System informations
*******************************
Name: SYMKLOUD
chassis: ms2900
Health: Healthy
*******************************
Fans: 
*******************************
Fan 1: 
	Present :true
	Status :Healthy
	8008 RPM
Fan 2: 
	Present :true
	Status :Healthy
	8008 RPM
Fan 3: 
	Present :true
	Status :Healthy
	8162 RPM
Fan 4: 
	Present :true
	Status :Healthy
	8239 RPM
Fan 5: 
	Present :true
	Status :Healthy
	8239 RPM


*******************************
PSU: 
*******************************
Name: PSU 1
Health: Healthy
Health Details: No details available
Hotswap Status: Active
FRU: Informations are invalid

Name: PSU 2
Health: Healthy
Health Details: No details available
Hotswap Status: Active
FRU: Informations are invalid



*******************************
HubNodes
*******************************

================================
Name: HubNode 1
Health: Healthy
Health Details: 
        | Sensor ID | Sensor Name      | Value   | Health                |
         ---------------------------------------------------------------- 
        | 0x0b      | Temp On-Board    | 32.00   | Healthy               |
        | 0x0c      | Temp Eth Switch  | 34.00   | Healthy               |
        | 0x0d      | Temp Quad Phy    | 39.00   | Healthy               |
        | 0x0e      | Temp Inlet       | 26.00   | Healthy               |
        | 0x0f      | Temp Phy 10G     | 54.00   | Healthy               |
        | 0x10      | Vcc +12V In      | 12.12   | Healthy               |
        | 0x11      | Vcc +5V SUS      | 5.08    | Healthy               |
        | 0x12      | Vcc +3.3V SUS    | 3.29    | Healthy               |
        | 0x13      | Vcc +1.8V SUS    | 1.78    | Healthy               |
        | 0x14      | Vcc +1.5V SUS    | 1.50    | Healthy               |
        | 0x15      | Vcc +1.25V SUS   | 1.24    | Healthy               |
        | 0x16      | Vcc +1.2V SUS    | 1.19    | Healthy               |
        | 0x17      | Vcc +0.75V SUS   | 0.75    | Healthy               |
        | 0x18      | Vcc +3.3V        | 3.28    | Healthy               |
        | 0x19      | Vcc +2.5V        | 2.48    | Healthy               |
        | 0x1a      | Vcc +1.8V        | 1.78    | Healthy               |
        | 0x1b      | Vcc +1.2V        | 1.21    | Healthy               |
        | 0x1c      | Vcc +1.0V        | 1.01    | Healthy               |
        | 0x1d      | Vbat +3V         | 3.07    | Healthy               |
        | 0x3f      | Power Good Latch | 0x8001  | Healthy               |
        | 0x40      | FPGA RW Status   | 0x8002  | Healthy               |
        | 0x41      | FPGA Heartbeat   | 0x8002  | Healthy               |
        | 0x48      | ShMC Redun State | 0x8002  | Healthy               |
Hotswap Status: Active
Product name: MSH8900
Part number: T4301X_2-X
Serial number: 9017017638
Manufacturing date: Wed Dec 19 14:35:00 2018
Type: HubNode
Status: Active
Model: MSH8900
HPM versions:
	BMC: 3.16.09289D46
	FPGA: 2.6.00000000
Management Network:
        Management MAC: 00:a0:a5:d2:27:79
        IP Source: dhcp
        IP: 10.28.47.171
        Subnet: 255.255.255.0
        Gateway: 10.28.47.3
        VLAN: FFD
Payload IPs :
	Network Interfaces:
		Id: 1, 
		Backplane: Unknown, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:d2:27:79
		IP Source: static

