System informations
*******************************
Name: SYMKLOUD
chassis: ms2900
Health: Healthy
*******************************
Fans: 
*******************************
Fan 1: 
	Present :true
	Status :Healthy
	8162 RPM
Fan 2: 
	Present :true
	Status :Healthy
	8085 RPM
Fan 3: 
	Present :true
	Status :Healthy
	8162 RPM
Fan 4: 
	Present :true
	Status :Healthy
	8316 RPM
Fan 5: 
	Present :true
	Status :Healthy
	8162 RPM


*******************************
PSU: 
*******************************
Name: PSU 1
Health: Healthy
Health Details: No details available
Hotswap Status: Active
FRU: Informations are invalid

Name: PSU 2
Health: Healthy
Health Details: No details available
Hotswap Status: Active
FRU: Informations are invalid



*******************************
HubNodes
*******************************

================================
Name: HubNode 1
Health: Healthy
Health Details: 
        | Sensor ID | Sensor Name      | Value   | Health                |
         ---------------------------------------------------------------- 
        | 0x0b      | Temp On-Board    | 32.00   | Healthy               |
        | 0x0c      | Temp Eth Switch  | 32.00   | Healthy               |
        | 0x0d      | Temp Quad Phy    | 38.00   | Healthy               |
        | 0x0e      | Temp Inlet       | 24.00   | Healthy               |
        | 0x0f      | Temp Phy 10G     | 54.00   | Healthy               |
        | 0x10      | Vcc +12V In      | 12.12   | Healthy               |
        | 0x11      | Vcc +5V SUS      | 5.05    | Healthy               |
        | 0x12      | Vcc +3.3V SUS    | 3.29    | Healthy               |
        | 0x13      | Vcc +1.8V SUS    | 1.78    | Healthy               |
        | 0x14      | Vcc +1.5V SUS    | 1.50    | Healthy               |
        | 0x15      | Vcc +1.25V SUS   | 1.25    | Healthy               |
        | 0x16      | Vcc +1.2V SUS    | 1.19    | Healthy               |
        | 0x17      | Vcc +0.75V SUS   | 0.75    | Healthy               |
        | 0x18      | Vcc +3.3V        | 3.29    | Healthy               |
        | 0x19      | Vcc +2.5V        | 2.47    | Healthy               |
        | 0x1a      | Vcc +1.8V        | 1.78    | Healthy               |
        | 0x1b      | Vcc +1.2V        | 1.21    | Healthy               |
        | 0x1c      | Vcc +1.0V        | 1.01    | Healthy               |
        | 0x1d      | Vbat +3V         | 3.04    | Healthy               |
        | 0x3f      | Power Good Latch | 0x8001  | Healthy               |
        | 0x40      | FPGA RW Status   | 0x8002  | Healthy               |
        | 0x41      | FPGA Heartbeat   | 0x8002  | Healthy               |
        | 0x48      | ShMC Redun State | 0x8002  | Healthy               |
Hotswap Status: Active
Product name: MSH8900
Part number: T4301X_2-X
Serial number: 9017011576
Manufacturing date: Thu Nov 15 14:39:00 2018
Type: HubNode
Status: Active
Model: MSH8900
HPM versions:
	BMC: 3.18.093413FB
	FPGA: 2.6.00000000
Management Network:
        Management MAC: 00:a0:a5:d0:93:b9
        IP Source: dhcp
        IP: 10.28.24.63
        Subnet: 255.255.255.0
        Gateway: 10.28.24.3
        VLAN: FFD
Payload IPs :
	Network Interfaces:
		Id: 1, 
		Backplane: Management, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:d0:93:9a
		IP Source: static

================================

================================
Name: HubNode 2
Health: Healthy
Health Details: 
        | Sensor ID | Sensor Name      | Value   | Health                |
         ---------------------------------------------------------------- 
        | 0x0b      | Temp On-Board    | 32.00   | Healthy               |
        | 0x0c      | Temp Eth Switch  | 34.00   | Healthy               |
        | 0x0d      | Temp Quad Phy    | 40.00   | Healthy               |
        | 0x0e      | Temp Inlet       | 25.00   | Healthy               |
        | 0x0f      | Temp Phy 10G     | 54.00   | Healthy               |
        | 0x10      | Vcc +12V In      | 12.18   | Healthy               |
        | 0x11      | Vcc +5V SUS      | 5.08    | Healthy               |
        | 0x12      | Vcc +3.3V SUS    | 3.29    | Healthy               |
        | 0x13      | Vcc +1.8V SUS    | 1.78    | Healthy               |
        | 0x14      | Vcc +1.5V SUS    | 1.50    | Healthy               |
        | 0x15      | Vcc +1.25V SUS   | 1.24    | Healthy               |
        | 0x16      | Vcc +1.2V SUS    | 1.19    | Healthy               |
        | 0x17      | Vcc +0.75V SUS   | 0.75    | Healthy               |
        | 0x18      | Vcc +3.3V        | 3.29    | Healthy               |
        | 0x19      | Vcc +2.5V        | 2.48    | Healthy               |
        | 0x1a      | Vcc +1.8V        | 1.78    | Healthy               |
        | 0x1b      | Vcc +1.2V        | 1.21    | Healthy               |
        | 0x1c      | Vcc +1.0V        | 1.01    | Healthy               |
        | 0x1d      | Vbat +3V         | 3.06    | Healthy               |
        | 0x3f      | Power Good Latch | 0x8001  | Healthy               |
        | 0x40      | FPGA RW Status   | 0x8002  | Healthy               |
        | 0x41      | FPGA Heartbeat   | 0x8002  | Healthy               |
        | 0x48      | ShMC Redun State | 0x8008  | Healthy               |
Hotswap Status: Active
Product name: MSH8900
Part number: T4301X_2-X
Serial number: 9017011545
Manufacturing date: Thu Nov 15 14:02:00 2018
Type: HubNode
Status: Standby
Model: MSH8900
HPM versions:
	BMC: 3.18.093413FB
	FPGA: 2.6.00000000
Management Network:
        Management MAC: 00:a0:a5:d0:a1:b3
        IP Source: dhcp
        IP: 10.28.24.138
        Subnet: 255.255.255.0
        Gateway: 10.28.24.3
        VLAN: FFD
Payload IPs :
	Network Interfaces:
		Id: 1, 
		Backplane: Management, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:d0:a1:94
		IP Source: static

