payload1       ", "number": "1", "hotswapStatus":{"state": "M1", "text": "Inactive"}, "health": "Green", "networkInterfaces": [{ "id": "1", "backplane": "Base2", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:df:ad:06"}, { "id": "2", "backplane": "Fabric1p1", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:df:ad:07"}, { "id": "3", "backplane": "Fabric2p2", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:df:ad:08"}]}, { "description": "Payload2       ", "number": "2", "hotswapStatus":{"state": "M1", "text": "Inactive"}, "health": "Green", "networkInterfaces": [{ "id": "1", "backplane": "Base1", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:df:ad:09"}, { "id": "2", "backplane": "Fabric1p2", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:df:ad:0a"}, { "id": "3", "backplane": "Fabric2p1", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:df:ad:0b"}]}] }, {"number": "4", "name": "Node 4", "health": "Green", "fruInfo": {"mfgDate": "Fri Nov  6 21:15:00 2020", "boardMfg": "Kontron", "boardProductName": "4009", "boardProductPart": "1062-0224", "boardSerialNumber": "9017063562"},"hotswapStatus":{"state": "M1", "text": "Inactive"},"type":"node", "versions" : [{ "name" : "BMC", "major" : "1", "minor" : "09", "revision" : "0940E3AB"},{ "name" : "FPGA", "major" : "1", "minor" : "02", "revision" : "00000000"},{ "name" : "BIOS", "major" : "1", "minor" : "07", "revision" : "093A4DC4"}],"model": "MSP805x", "isUpdating" : "0", "managementIP": "0.0.0.0", "managementMAC": "00:a0:a5:df:a5:da", "alarm": {"alarmlevel": "None", "sensors":[]}, "LedIdentify": {"status": "off"}, "components": [{ "description": "Payload1       ", "number": "1", "hotswapStatus":{"state": "M1", "text": "Inactive"}, "health": "Green", "networkInterfaces": [{ "id": "1", "backplane": "Base2", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:df:a5:d4"}, { "id": "2", "backplane": "Fabric1p1", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:df:a5:d5"}, { "id": "3", "backplane": "Fabric2p2", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:df:a5:d6"}]}, { "description": "Payload2       ", "number": "2", "hotswapStatus":{"state": "M1", "text": "Inactive"}, "health": "Green", "networkInterfaces": [{ "id": "1", "backplane": "Base1", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:df:a5:d7"}, { "id": "2", "backplane": "Fabric1p2", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:df:a5:d8"}, { "id": "3", "backplane": "Fabric2p1", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:df:a5:d9"}]}] }, {"number": "5", "name": "Node 5", "health": "Green", "fruInfo": {"mfgDate": "Mon Nov  9 21:22:00 2020", "boardMfg": "Kontron", "boardProductName": "4009", "boardProductPart": "1062-0224", "boardSerialNumber": "9017063520"},"hotswapStatus":{"state": "M1", "text": "Inactive"},"type":"node", "versions" : [{ "name" : "BMC", "major" : "1", "minor" : "09", "revision" : "0940E3AB"},{ "name" : "FPGA", "major" : "1", "minor" : "02", "revision" : "00000000"},{ "name" : "BIOS", "major" : "1", "minor" : "07", "revision" : "093A4DC4"}],"model": "MSP805x", "isUpdating" : "0", "managementIP": "0.0.0.0", "managementMAC": "00:a0:a5:df:ad:f8", "alarm": {"alarmlevel": "None", "sensors":[]}, "LedIdentify": {"status": "off"}, "components": [{ "description": "Payload1       ", "number": "1", "hotswapStatus":{"state": "M1", "text": "Inactive"}, "health": "Green", "networkInterfaces": [{ "id": "1", "backplane": "Base2", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:df:ad:f2"}, { "id": "2", "backplane": "Fabric1p1", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:df:ad:f3"}, { "id": "3", "backplane": "Fabric2p2", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:df:ad:f4"}]}, { "description": "Payload2       ", "number": "2", "hotswapStatus":{"state": "M1", "text": "Inactive"}, "health": "Green", "networkInterfaces": [{ "id": "1", "backplane": "Base1", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:df:ad:f5"}, { "id": "2", "backplane": "Fabric1p2", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:df:ad:f6"}, { "id": "3", "backplane": "Fabric2p1", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:df:ad:f7"}]}] }, {"number": "6", "name": "Node 6", "health": "Green", "fruInfo": {"mfgDate": "Tue Nov 10 00:20:00 2020", "boardMfg": "Kontron", "boardProductName": "4009", "boardProductPart": "1062-0224", "boardSerialNumber": "9017062739"},"hotswapStatus":{"state": "M1", "text": "Inactive"},"type":"node", "versions" : [{ "name" : "BMC", "major" : "1", "minor" : "09", "revision" : "0940E3AB"},{ "name" : "FPGA", "major" : "1", "minor" : "02", "revision" : "00000000"},{ "name" : "BIOS", "major" : "1", "minor" : "07", "revision" : "093A4DC4"}],"model": "MSP805x", "isUpdating" : "0", "managementIP": "0.0.0.0", "managementMAC": "00:a0:a5:df:ad:c8", "alarm": {"alarmlevel": "None", "sensors":[]}, "LedIdentify": {"status": "off"}, "components": [{ "description": "Payload1       ", "number": "1", "hotswapStatus":{"state": "M1", "text": "Inactive"}, "health": "Green", "networkInterfaces": [{ "id": "1", "backplane": "Base2", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:df:ad:c2"}, { "id": "2", "backplane": "Fabric1p1", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:df:ad:c3"}, { "id": "3", "backplane": "Fabric2p2", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:df:ad:c4"}]}, { "description": "Payload2       ", "number": "2", "hotswapStatus":{"state": "M1", "text": "Inactive"}, "health": "Green", "networkInterfaces": [{ "id": "1", "backplane": "Base1", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:df:ad:c5"}, { "id": "2", "backplane": "Fabric1p2", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:df:ad:c6"}, { "id": "3", "backplane": "Fabric2p1", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:df:ad:c7"}]}] }, {"number": "7", "name": "Node 7", "health": "Green", "fruInfo": {"mfgDate": "Fri Nov  6 18:25:00 2020", "boardMfg": "Kontron", "boardProductName": "4009", "boardProductPart": "1062-0224", "boardSerialNumber": "9017063430"},"hotswapStatus":{"state": "M1", "text": "Inactive"},"type":"node", "versions" : [{ "name" : "BMC", "major" : "1", "minor" : "09", "revision" : "0940E3AB"},{ "name" : "FPGA", "major" : "1", "minor" : "02", "revision" : "00000000"},{ "name" : "BIOS", "major" : "1", "minor" : "07", "revision" : "093A4DC4"}],"model": "MSP805x", "isUpdating" : "0", "managementIP": "0.0.0.0", "managementMAC": "00:a0:a5:df:a4:62", "alarm": {"alarmlevel": "None", "sensors":[]}, "LedIdentify": {"status": "off"}, "components": [{ "description": "Payload1       ", "number": "1", "hotswapStatus":{"state": "M1", "text": "Inactive"}, "health": "Green", "networkInterfaces": [{ "id": "1", "backplane": "Base2", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:df:a4:5c"}, { "id": "2", "backplane": "Fabric1p1", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:df:a4:5d"}, { "id": "3", "backplane": "Fabric2p2", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:df:a4:5e"}]}, { "description": "Payload2       ", "number": "2", "hotswapStatus":{"state": "M1", "text": "Inactive"}, "health": "Green", "networkInterfaces": [{ "id": "1", "backplane": "Base1", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:df:a4:5f"}, { "id": "2", "backplane": "Fabric1p2", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:df:a4:60"}, { "id": "3", "backplane": "Fabric2p1", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:df:a4:61"}]}] }, {"number": "8", "name": "Node 8", "health": "Green", "fruInfo": {"mfgDate": "Mon Nov  9 19:15:00 2020", "boardMfg": "Kontron", "boardProductName": "4009", "boardProductPart": "1062-0224", "boardSerialNumber": "9017063563"},"hotswapStatus":{"state": "M1", "text": "Inactive"},"type":"node", "versions" : [{ "name" : "BMC", "major" : "1", "minor" : "09", "revision" : "0940E3AB"},{ "name" : "FPGA", "major" : "1", "minor" : "02", "revision" : "00000000"},{ "name" : "BIOS", "major" : "1", "minor" : "07", "revision" : "093A4DC4"}],"model": "MSP805x", "isUpdating" : "0", "managementIP": "0.0.0.0", "managementMAC": "00:a0:a5:df:ac:62", "alarm": {"alarmlevel": "None", "sensors":[]}, "LedIdentify": {"status": "off"}, "components": [{ "description": "Payload1       ", "number": "1", "hotswapStatus":{"state": "M1", "text": "Inactive"}, "health": "Green", "networkInterfaces": [{ "id": "1", "backplane": "Base2", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:df:ac:5c"}, { "id": "2", "backplane": "Fabric1p1", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:df:ac:5d"}, { "id": "3", "backplane": "Fabric2p2", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:df:ac:5e"}]}, { "description": "Payload2       ", "number": "2", "hotswapStatus":{"state": "M1", "text": "Inactive"}, "health": "Green", "networkInterfaces": [{ "id": "1", "backplane": "Base1", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:df:ac:5f"}, { "id": "2", "backplane": "Fabric1p2", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:df:ac:60"}, { "id": "3", "backplane": "Fabric2p1", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:df:ac:61"}]}] }, {"number": "9", "name": "Node 9", "health": "Green", "fruInfo": {"mfgDate": "Mon Nov  9 20:48:00 2020", "boardMfg": "Kontron", "boardProductName": "4009", "boardProductPart": "1062-0224", "boardSerialNumber": "9017063619"},"hotswapStatus":{"state": "M1", "text": "Inactive"},"type":"node", "versions" : [{ "name" : "BMC", "major" : "1", "minor" : "09", "revision" : "0940E3AB"},{ "name" : "FPGA", "major" : "1", "minor" : "02", "revision" : "00000000"},{ "name" : "BIOS", "major" : "1", "minor" : "07", "revision" : "093A4DC4"}],"model": "MSP805x", "isUpdating" : "0", "managementIP": "0.0.0.0", "managementMAC": "00:a0:a5:df:ad:60", "alarm": {"alarmlevel": "None", "sensors":[]}, "LedIdentify": {"status": "off"}, "components": [{ "description": "Payload1       ", "number": "1", "hotswapStatus":{"state": "M1", "text": "Inactive"}, "health": "Green", "networkInterfaces": [{ "id": "1", "backplane": "Base2", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:df:ad:5a"}, { "id": "2", "backplane": "Fabric1p1", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:df:ad:5b"}, { "id": "3", "backplane": "Fabric2p2", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:df:ad:5c"}]}, { "description": "Payload2       ", "number": "2", "hotswapStatus":{"state": "M1", "text": "Inactive"}, "health": "Green", "networkInterfaces": [{ "id": "1", "backplane": "Base1", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:df:ad:5d"}, { "id": "2", "backplane": "Fabric1p2", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:df:ad:5e"}, { "id": "3", "backplane": "Fabric2p1", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:df:ad:5f"}]}] }, { "name": "PSU", "components": [{"id": "PSU1", "number": "1", "name": "Power Supply 1", "health": "Green", "type": "psu", "hotswapStatus":{"state": "M4", "text": "Active"},"alarm": {"alarmlevel": "None"}, "tempInlet": "20.00", "tempOutlet": "24.00", "vIn": "213.00", "powerOut": "48", "powerScale": "1400","peakConsumption": "48", "averageConsumption": "48"},{"id": "PSU2", "number": "2", "name": "Power Supply 2", "health": "Green", "type": "psu", "hotswapStatus":{"state": "M4", "text": "Active"},"alarm": {"alarmlevel": "None"}, "tempInlet": "19.00", "tempOutlet": "24.00", "vIn": "214.00", "powerOut": "32", "powerScale": "1400","peakConsumption": "32", "averageConsumption": "32"}]}], "switchOID": {"oid": "1.3.6.1.4.1.6603"}, "alarm": {"alarmlevel": "None",  "components" : [ {"nodes" : [] } , {"psu" : [] }, {"fans" : [] }], "text": ""}, "LedIdentify": {"status": "off"}}