================================

================================
Name: HubNode 2
Health: Healthy
Health Details: 
        | Sensor ID | Sensor Name      | Value   | Health                |
         ---------------------------------------------------------------- 
        | 0x0b      | Temp On-Board    | 33.00   | Healthy               |
        | 0x0c      | Temp Eth Switch  | 34.00   | Healthy               |
        | 0x0d      | Temp Quad Phy    | 40.00   | Healthy               |
        | 0x0e      | Temp Inlet       | 27.00   | Healthy               |
        | 0x0f      | Temp Phy 10G     | 54.00   | Healthy               |
        | 0x10      | Vcc +12V In      | 12.12   | Healthy               |
        | 0x11      | Vcc +5V SUS      | 5.05    | Healthy               |
        | 0x12      | Vcc +3.3V SUS    | 3.29    | Healthy               |
        | 0x13      | Vcc +1.8V SUS    | 1.78    | Healthy               |
        | 0x14      | Vcc +1.5V SUS    | 1.50    | Healthy               |
        | 0x15      | Vcc +1.25V SUS   | 1.24    | Healthy               |
        | 0x16      | Vcc +1.2V SUS    | 1.19    | Healthy               |
        | 0x17      | Vcc +0.75V SUS   | 0.75    | Healthy               |
        | 0x18      | Vcc +3.3V        | 3.29    | Healthy               |
        | 0x19      | Vcc +2.5V        | 2.48    | Healthy               |
        | 0x1a      | Vcc +1.8V        | 1.78    | Healthy               |
        | 0x1b      | Vcc +1.2V        | 1.21    | Healthy               |
        | 0x1c      | Vcc +1.0V        | 1.01    | Healthy               |
        | 0x1d      | Vbat +3V         | 3.07    | Healthy               |
        | 0x3f      | Power Good Latch | 0x8001  | Healthy               |
        | 0x40      | FPGA RW Status   | 0x8002  | Healthy               |
        | 0x41      | FPGA Heartbeat   | 0x8002  | Healthy               |
        | 0x48      | ShMC Redun State | 0x8008  | Healthy               |
Hotswap Status: Active
Product name: MSH8900
Part number: T4301X_2-X
Serial number: 9017017717
Manufacturing date: Wed Dec 19 14:21:00 2018
Type: HubNode
Status: Standby
Model: MSH8900
HPM versions:
	BMC: 3.16.09289D46
	FPGA: 2.6.00000000
Management Network:
        Management MAC: 00:a0:a5:d2:30:41
        IP Source: dhcp
        IP: 10.28.47.66
        Subnet: 255.255.255.0
        Gateway: 10.28.47.3
        VLAN: FFD
Payload IPs :
	Network Interfaces:
		Id: 1, 
		Backplane: Unknown, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:d2:30:41
		IP Source: static

================================

*******************************
Nodes
*******************************

================================
SLOT #1
================================
Name: Node 1
Health: Healthy
Health Details: 
        | Sensor ID | Sensor Name      | Value   | Health                |
         ---------------------------------------------------------------- 
        | 0x0e      | Vcc +12V SUS     | 12.06   | Healthy               |
        | 0x0f      | Vcc +5V SUS      | 4.96    | Healthy               |
        | 0x10      | Vcc +2.5V SUS    | 2.49    | Healthy               |
        | 0x11      | Vcc +1.8V SUS    | 1.81    | Healthy               |
        | 0x12      | Vcc +1.5V SUS    | 1.50    | Healthy               |
        | 0x13      | Vcc +1.25V SUS   | 1.26    | Healthy               |
        | 0x14      | Vcc +0.75V SUS   | 0.75    | Healthy               |
        | 0x04      | Temp Inlet       | 26.00   | Healthy               |
        | 0x05      | Temp Outlet      | 27.00   | Healthy               |
        | 0x07      | Temp BMC         | 34.00   | Healthy               |
        | 0x08      | Temp CPU 1       | 0.00    | Healthy               |
        | 0x09      | Temp CPU 2       | 0.00    | Healthy               |
Hotswap Status: Active
Product name: 4009
Part number: 1062-0224
Serial number: 9017019211
Manufacturing date: Fri Dec 21 18:03:00 2018
Type: Node
Model: MSP805x
HPM versions:
	BMC: 1.6.09289DBB
	FPGA: 1.0.00000000
	BIOS: 1.5.0926BD66
Management Network:
        Management MAC: 00:a0:a5:d2:e8:e4
        IP Source: dhcp
        IP: 10.28.47.136
        Subnet: 255.255.255.0
        Gateway: 10.28.47.3
        VLAN: FFD
Payload IPs :
	Network Interfaces:
		Id: 1, 
		Backplane: Base2, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:d2:e8:de
		IP Source: static