================================

*******************************
Nodes
*******************************

================================
SLOT #1
================================
Name: Node 1
Health: Healthy
Health Details: 
        | Sensor ID | Sensor Name      | Value   | Health                |
         ---------------------------------------------------------------- 
        | 0x0e      | Vcc +12V SUS     | 12.12   | Healthy               |
        | 0x0f      | Vcc +5V SUS      | 5.01    | Healthy               |
        | 0x10      | Vcc +2.5V SUS    | 2.49    | Healthy               |
        | 0x11      | Vcc +1.8V SUS    | 1.81    | Healthy               |
        | 0x12      | Vcc +1.5V SUS    | 1.49    | Healthy               |
        | 0x13      | Vcc +1.25V SUS   | 1.25    | Healthy               |
        | 0x14      | Vcc +0.75V SUS   | 0.75    | Healthy               |
        | 0x04      | Temp Inlet       | 25.00   | Healthy               |
        | 0x05      | Temp Outlet      | 27.00   | Healthy               |
        | 0x06      | Temp Vcore       | 25.00   | Healthy               |
        | 0x07      | Temp BMC         | 34.00   | Healthy               |
        | 0x08      | Temp CPU 1       | 0.00    | Healthy               |
        | 0x09      | Temp CPU 2       | 0.00    | Healthy               |
Hotswap Status: Active
Product name: 4009
Part number: 1062-0224
Serial number: 9017014861
Manufacturing date: Mon Nov 26 15:44:00 2018
Type: Node
Model: MSP805x
HPM versions:
	BMC: 1.7.09341440
	FPGA: 1.2.00000000
	BIOS: 1.5.0926BD66
Management Network:
        Management MAC: 00:a0:a5:d1:3b:28
        IP Source: dhcp
        IP: 10.28.24.118
        Subnet: 255.255.255.0
        Gateway: 10.28.24.3
        VLAN: FFD
Payload IPs :
	Network Interfaces:
		Id: 1, 
		Backplane: Base2, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:d1:3b:22
		IP Source: static


		Id: 2, 
		Backplane: Fabric1p1, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:d1:3b:23
		IP Source: static


		Id: 3, 
		Backplane: Fabric2p2, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:d1:3b:24
		IP Source: static


	Network Interfaces:
		Id: 1, 
		Backplane: Base1, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:d1:3b:25
		IP Source: static


		Id: 2, 
		Backplane: Fabric1p2, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:d1:3b:26
		IP Source: static


		Id: 3, 
		Backplane: Fabric2p1, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:d1:3b:27
		IP Source: static

================================

================================
SLOT #2
================================
Name: Node 2
Health: Healthy
Health Details: 
        | Sensor ID | Sensor Name      | Value   | Health                |
         ---------------------------------------------------------------- 
        | 0x0e      | Vcc +12V SUS     | 12.12   | Healthy               |
        | 0x0f      | Vcc +5V SUS      | 4.93    | Healthy               |
        | 0x10      | Vcc +2.5V SUS    | 2.50    | Healthy               |
        | 0x11      | Vcc +1.8V SUS    | 1.81    | Healthy               |
        | 0x12      | Vcc +1.5V SUS    | 1.49    | Healthy               |
        | 0x13      | Vcc +1.25V SUS   | 1.26    | Healthy               |
        | 0x14      | Vcc +0.75V SUS   | 0.75    | Healthy               |
        | 0x04      | Temp Inlet       | 24.00   | Healthy               |
        | 0x05      | Temp Outlet      | 26.00   | Healthy               |
        | 0x06      | Temp Vcore       | 25.00   | Healthy               |
        | 0x07      | Temp BMC         | 33.00   | Healthy               |
        | 0x08      | Temp CPU 1       | 0.00    | Healthy               |
        | 0x09      | Temp CPU 2       | 0.00    | Healthy               |
Hotswap Status: Active
Product name: 4009
Part number: 1062-0224
Serial number: 9017015016
Manufacturing date: Mon Nov 26 15:44:00 2018
Type: Node
Model: MSP805x
HPM versions:
	BMC: 1.7.09341440
	FPGA: 1.2.00000000
	BIOS: 1.5.0926BD66
Management Network:
        Management MAC: 00:a0:a5:d2:0c:60
        IP Source: dhcp
        IP: 10.28.24.137
        Subnet: 255.255.255.0
        Gateway: 10.28.24.3
        VLAN: FFD
Payload IPs :
	Network Interfaces:
		Id: 1, 
		Backplane: Base2, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:d2:0c:5a
		IP Source: static


		Id: 2, 
		Backplane: Fabric1p1, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:d2:0c:5b
		IP Source: static


		Id: 3, 
		Backplane: Fabric2p2, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:d2:0c:5c
		IP Source: static


	Network Interfaces:
		Id: 1, 
		Backplane: Base1, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:d2:0c:5d
		IP Source: static


		Id: 2, 
		Backplane: Fabric1p2, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:d2:0c:5e
		IP Source: static


		Id: 3, 
		Backplane: Fabric2p1, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:d2:0c:5f
		IP Source: static