		Id: 2, 
		Backplane: Fabric1p1, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:d2:e8:df
		IP Source: static


		Id: 3, 
		Backplane: Fabric2p2, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:d2:e8:e0
		IP Source: static


	Network Interfaces:
		Id: 1, 
		Backplane: Base1, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:d2:e8:e1
		IP Source: static


		Id: 2, 
		Backplane: Fabric1p2, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:d2:e8:e2
		IP Source: static


		Id: 3, 
		Backplane: Fabric2p1, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:d2:e8:e3
		IP Source: static

================================

================================
SLOT #2
================================
Name: Node 2
Health: Healthy
Health Details: 
        | Sensor ID | Sensor Name      | Value   | Health                |
         ---------------------------------------------------------------- 
        | 0x0e      | Vcc +12V SUS     | 12.06   | Healthy               |
        | 0x0f      | Vcc +5V SUS      | 5.03    | Healthy               |
        | 0x10      | Vcc +2.5V SUS    | 2.47    | Healthy               |
        | 0x11      | Vcc +1.8V SUS    | 1.81    | Healthy               |
        | 0x12      | Vcc +1.5V SUS    | 1.49    | Healthy               |
        | 0x13      | Vcc +1.25V SUS   | 1.25    | Healthy               |
        | 0x14      | Vcc +0.75V SUS   | 0.75    | Healthy               |
        | 0x04      | Temp Inlet       | 25.00   | Healthy               |
        | 0x05      | Temp Outlet      | 27.00   | Healthy               |
        | 0x07      | Temp BMC         | 34.00   | Healthy               |
        | 0x08      | Temp CPU 1       | 0.00    | Healthy               |
        | 0x09      | Temp CPU 2       | 0.00    | Healthy               |
Hotswap Status: Active
Product name: 4009
Part number: 1062-0224
Serial number: 9017019352
Manufacturing date: Fri Dec 21 18:02:00 2018
Type: Node
Model: MSP805x
HPM versions:
	BMC: 1.6.09289DBB
	FPGA: 1.0.00000000
	BIOS: 1.5.0926BD66
Management Network:
        Management MAC: 00:a0:a5:d3:1a:08
        IP Source: dhcp
        IP: 10.28.47.100
        Subnet: 255.255.255.0
        Gateway: 10.28.47.3
        VLAN: FFD
Payload IPs :
	Network Interfaces:
		Id: 1, 
		Backplane: Base2, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:d3:1a:02
		IP Source: static


		Id: 2, 
		Backplane: Fabric1p1, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:d3:1a:03
		IP Source: static


		Id: 3, 
		Backplane: Fabric2p2, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:d3:1a:04
		IP Source: static


	Network Interfaces:
		Id: 1, 
		Backplane: Base1, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:d3:1a:05
		IP Source: static


		Id: 2, 
		Backplane: Fabric1p2, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:d3:1a:06
		IP Source: static


		Id: 3, 
		Backplane: Fabric2p1, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:d3:1a:07
		IP Source: static

================================

================================
SLOT #3
================================
Name: Node 3
Health: Healthy
Health Details: 
        | Sensor ID | Sensor Name      | Value   | Health                |
         ---------------------------------------------------------------- 
        | 0x0e      | Vcc +12V SUS     | 12.06   | Healthy               |
        | 0x0f      | Vcc +5V SUS      | 5.01    | Healthy               |
        | 0x10      | Vcc +2.5V SUS    | 2.48    | Healthy               |
        | 0x11      | Vcc +1.8V SUS    | 1.81    | Healthy               |
        | 0x12      | Vcc +1.5V SUS    | 1.49    | Healthy               |
        | 0x13      | Vcc +1.25V SUS   | 1.24    | Healthy               |
        | 0x14      | Vcc +0.75V SUS   | 0.75    | Healthy               |
        | 0x04      | Temp Inlet       | 25.00   | Healthy               |
        | 0x05      | Temp Outlet      | 26.00   | Healthy               |
        | 0x07      | Temp BMC         | 33.00   | Healthy               |
        | 0x08      | Temp CPU 1       | 0.00    | Healthy               |
        | 0x09      | Temp CPU 2       | 0.00    | Healthy               |
Hotswap Status: Active
Product name: 4009
Part number: 1062-0224
Serial number: 9017019304
Manufacturing date: Fri Dec 21 18:12:00 2018
Type: Node
Model: MSP805x
HPM versions:
	BMC: 1.6.09289DBB
	FPGA: 1.0.00000000
	BIOS: 1.5.0926BD66
Management Network:
        Management MAC: 00:a0:a5:d3:1b:a0
        IP Source: dhcp
        IP: 10.28.47.64
        Subnet: 255.255.255.0
        Gateway: 10.28.47.3
        VLAN: FFD
Payload IPs :
	Network Interfaces:
		Id: 1, 
		Backplane: Base2, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:d3:1b:9a
		IP Source: static


		Id: 2, 
		Backplane: Fabric1p1, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:d3:1b:9b
		IP Source: static


		Id: 3, 
		Backplane: Fabric2p2, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:d3:1b:9c
		IP Source: static


	Network Interfaces:
		Id: 1, 
		Backplane: Base1, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:d3:1b:9d
		IP Source: static


		Id: 2, 
		Backplane: Fabric1p2, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:d3:1b:9e
		IP Source: static


		Id: 3, 
		Backplane: Fabric2p1, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:d3:1b:9f
		IP Source: static

================================

================================
SLOT #4
================================
Name: Node 4
Health: Healthy
Health Details: 
        | Sensor ID | Sensor Name      | Value   | Health                |
         ---------------------------------------------------------------- 
        | 0x0e      | Vcc +12V SUS     | 12.06   | Healthy               |
        | 0x0f      | Vcc +5V SUS      | 5.01    | Healthy               |
        | 0x10      | Vcc +2.5V SUS    | 2.49    | Healthy               |
        | 0x11      | Vcc +1.8V SUS    | 1.81    | Healthy               |
        | 0x12      | Vcc +1.5V SUS    | 1.49    | Healthy               |
        | 0x13      | Vcc +1.25V SUS   | 1.25    | Healthy               |
        | 0x14      | Vcc +0.75V SUS   | 0.76    | Healthy               |
        | 0x04      | Temp Inlet       | 25.00   | Healthy               |
        | 0x05      | Temp Outlet      | 26.00   | Healthy               |
        | 0x07      | Temp BMC         | 34.00   | Healthy               |
        | 0x08      | Temp CPU 1       | 0.00    | Healthy               |
        | 0x09      | Temp CPU 2       | 0.00    | Healthy               |
Hotswap Status: Active
Product name: 4009
Part number: 1062-0224
Serial number: 9017016499
Manufacturing date: Fri Dec 21 17:28:00 2018
Type: Node
Model: MSP805x
HPM versions:
	BMC: 1.6.09289DBB
	FPGA: 1.0.00000000
	BIOS: 1.5.0926BD66
Management Network:
        Management MAC: 00:a0:a5:d2:48:6c
        IP Source: dhcp
        IP: 10.28.47.116
        Subnet: 255.255.255.0
        Gateway: 10.28.47.3
        VLAN: FFD
Payload IPs :
	Network Interfaces:
		Id: 1, 
		Backplane: Base2, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:d2:48:66
		IP Source: static


		Id: 2, 
		Backplane: Fabric1p1, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:d2:48:67
		IP Source: static


		Id: 3, 
		Backplane: Fabric2p2, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:d2:48:68
		IP Source: static


	Network Interfaces:
		Id: 1, 
		Backplane: Base1, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:d2:48:69
		IP Source: static


		Id: 2, 
		Backplane: Fabric1p2, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:d2:48:6a
		IP Source: static


		Id: 3, 
		Backplane: Fabric2p1, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:d2:48:6b
		IP Source: static