================================

================================
SLOT #3
================================
Name: Node 3
Health: Healthy
Health Details: 
        | Sensor ID | Sensor Name      | Value   | Health                |
         ---------------------------------------------------------------- 
        | 0x0e      | Vcc +12V SUS     | 12.06   | Healthy               |
        | 0x0f      | Vcc +5V SUS      | 5.01    | Healthy               |
        | 0x10      | Vcc +2.5V SUS    | 2.50    | Healthy               |
        | 0x11      | Vcc +1.8V SUS    | 1.80    | Healthy               |
        | 0x12      | Vcc +1.5V SUS    | 1.49    | Healthy               |
        | 0x13      | Vcc +1.25V SUS   | 1.26    | Healthy               |
        | 0x14      | Vcc +0.75V SUS   | 0.74    | Healthy               |
        | 0x04      | Temp Inlet       | 23.00   | Healthy               |
        | 0x05      | Temp Outlet      | 25.00   | Healthy               |
        | 0x06      | Temp Vcore       | 24.00   | Healthy               |
        | 0x07      | Temp BMC         | 32.00   | Healthy               |
        | 0x08      | Temp CPU 1       | 0.00    | Healthy               |
        | 0x09      | Temp CPU 2       | 0.00    | Healthy               |
Hotswap Status: Active
Product name: 4009
Part number: 1062-0224
Serial number: 9017014850
Manufacturing date: Mon Nov 26 15:43:00 2018
Type: Node
Model: MSP805x
HPM versions:
	BMC: 1.7.09341440
	FPGA: 1.2.00000000
	BIOS: 1.5.0926BD66
Management Network:
        Management MAC: 00:a0:a5:d1:3b:20
        IP Source: dhcp
        IP: 10.28.24.59
        Subnet: 255.255.255.0
        Gateway: 10.28.24.3
        VLAN: FFD
Payload IPs :
	Network Interfaces:
		Id: 1, 
		Backplane: Base2, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:d1:3b:1a
		IP Source: static


		Id: 2, 
		Backplane: Fabric1p1, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:d1:3b:1b
		IP Source: static


		Id: 3, 
		Backplane: Fabric2p2, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:d1:3b:1c
		IP Source: static


	Network Interfaces:
		Id: 1, 
		Backplane: Base1, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:d1:3b:1d
		IP Source: static


		Id: 2, 
		Backplane: Fabric1p2, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:d1:3b:1e
		IP Source: static


		Id: 3, 
		Backplane: Fabric2p1, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:d1:3b:1f
		IP Source: static

================================

================================
SLOT #4
================================
Name: Node 4
Health: Healthy
Health Details: 
        | Sensor ID | Sensor Name      | Value   | Health                |
         ---------------------------------------------------------------- 
        | 0x0e      | Vcc +12V SUS     | 12.12   | Healthy               |
        | 0x0f      | Vcc +5V SUS      | 4.98    | Healthy               |
        | 0x10      | Vcc +2.5V SUS    | 2.49    | Healthy               |
        | 0x11      | Vcc +1.8V SUS    | 1.80    | Healthy               |
        | 0x12      | Vcc +1.5V SUS    | 1.50    | Healthy               |
        | 0x13      | Vcc +1.25V SUS   | 1.24    | Healthy               |
        | 0x14      | Vcc +0.75V SUS   | 0.75    | Healthy               |
        | 0x04      | Temp Inlet       | 25.00   | Healthy               |
        | 0x05      | Temp Outlet      | 26.00   | Healthy               |
        | 0x07      | Temp BMC         | 34.00   | Healthy               |
        | 0x08      | Temp CPU 1       | 0.00    | Healthy               |
        | 0x09      | Temp CPU 2       | 0.00    | Healthy               |
Hotswap Status: Active
Product name: 4009
Part number: 1062-0224
Serial number: 9017048128
Manufacturing date: Tue Apr 21 14:55:00 2020
Type: Node
Model: MSP805x
HPM versions:
	BMC: 1.6.09289DBB
	FPGA: 1.0.00000000
	BIOS: 1.5.0926BD66
Management Network:
        Management MAC: 00:a0:a5:db:ea:22
        IP Source: dhcp
        IP: 10.28.24.60
        Subnet: 255.255.255.0
        Gateway: 10.28.24.3
        VLAN: FFD
Payload IPs :
	Network Interfaces:
		Id: 1, 
		Backplane: Base2, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:db:ea:1c
		IP Source: static


		Id: 2, 
		Backplane: Fabric1p1, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:db:ea:1d
		IP Source: static


		Id: 3, 
		Backplane: Fabric2p2, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:db:ea:1e
		IP Source: static


	Network Interfaces:
		Id: 1, 
		Backplane: Base1, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:db:ea:1f
		IP Source: static


		Id: 2, 
		Backplane: Fabric1p2, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:db:ea:20
		IP Source: static


		Id: 3, 
		Backplane: Fabric2p1, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:db:ea:21
		IP Source: static

================================

================================
SLOT #5
================================
Name: Node 5
Health: Healthy
Health Details: 
        | Sensor ID | Sensor Name      | Value   | Health                |
         ---------------------------------------------------------------- 
        | 0x0e      | Vcc +12V SUS     | 12.12   | Healthy               |
        | 0x0f      | Vcc +5V SUS      | 5.01    | Healthy               |
        | 0x10      | Vcc +2.5V SUS    | 2.49    | Healthy               |
        | 0x11      | Vcc +1.8V SUS    | 1.80    | Healthy               |
        | 0x12      | Vcc +1.5V SUS    | 1.50    | Healthy               |
        | 0x13      | Vcc +1.25V SUS   | 1.25    | Healthy               |
        | 0x14      | Vcc +0.75V SUS   | 0.74    | Healthy               |
        | 0x04      | Temp Inlet       | 24.00   | Healthy               |
        | 0x05      | Temp Outlet      | 26.00   | Healthy               |
        | 0x06      | Temp Vcore       | 24.00   | Healthy               |
        | 0x07      | Temp BMC         | 32.00   | Healthy               |
        | 0x08      | Temp CPU 1       | 0.00    | Healthy               |
        | 0x09      | Temp CPU 2       | 0.00    | Healthy               |
Hotswap Status: Active
Product name: 4009
Part number: 1062-0224
Serial number: 9017014839
Manufacturing date: Mon Nov 26 16:00:00 2018
Type: Node
Model: MSP805x
HPM versions:
	BMC: 1.7.09341440
	FPGA: 1.2.00000000
	BIOS: 1.5.0926BD66
Management Network:
        Management MAC: 00:a0:a5:d1:3e:d0
        IP Source: dhcp
        IP: 10.28.24.58
        Subnet: 255.255.255.0
        Gateway: 10.28.24.3
        VLAN: FFD
Payload IPs :
	Network Interfaces:
		Id: 1, 
		Backplane: Base2, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:d1:3e:ca
		IP Source: static


		Id: 2, 
		Backplane: Fabric1p1, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:d1:3e:cb
		IP Source: static