================================

================================
SLOT #5
================================
Name: Node 5
Health: Healthy
Health Details: 
        | Sensor ID | Sensor Name      | Value   | Health                |
         ---------------------------------------------------------------- 
        | 0x0e      | Vcc +12V SUS     | 12.06   | Healthy               |
        | 0x0f      | Vcc +5V SUS      | 4.96    | Healthy               |
        | 0x10      | Vcc +2.5V SUS    | 2.50    | Healthy               |
        | 0x11      | Vcc +1.8V SUS    | 1.81    | Healthy               |
        | 0x12      | Vcc +1.5V SUS    | 1.49    | Healthy               |
        | 0x13      | Vcc +1.25V SUS   | 1.25    | Healthy               |
        | 0x14      | Vcc +0.75V SUS   | 0.75    | Healthy               |
        | 0x04      | Temp Inlet       | 25.00   | Healthy               |
        | 0x05      | Temp Outlet      | 27.00   | Healthy               |
        | 0x07      | Temp BMC         | 33.00   | Healthy               |
        | 0x08      | Temp CPU 1       | 0.00    | Healthy               |
        | 0x09      | Temp CPU 2       | 0.00    | Healthy               |
Hotswap Status: Active
Product name: 4009
Part number: 1062-0224
Serial number: 9017016633
Manufacturing date: Fri Dec 21 17:29:00 2018
Type: Node
Model: MSP805x
HPM versions:
	BMC: 1.6.09289DBB
	FPGA: 1.0.00000000
	BIOS: 1.5.0926BD66
Management Network:
        Management MAC: 00:a0:a5:d2:47:2c
        IP Source: dhcp
        IP: 10.28.47.118
        Subnet: 255.255.255.0
        Gateway: 10.28.47.3
        VLAN: FFD
Payload IPs :
	Network Interfaces:
		Id: 1, 
		Backplane: Base2, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:d2:47:26
		IP Source: static


		Id: 2, 
		Backplane: Fabric1p1, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:d2:47:27
		IP Source: static


		Id: 3, 
		Backplane: Fabric2p2, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:d2:47:28
		IP Source: static


	Network Interfaces:
		Id: 1, 
		Backplane: Base1, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:d2:47:29
		IP Source: static


		Id: 2, 
		Backplane: Fabric1p2, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:d2:47:2a
		IP Source: static


		Id: 3, 
		Backplane: Fabric2p1, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:d2:47:2b
		IP Source: static

================================

================================
SLOT #6
================================
Name: Node 6
Health: Healthy
Health Details: 
        | Sensor ID | Sensor Name      | Value   | Health                |
         ---------------------------------------------------------------- 
        | 0x0e      | Vcc +12V SUS     | 12.06   | Healthy               |
        | 0x0f      | Vcc +5V SUS      | 4.98    | Healthy               |
        | 0x10      | Vcc +2.5V SUS    | 2.50    | Healthy               |
        | 0x11      | Vcc +1.8V SUS    | 1.80    | Healthy               |
        | 0x12      | Vcc +1.5V SUS    | 1.50    | Healthy               |
        | 0x13      | Vcc +1.25V SUS   | 1.24    | Healthy               |
        | 0x14      | Vcc +0.75V SUS   | 0.76    | Healthy               |
        | 0x04      | Temp Inlet       | 25.00   | Healthy               |
        | 0x05      | Temp Outlet      | 26.00   | Healthy               |
        | 0x07      | Temp BMC         | 33.00   | Healthy               |
        | 0x08      | Temp CPU 1       | 0.00    | Healthy               |
        | 0x09      | Temp CPU 2       | 0.00    | Healthy               |
Hotswap Status: Active
Product name: 4009
Part number: 1062-0224
Serial number: 9017019256
Manufacturing date: Fri Dec 21 17:32:00 2018
Type: Node
Model: MSP805x
HPM versions:
	BMC: 1.6.09289DBB
	FPGA: 1.0.00000000
	BIOS: 1.5.0926BD66
Management Network:
        Management MAC: 00:a0:a5:d3:1c:30
        IP Source: dhcp
        IP: 10.28.47.99
        Subnet: 255.255.255.0
        Gateway: 10.28.47.3
        VLAN: FFD
Payload IPs :
	Network Interfaces:
		Id: 1, 
		Backplane: Base2, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:d3:1c:2a
		IP Source: static


		Id: 2, 
		Backplane: Fabric1p1, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:d3:1c:2b
		IP Source: static