		Id: 3, 
		Backplane: Fabric2p2, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:d1:3e:cc
		IP Source: static


	Network Interfaces:
		Id: 1, 
		Backplane: Base1, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:d1:3e:cd
		IP Source: static


		Id: 2, 
		Backplane: Fabric1p2, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:d1:3e:ce
		IP Source: static


		Id: 3, 
		Backplane: Fabric2p1, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:d1:3e:cf
		IP Source: static

================================

================================
SLOT #6
================================
Name: Node 6
Health: Healthy
Health Details: 
        | Sensor ID | Sensor Name      | Value   | Health                |
         ---------------------------------------------------------------- 
        | 0x0e      | Vcc +12V SUS     | 12.12   | Healthy               |
        | 0x0f      | Vcc +5V SUS      | 4.96    | Healthy               |
        | 0x10      | Vcc +2.5V SUS    | 2.50    | Healthy               |
        | 0x11      | Vcc +1.8V SUS    | 1.80    | Healthy               |
        | 0x12      | Vcc +1.5V SUS    | 1.50    | Healthy               |
        | 0x13      | Vcc +1.25V SUS   | 1.25    | Healthy               |
        | 0x14      | Vcc +0.75V SUS   | 0.75    | Healthy               |
        | 0x04      | Temp Inlet       | 23.00   | Healthy               |
        | 0x05      | Temp Outlet      | 25.00   | Healthy               |
        | 0x06      | Temp Vcore       | 24.00   | Healthy               |
        | 0x07      | Temp BMC         | 32.00   | Healthy               |
        | 0x08      | Temp CPU 1       | 0.00    | Healthy               |
        | 0x09      | Temp CPU 2       | 0.00    | Healthy               |
Hotswap Status: Active
Product name: 4009
Part number: 1062-0224
Serial number: 9017014952
Manufacturing date: Mon Nov 26 16:01:00 2018
Type: Node
Model: MSP805x
HPM versions:
	BMC: 1.7.09341440
	FPGA: 1.2.00000000
	BIOS: 1.5.0926BD66
Management Network:
        Management MAC: 00:a0:a5:d1:40:38
        IP Source: dhcp
        IP: 10.28.24.136
        Subnet: 255.255.255.0
        Gateway: 10.28.24.3
        VLAN: FFD
Payload IPs :
	Network Interfaces:
		Id: 1, 
		Backplane: Base2, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:d1:40:32
		IP Source: static


		Id: 2, 
		Backplane: Fabric1p1, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:d1:40:33
		IP Source: static


		Id: 3, 
		Backplane: Fabric2p2, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:d1:40:34
		IP Source: static


	Network Interfaces:
		Id: 1, 
		Backplane: Base1, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:d1:40:35
		IP Source: static


		Id: 2, 
		Backplane: Fabric1p2, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:d1:40:36
		IP Source: static


		Id: 3, 
		Backplane: Fabric2p1, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:d1:40:37
		IP Source: static

================================

================================
SLOT #7
================================
Name: Node 7
Health: Healthy
Health Details: 
        | Sensor ID | Sensor Name      | Value   | Health                |
         ---------------------------------------------------------------- 
        | 0x0e      | Vcc +12V SUS     | 12.12   | Healthy               |
        | 0x0f      | Vcc +5V SUS      | 5.03    | Healthy               |
        | 0x10      | Vcc +2.5V SUS    | 2.48    | Healthy               |
        | 0x11      | Vcc +1.8V SUS    | 1.80    | Healthy               |
        | 0x12      | Vcc +1.5V SUS    | 1.50    | Healthy               |
        | 0x13      | Vcc +1.25V SUS   | 1.24    | Healthy               |
        | 0x14      | Vcc +0.75V SUS   | 0.74    | Healthy               |
        | 0x04      | Temp Inlet       | 24.00   | Healthy               |
        | 0x05      | Temp Outlet      | 27.00   | Healthy               |
        | 0x06      | Temp Vcore       | 25.00   | Healthy               |
        | 0x07      | Temp BMC         | 34.00   | Healthy               |
        | 0x08      | Temp CPU 1       | 0.00    | Healthy               |
        | 0x09      | Temp CPU 2       | 0.00    | Healthy               |
Hotswap Status: Active
Product name: 4009
Part number: 1062-0224
Serial number: 9017014886
Manufacturing date: Mon Nov 26 16:01:00 2018
Type: Node
Model: MSP805x
HPM versions:
	BMC: 1.7.09341440
	FPGA: 1.2.00000000
	BIOS: 1.5.0926BD66
Management Network:
        Management MAC: 00:a0:a5:d1:3a:28
        IP Source: dhcp
        IP: 10.28.24.56
        Subnet: 255.255.255.0
        Gateway: 10.28.24.3
        VLAN: FFD
Payload IPs :
	Network Interfaces:
		Id: 1, 
		Backplane: Base2, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:d1:3a:22
		IP Source: static


		Id: 2, 
		Backplane: Fabric1p1, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:d1:3a:23
		IP Source: static


		Id: 3, 
		Backplane: Fabric2p2, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:d1:3a:24
		IP Source: static


	Network Interfaces:
		Id: 1, 
		Backplane: Base1, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:d1:3a:25
		IP Source: static


		Id: 2, 
		Backplane: Fabric1p2, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:d1:3a:26
		IP Source: static


		Id: 3, 
		Backplane: Fabric2p1, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:d1:3a:27
		IP Source: static

================================

================================
SLOT #8
================================
Name: Node 8
Health: Healthy
Health Details: 
        | Sensor ID | Sensor Name      | Value   | Health                |
         ---------------------------------------------------------------- 
        | 0x0e      | Vcc +12V SUS     | 12.12   | Healthy               |
        | 0x0f      | Vcc +5V SUS      | 4.98    | Healthy               |
        | 0x10      | Vcc +2.5V SUS    | 2.50    | Healthy               |
        | 0x11      | Vcc +1.8V SUS    | 1.81    | Healthy               |
        | 0x12      | Vcc +1.5V SUS    | 1.50    | Healthy               |
        | 0x13      | Vcc +1.25V SUS   | 1.24    | Healthy               |
        | 0x14      | Vcc +0.75V SUS   | 0.76    | Healthy               |
        | 0x04      | Temp Inlet       | 23.00   | Healthy               |
        | 0x05      | Temp Outlet      | 26.00   | Healthy               |
        | 0x06      | Temp Vcore       | 24.00   | Healthy               |
        | 0x07      | Temp BMC         | 32.00   | Healthy               |
        | 0x08      | Temp CPU 1       | 0.00    | Healthy               |
        | 0x09      | Temp CPU 2       | 0.00    | Healthy               |
Hotswap Status: Active
Product name: 4009
Part number: 1062-0224
Serial number: 9017014805
Manufacturing date: Mon Nov 26 16:05:00 2018
Type: Node
Model: MSP805x
HPM versions:
	BMC: 1.7.09341440
	FPGA: 1.2.00000000
	BIOS: 1.5.0926BD66
Management Network:
        Management MAC: 00:a0:a5:d1:39:40
        IP Source: dhcp
        IP: 10.28.24.57
        Subnet: 255.255.255.0
        Gateway: 10.28.24.3
        VLAN: FFD
Payload IPs :
	Network Interfaces:
		Id: 1, 
		Backplane: Base2, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:d1:39:3a
		IP Source: static


		Id: 2, 
		Backplane: Fabric1p1, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:d1:39:3b
		IP Source: static


		Id: 3, 
		Backplane: Fabric2p2, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:d1:39:3c
		IP Source: static


	Network Interfaces:
		Id: 1, 
		Backplane: Base1, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:d1:39:3d
		IP Source: static


		Id: 2, 
		Backplane: Fabric1p2, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:d1:39:3e
		IP Source: static


		Id: 3, 
		Backplane: Fabric2p1, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:d1:39:3f
		IP Source: static

================================

================================
SLOT #9
================================
Name: Node 9
Health: Healthy
Health Details: 
        | Sensor ID | Sensor Name      | Value   | Health                |
         ---------------------------------------------------------------- 
        | 0x0e      | Vcc +12V SUS     | 12.12   | Healthy               |
        | 0x0f      | Vcc +5V SUS      | 4.98    | Healthy               |
        | 0x10      | Vcc +2.5V SUS    | 2.52    | Healthy               |
        | 0x11      | Vcc +1.8V SUS    | 1.81    | Healthy               |
        | 0x12      | Vcc +1.5V SUS    | 1.50    | Healthy               |
        | 0x13      | Vcc +1.25V SUS   | 1.24    | Healthy               |
        | 0x14      | Vcc +0.75V SUS   | 0.75    | Healthy               |
        | 0x04      | Temp Inlet       | 23.00   | Healthy               |
        | 0x05      | Temp Outlet      | 25.00   | Healthy               |
        | 0x06      | Temp Vcore       | 23.00   | Healthy               |
        | 0x07      | Temp BMC         | 31.00   | Healthy               |
        | 0x08      | Temp CPU 1       | 0.00    | Healthy               |
        | 0x09      | Temp CPU 2       | 0.00    | Healthy               |
Hotswap Status: Active
Product name: 4009
Part number: 1062-0224
Serial number: 9017010752
Manufacturing date: Fri Nov 16 16:36:00 2018
Type: Node
Model: MSP805x
HPM versions:
	BMC: 1.7.09341440
	FPGA: 1.2.00000000
	BIOS: 1.5.0926BD66
Management Network:
        Management MAC: 00:a0:a5:cf:cd:fa
        IP Source: dhcp
        IP: 10.28.24.62
        Subnet: 255.255.255.0
        Gateway: 10.28.24.3
        VLAN: FFD
Payload IPs :
	Network Interfaces:
		Id: 1, 
		Backplane: Base2, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:cf:cd:f4
		IP Source: static


		Id: 2, 
		Backplane: Fabric1p1, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:cf:cd:f5
		IP Source: static


		Id: 3, 
		Backplane: Fabric2p2, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:cf:cd:f6
		IP Source: static


	Network Interfaces:
		Id: 1, 
		Backplane: Base1, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:cf:cd:f7
		IP Source: static


		Id: 2, 
		Backplane: Fabric1p2, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:cf:cd:f8
		IP Source: static


		Id: 3, 
		Backplane: Fabric2p1, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:cf:cd:f9
		IP Source: static