		Id: 3, 
		Backplane: Fabric2p2, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:d3:1c:2c
		IP Source: static


	Network Interfaces:
		Id: 1, 
		Backplane: Base1, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:d3:1c:2d
		IP Source: static


		Id: 2, 
		Backplane: Fabric1p2, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:d3:1c:2e
		IP Source: static


		Id: 3, 
		Backplane: Fabric2p1, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:d3:1c:2f
		IP Source: static

================================

================================
SLOT #7
================================
Name: Node 7
Health: Healthy
Health Details: 
        | Sensor ID | Sensor Name      | Value   | Health                |
         ---------------------------------------------------------------- 
        | 0x0e      | Vcc +12V SUS     | 12.06   | Healthy               |
        | 0x0f      | Vcc +5V SUS      | 5.01    | Healthy               |
        | 0x10      | Vcc +2.5V SUS    | 2.49    | Healthy               |
        | 0x11      | Vcc +1.8V SUS    | 1.80    | Healthy               |
        | 0x12      | Vcc +1.5V SUS    | 1.50    | Healthy               |
        | 0x13      | Vcc +1.25V SUS   | 1.24    | Healthy               |
        | 0x14      | Vcc +0.75V SUS   | 0.75    | Healthy               |
        | 0x04      | Temp Inlet       | 26.00   | Healthy               |
        | 0x05      | Temp Outlet      | 27.00   | Healthy               |
        | 0x07      | Temp BMC         | 34.00   | Healthy               |
        | 0x08      | Temp CPU 1       | 0.00    | Healthy               |
        | 0x09      | Temp CPU 2       | 0.00    | Healthy               |
Hotswap Status: Active
Product name: 4009
Part number: 1062-0224
Serial number: 9017019263
Manufacturing date: Fri Dec 21 17:33:00 2018
Type: Node
Model: MSP805x
HPM versions:
	BMC: 1.6.09289DBB
	FPGA: 1.0.00000000
	BIOS: 1.5.0926BD66
Management Network:
        Management MAC: 00:a0:a5:d3:1b:38
        IP Source: dhcp
        IP: 10.28.47.122
        Subnet: 255.255.255.0
        Gateway: 10.28.47.3
        VLAN: FFD
Payload IPs :
	Network Interfaces:
		Id: 1, 
		Backplane: Base2, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:d3:1b:32
		IP Source: static


		Id: 2, 
		Backplane: Fabric1p1, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:d3:1b:33
		IP Source: static


		Id: 3, 
		Backplane: Fabric2p2, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:d3:1b:34
		IP Source: static


	Network Interfaces:
		Id: 1, 
		Backplane: Base1, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:d3:1b:35
		IP Source: static


		Id: 2, 
		Backplane: Fabric1p2, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:d3:1b:36
		IP Source: static


		Id: 3, 
		Backplane: Fabric2p1, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:d3:1b:37
		IP Source: static

================================

================================
SLOT #8
================================
Name: Node 8
Health: Healthy
Health Details: 
        | Sensor ID | Sensor Name      | Value   | Health                |
         ---------------------------------------------------------------- 
        | 0x0e      | Vcc +12V SUS     | 12.06   | Healthy               |
        | 0x0f      | Vcc +5V SUS      | 5.03    | Healthy               |
        | 0x10      | Vcc +2.5V SUS    | 2.48    | Healthy               |
        | 0x11      | Vcc +1.8V SUS    | 1.81    | Healthy               |
        | 0x12      | Vcc +1.5V SUS    | 1.50    | Healthy               |
        | 0x13      | Vcc +1.25V SUS   | 1.26    | Healthy               |
        | 0x14      | Vcc +0.75V SUS   | 0.75    | Healthy               |
        | 0x04      | Temp Inlet       | 25.00   | Healthy               |
        | 0x05      | Temp Outlet      | 26.00   | Healthy               |
        | 0x07      | Temp BMC         | 33.00   | Healthy               |
        | 0x08      | Temp CPU 1       | 0.00    | Healthy               |
        | 0x09      | Temp CPU 2       | 0.00    | Healthy               |
Hotswap Status: Active
Product name: 4009
Part number: 1062-0224
Serial number: 9017019347
Manufacturing date: Fri Dec 21 17:33:00 2018
Type: Node
Model: MSP805x
HPM versions:
	BMC: 1.6.09289DBB
	FPGA: 1.0.00000000
	BIOS: 1.5.0926BD66
Management Network:
        Management MAC: 00:a0:a5:d3:1b:d0
        IP Source: dhcp
        IP: 10.28.47.141
        Subnet: 255.255.255.0
        Gateway: 10.28.47.3
        VLAN: FFD
Payload IPs :
	Network Interfaces:
		Id: 1, 
		Backplane: Base2, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:d3:1b:ca
		IP Source: static