================================

*******************************
Original JSON string
*******************************
{ "name": "Platform #1", "number": "1", "chassis": "ms2900", "health": "Green", "fans":[ {"number": "1", "name": "Fan 1", "type": "fan", "health": "Green", "rpm": "8162","alarm": {"alarmlevel": "None"}, "LedIdentify": {"status": "off"}, "hotswapStatus":{"state": "M4", "text": "Active"}}, {"number": "2", "name": "Fan 2", "type": "fan", "health": "Green", "rpm": "8008","alarm": {"alarmlevel": "None"}, "LedIdentify": {"status": "off"}, "hotswapStatus":{"state": "M4", "text": "Active"}}, {"number": "3", "name": "Fan 3", "type": "fan", "health": "Green", "rpm": "8239","alarm": {"alarmlevel": "None"}, "LedIdentify": {"status": "off"}, "hotswapStatus":{"state": "M4", "text": "Active"}}, {"number": "4", "name": "Fan 4", "type": "fan", "health": "Green", "rpm": "8239","alarm": {"alarmlevel": "None"}, "LedIdentify": {"status": "off"}, "hotswapStatus":{"state": "M4", "text": "Active"}}, {"number": "5", "name": "Fan 5", "type": "fan", "health": "Green", "rpm": "8085","alarm": {"alarmlevel": "None"}, "LedIdentify": {"status": "off"}, "hotswapStatus":{"state": "M4", "text": "Active"}} ], "type": "platform", "components": [{"number": "10", "name": "HubNode 1", "health": "Green", "fruInfo": {"mfgDate": "Thu Nov 15 14:39:00 2018", "boardMfg": "Kontron", "boardProductName": "MSH8900", "boardProductPart": "T4301X_2-X", "boardSerialNumber": "9017011576"},"hotswapStatus":{"state": "M4", "text": "Active"},"type":"hubnode", "HubNodeFeatures":{"SwitchSpeedSupport": "1", "PortModeSupport": "0"}, "versions" : [{ "name" : "BMC", "major" : "3", "minor" : "18", "revision" : "093413FB"},{ "name" : "FPGA", "major" : "2", "minor" : "06", "revision" : "00000000"}],"model": "MSH8900", "isUpdating" : "0", "managementIP": "10.28.24.63", "managementMAC": "00:a0:a5:d0:93:b9", "alarm": {"alarmlevel": "None", "sensors":[]}, "LedIdentify": {"status": "off"}, "components": [{ "description": "Switch 1", "number": "1", "hotswapStatus":{"state": "M4", "text": "Active"}, "networkInterfaces": [{ "id": "1", "backplane": "Management", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:d0:93:9a"}]}], "status": "Active"}, {"number": "11", "name": "HubNode 2", "health": "Green", "fruInfo": {"mfgDate": "Thu Nov 15 14:02:00 2018", "boardMfg": "Kontron", "boardProductName": "MSH8900", "boardProductPart": "T4301X_2-X", "boardSerialNumber": "9017011545"},"hotswapStatus":{"state": "M4", "text": "Active"},"type":"hubnode", "HubNodeFeatures":{"SwitchSpeedSupport": "1", "PortModeSupport": "0"}, "versions" : [{ "name" : "BMC", "major" : "3", "minor" : "18", "revision" : "093413FB"},{ "name" : "FPGA", "major" : "2", "minor" : "06", "revision" : "00000000"}],"model": "MSH8900", "isUpdating" : "0", "managementIP": "10.28.24.138", "managementMAC": "00:a0:a5:d0:a1:b3", "alarm": {"alarmlevel": "None", "sensors":[]}, "LedIdentify": {"status": "off"}, "components": [{ "description": "Switch 2", "number": "1", "hotswapStatus":{"state": "M4", "text": "Active"}, "networkInterfaces": [{ "id": "1", "backplane": "Management", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:d0:a1:94"}]}], "status": "Standby"}, {"number": "1", "name": "Node 1", "health": "Green", "fruInfo": {"mfgDate": "Mon Nov 26 15:44:00 2018", "boardMfg": "Kontron", "boardProductName": "4009", "boardProductPart": "1062-0224", "boardSerialNumber": "9017014861"},"hotswapStatus":{"state": "M4", "text": "Active"},"type":"node", "versions" : [{ "name" : "BMC", "major" : "1", "minor" : "07", "revision" : "09341440"},{ "name" : "FPGA", "major" : "1", "minor" : "02", "revision" : "00000000"},{ "name" : "BIOS", "major" : "1", "minor" : "05", "revision" : "0926BD66"}],"model": "MSP805x", "isUpdating" : "0", "managementIP": "10.28.24.118", "managementMAC": "00:a0:a5:d1:3b:28", "alarm": {"alarmlevel": "None", "sensors":[]}, "LedIdentify": {"status": "off"}, "components": [{ "description": "Payload1       ", "number": "1", "hotswapStatus":{"state": "M1", "text": "Inactive"}, "networkInterfaces": [{ "id": "1", "backplane": "Base2", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:d1:3b:22"}, { "id": "2", "backplane": "Fabric1p1", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:d1:3b:23"}, { "id": "3", "backplane": "Fabric2p2", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:d1:3b:24"}]}, { "description": "Payload2       ", "number": "2", "hotswapStatus":{"state": "M1", "text": "Inactive"}, "networkInterfaces": [{ "id": "1", "backplane": "Base1", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:d1:3b:25"}, { "id": "2", "backplane": "Fabric1p2", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:d1:3b:26"}, { "id": "3", "backplane": "Fabric2p1", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:d1:3b:27"}]}] }, {"number": "2", "name": "Node 2", "health": "Green", "fruInfo": {"mfgDate": "Mon Nov 26 15:44:00 2018", "boardMfg": "Kontron", "boardProductName": "4009", "boardProductPart": "1062-0224", "boardSerialNumber": "9017015016"},"hotswapStatus":{"state": "M4", "text": "Active"},"type":"node", "versions" : [{ "name" : "BMC", "major" : "1", "minor" : "07", "revision" : "09341440"},{ "name" : "FPGA", "major" : "1", "minor" : "02", "revision" : "00000000"},{ "name" : "BIOS", "major" : "1", "minor" : "05", "revision" : "0926BD66"}],"model": "MSP805x", "isUpdating" : "0", "managementIP": "10.28.24.137", "managementMAC": "00:a0:a5:d2:0c:60", "alarm": {"alarmlevel": "None", "sensors":[]}, "LedIdentify": {"status": "off"}, "components": [{ "description": "Payload1       ", "number": "1", "hotswapStatus":{"state": "M1", "text": "Inactive"}, "networkInterfaces": [{ "id": "1", "backplane": "Base2", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:d2:0c:5a"}, { "id": "2", "backplane": "Fabric1p1", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:d2:0c:5b"}, { "id": "3", "backplane": "Fabric2p2", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:d2:0c:5c"}]}, { "description": "Payload2       ", "number": "2", "hotswapStatus":{"state": "M1", "text": "Inactive"}, "networkInterfaces": [{ "id": "1", "backplane": "Base1", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:d2:0c:5d"}, { "id": "2", "backplane": "Fabric1p2", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:d2:0c:5e"}, { "id": "3", "backplane": "Fabric2p1", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:d2:0c:5f"}]}] }, {"number": "3", "name": "Node 3", "health": "Green", "fruInfo": {"mfgDate": "Mon Nov 26 15:43:00 2018", "boardMfg": "Kontron", "boardProductName": "4009", "boardProductPart": "1062-0224", "boardSerialNumber": "9017014850"},"hotswapStatus":{"state": "M4", "text": "Active"},"type":"node", "versions" : [{ "name" : "BMC", "major" : "1", "minor" : "07", "revision" : "09341440"},{ "name" : "FPGA", "major" : "1", "minor" : "02", "revision" : "00000000"},{ "name" : "BIOS", "major" : "1", "minor" : "05", "revision" : "0926BD66"}],"model": "MSP805x", "isUpdating" : "0", "managementIP": "10.28.24.59", "managementMAC": "00:a0:a5:d1:3b:20", "alarm": {"alarmlevel": "None", "sensors":[]}, "LedIdentify": {"status": "off"}, "components": [{ "description": "Payload1       ", "number": "1", "hotswapStatus":{"state": "M1", "text": "Inactive"}, "networkInterfaces": [{ "id": "1", "backplane": "Base2", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:d1:3b:1a"}, { "id": "2", "backplane": "Fabric1p1", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:d1:3b:1b"}, { "id": "3", "backplane": "Fabric2p2", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:d1:3b:1c"}]}, { "description": "Payload2       ", "number": "2", "hotswapStatus":{"state": "M1", "text": "Inactive"}, "networkInterfaces": [{ "id": "1", "backplane": "Base1", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:d1:3b:1d"}, { "id": "2", "backplane": "Fabric1p2", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:d1:3b:1e"}, { "id": "3", "backplane": "Fabric2p1", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:d1:3b:1f"}]}] }, {"number": "4", "name": "Node 4", "health": "Green", "fruInfo": {"mfgDate": "Tue Apr 21 14:55:00 2020", "boardMfg": "Kontron", "boardProductName": "4009", "boardProductPart": "1062-0224", "boardSerialNumber": "9017048128"},"hotswapStatus":{"state": "M4", "text": "Active"},"type":"node", "versions" : [{ "name" : "BMC", "major" : "1", "minor" : "06", "revision" : "09289DBB"},{ "name" : "FPGA", "major" : "1", "minor" : "00", "revision" : "00000000"},{ "name" : "BIOS", "major" : "1", "minor" : "05", "revision" : "0926BD66"}],"model": "MSP805x", "isUpdating" : "0", "managementIP": "10.28.24.60", "managementMAC": "00:a0:a5:db:ea:22", "alarm": {"alarmlevel": "None", "sensors":[]}, "LedIdentify": {"status": "off"}, "components": [{ "description": "Payload1       ", "number": "1", "hotswapStatus":{"state": "M1", "text": "Inactive"}, "networkInterfaces": [{ "id": "1", "backplane": "Base2", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:db:ea:1c"}, { "id": "2", "backplane": "Fabric1p1", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:db:ea:1d"}, { "id": "3", "backplane": "Fabric2p2", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:db:ea:1e"}]}, { "description": "Payload2       ", "number": "2", "hotswapStatus":{"state": "M1", "text": "Inactive"}, "networkInterfaces": [{ "id": "1", "backplane": "Base1", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:db:ea:1f"}, { "id": "2", "backplane": "Fabric1p2", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:db:ea:20"}, { "id": "3", "backplane": "Fabric2p1", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:db:ea:21"}]}] }, {"number": "5", "name": "Node 5", "health": "Green", "fruInfo": {"mfgDate": "Mon Nov 26 16:00:00 2018", "boardMfg": "Kontron", "boardProductName": "4009", "boardProductPart": "1062-0224", "boardSerialNumber": "9017014839"},"hotswapStatus":{"state": "M4", "text": "Active"},"type":"node", "versions" : [{ "name" : "BMC", "major" : "1", "minor" : "07", "revision" : "09341440"},{ "name" : "FPGA", "major" : "1", "minor" : "02", "revision" : "00000000"},{ "name" : "BIOS", "major" : "1", "minor" : "05", "revision" : "0926BD66"}],"model": "MSP805x", "isUpdating" : "0", "managementIP": "10.28.24.58", "managementMAC": "00:a0:a5:d1:3e:d0", "alarm": {"alarmlevel": "None", "sensors":[]}, "LedIdentify": {"status": "off"}, "components": [{ "description": "Payload1       ", "number": "1", "hotswapStatus":{"state": "M1", "text": "Inactive"}, "networkInterfaces": [{ "id": "1", "backplane": "Base2", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:d1:3e:ca"}, { "id": "2", "backplane": "Fabric1p1", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:d1:3e:cb"}, { "id": "3", "backplane": "Fabric2p2", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:d1:3e:cc"}]}, { "description": "Payload2       ", "number": "2", "hotswapStatus":{"state": "M1", "text": "Inactive"}, "networkInterfaces": [{ "id": "1", "backplane": "Base1", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:d1:3e:cd"}, { "id": "2", "backplane": "Fabric1p2", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:d1:3e:ce"}, { "id": "3", "backplane": "Fabric2p1", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:d1:3e:cf"}]}] }, {"number": "6", "name": "Node 6", "health": "Green", "fruInfo": {"mfgDate": "Mon Nov 26 16:01:00 2018", "boardMfg": "Kontron", "boardProductName": "4009", "boardProductPart": "1062-0224", "boardSerialNumber": "9017014952"},"hotswapStatus":{"state": "M4", "text": "Active"},"type":"node", "versions" : [{ "name" : "BMC", "major" : "1", "minor" : "07", "revision" : "09341440"},{ "name" : "FPGA", "major" : "1", "minor" : "02", "revision" : "00000000"},{ "name" : "BIOS", "major" : "1", "minor" : "05", "revision" : "0926BD66"}],"model": "MSP805x", "isUpdating" : "0", "managementIP": "10.28.24.136", "managementMAC": "00:a0:a5:d1:40:38", "alarm": {"alarmlevel": "None", "sensors":[]}, "LedIdentify": {"status": "off"}, "components": [{ "description": "Payload1       ", "number": "1", "hotswapStatus":{"state": "M1", "text": "Inactive"}, "networkInterfaces": [{ "id": "1", "backplane": "Base2", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:d1:40:32"}, { "id": "2", "backplane": "Fabric1p1", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:d1:40:33"}, { "id": "3", "backplane": "Fabric2p2", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:d1:40:34"}]}, { "description": "Payload2       ", "number": "2", "hotswapStatus":{"state": "M1", "text": "Inactive"}, "networkInterfaces": [{ "id": "1", "backplane": "Base1", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:d1:40:35"}, { "id": "2", "backplane": "Fabric1p2", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:d1:40:36"}, { "id": "3", "backplane": "Fabric2p1", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:d1:40:37"}]}] }, {"number": "7", "name": "Node 7", "health": "Green", "fruInfo": {"mfgDate": "Mon Nov 26 16:01:00 2018", "boardMfg": "Kontron", "boardProductName": "4009", "boardProductPart": "1062-0224", "boardSerialNumber": "9017014886"},"hotswapStatus":{"state": "M4", "text": "Active"},"type":"node", "versions" : [{ "name" : "BMC", "major" : "1", "minor" : "07", "revision" : "09341440"},{ "name" : "FPGA", "major" : "1", "minor" : "02", "revision" : "00000000"},{ "name" : "BIOS", "major" : "1", "minor" : "05", "revision" : "0926BD66"}],"model": "MSP805x", "isUpdating" : "0", "managementIP": "10.28.24.56", "managementMAC": "00:a0:a5:d1:3a:28", "alarm": {"alarmlevel": "None", "sensors":[]}, "LedIdentify": {"status": "off"}, "components": [{ "description": "Payload1       ", "number": "1", "hotswapStatus":{"state": "M1", "text": "Inactive"}, "networkInterfaces": [{ "id": "1", "backplane": "Base2", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:d1:3a:22"}, { "id": "2", "backplane": "Fabric1p1", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:d1:3a:23"}, { "id": "3", "backplane": "Fabric2p2", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:d1:3a:24"}]}, { "description": "Payload2       ", "number": "2", "hotswapStatus":{"state": "M1", "text": "Inactive"}, "networkInterfaces": [{ "id": "1", "backplane": "Base1", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:d1:3a:25"}, { "id": "2", "backplane": "Fabric1p2", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:d1:3a:26"}, { "id": "3", "backplane": "Fabric2p1", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:d1:3a:27"}]}] }, {"number": "8", "name": "Node 8", "health": "Green", "fruInfo": {"mfgDate": "Mon Nov 26 16:05:00 2018", "boardMfg": "Kontron", "boardProductName": "4009", "boardProductPart": "1062-0224", "boardSerialNumber": "9017014805"},"hotswapStatus":{"state": "M4", "text": "Active"},"type":"node", "versions" : [{ "name" : "BMC", "major" : "1", "minor" : "07", "revision" : "09341440"},{ "name" : "FPGA", "major" : "1", "minor" : "02", "revision" : "00000000"},{ "name" : "BIOS", "major" : "1", "minor" : "05", "revision" : "0926BD66"}],"model": "MSP805x", "isUpdating" : "0", "managementIP": "10.28.24.57", "managementMAC": "00:a0:a5:d1:39:40", "alarm": {"alarmlevel": "None", "sensors":[]}, "LedIdentify": {"status": "off"}, "components": [{ "description": "Payload1       ", "number": "1", "hotswapStatus":{"state": "M1", "text": "Inactive"}, "networkInterfaces": [{ "id": "1", "backplane": "Base2", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:d1:39:3a"}, { "id": "2", "backplane": "Fabric1p1", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:d1:39:3b"}, { "id": "3", "backplane": "Fabric2p2", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:d1:39:3c"}]}, { "description": "Payload2       ", "number": "2", "hotswapStatus":{"state": "M1", "text": "Inactive"}, "networkInterfaces": [{ "id": "1", "backplane": "Base1", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:d1:39:3d"}, { "id": "2", "backplane": "Fabric1p2", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:d1:39:3e"}, { "id": "3", "backplane": "Fabric2p1", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:d1:39:3f"}]}] }, {"number": "9", "name": "Node 9", "health": "Green", "fruInfo": {"mfgDate": "Fri Nov 16 16:36:00 2018", "boardMfg": "Kontron", "boardProductName": "4009", "boardProductPart": "1062-0224", "boardSerialNumber": "9017010752"},"hotswapStatus":{"state": "M4", "text": "Active"},"type":"node", "versions" : [{ "name" : "BMC", "major" : "1", "minor" : "07", "revision" : "09341440"},{ "name" : "FPGA", "major" : "1", "minor" : "02", "revision" : "00000000"},{ "name" : "BIOS", "major" : "1", "minor" : "05", "revision" : "0926BD66"}],"model": "MSP805x", "isUpdating" : "0", "managementIP": "10.28.24.62", "managementMAC": "00:a0:a5:cf:cd:fa", "alarm": {"alarmlevel": "None", "sensors":[]}, "LedIdentify": {"status": "off"}, "components": [{ "description": "Payload1       ", "number": "1", "hotswapStatus":{"state": "M1", "text": "Inactive"}, "networkInterfaces": [{ "id": "1", "backplane": "Base2", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:cf:cd:f4"}, { "id": "2", "backplane": "Fabric1p1", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:cf:cd:f5"}, { "id": "3", "backplane": "Fabric2p2", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:cf:cd:f6"}]}, { "description": "Payload2       ", "number": "2", "hotswapStatus":{"state": "M1", "text": "Inactive"}, "networkInterfaces": [{ "id": "1", "backplane": "Base1", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:cf:cd:f7"}, { "id": "2", "backplane": "Fabric1p2", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:cf:cd:f8"}, { "id": "3", "backplane": "Fabric2p1", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:cf:cd:f9"}]}] }, { "name": "PSU", "components": [{"id": "PSU1", "number": "1", "name": "Power Supply 1", "health": "Green", "type": "psu", "hotswapStatus":{"state": "M4", "text": "Active"},"alarm": {"alarmlevel": "None"}, "tempInlet": "21.00", "tempOutlet": "26.00", "vIn": "206.00", "powerOut": "48", "powerScale": "1400","peakConsumption": "480", "averageConsumption": "282"},{"id": "PSU2", "number": "2", "name": "Power Supply 2", "health": "Green", "type": "psu", "hotswapStatus":{"state": "M4", "text": "Active"},"alarm": {"alarmlevel": "None"}, "tempInlet": "21.00", "tempOutlet": "26.00", "vIn": "206.00", "powerOut": "32", "powerScale": "1400","peakConsumption": "464", "averageConsumption": "266"}]}], "switchOID": {"oid": "1.3.6.1.4.1.6603"}, "alarm": {"alarmlevel": "None",  "components" : [ {"nodes" : [] } , {"psu" : [] }, {"fans" : [] }], "text": ""}, "LedIdentify": {"status": "off"}}