		Id: 2, 
		Backplane: Fabric1p1, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:d3:1b:cb
		IP Source: static


		Id: 3, 
		Backplane: Fabric2p2, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:d3:1b:cc
		IP Source: static


	Network Interfaces:
		Id: 1, 
		Backplane: Base1, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:d3:1b:cd
		IP Source: static


		Id: 2, 
		Backplane: Fabric1p2, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:d3:1b:ce
		IP Source: static


		Id: 3, 
		Backplane: Fabric2p1, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:d3:1b:cf
		IP Source: static

================================

================================
SLOT #9
================================
Name: Node 9
Health: Healthy
Health Details: 
        | Sensor ID | Sensor Name      | Value   | Health                |
         ---------------------------------------------------------------- 
        | 0x0e      | Vcc +12V SUS     | 12.06   | Healthy               |
        | 0x0f      | Vcc +5V SUS      | 5.03    | Healthy               |
        | 0x10      | Vcc +2.5V SUS    | 2.49    | Healthy               |
        | 0x11      | Vcc +1.8V SUS    | 1.81    | Healthy               |
        | 0x12      | Vcc +1.5V SUS    | 1.49    | Healthy               |
        | 0x13      | Vcc +1.25V SUS   | 1.24    | Healthy               |
        | 0x14      | Vcc +0.75V SUS   | 0.74    | Healthy               |
        | 0x04      | Temp Inlet       | 25.00   | Healthy               |
        | 0x05      | Temp Outlet      | 26.00   | Healthy               |
        | 0x07      | Temp BMC         | 33.00   | Healthy               |
        | 0x08      | Temp CPU 1       | 0.00    | Healthy               |
        | 0x09      | Temp CPU 2       | 0.00    | Healthy               |
Hotswap Status: Active
Product name: 4009
Part number: 1062-0224
Serial number: 9017019344
Manufacturing date: Fri Dec 21 17:33:00 2018
Type: Node
Model: MSP805x
HPM versions:
	BMC: 1.6.09289DBB
	FPGA: 1.0.00000000
	BIOS: 1.5.0926BD66
Management Network:
        Management MAC: 00:a0:a5:d3:1b:98
        IP Source: dhcp
        IP: 10.28.47.133
        Subnet: 255.255.255.0
        Gateway: 10.28.47.3
        VLAN: FFD
Payload IPs :
	Network Interfaces:
		Id: 1, 
		Backplane: Base2, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:d3:1b:92
		IP Source: static


		Id: 2, 
		Backplane: Fabric1p1, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:d3:1b:93
		IP Source: static


		Id: 3, 
		Backplane: Fabric2p2, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:d3:1b:94
		IP Source: static


	Network Interfaces:
		Id: 1, 
		Backplane: Base1, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:d3:1b:95
		IP Source: static


		Id: 2, 
		Backplane: Fabric1p2, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:d3:1b:96
		IP Source: static


		Id: 3, 
		Backplane: Fabric2p1, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:d3:1b:97
		IP Source: static

================================

*******************************
Original JSON string
*******************************
{ "name": "Platform #1", "number": "1", "chassis": "ms2900", "health": "Green", "fans":[ {"number": "1", "name": "Fan 1", "type": "fan", "health": "Green", "rpm": "8008","alarm": {"alarmlevel": "None"}, "LedIdentify": {"status": "off"}, "hotswapStatus":{"state": "M4", "text": "Active"}}, {"number": "2", "name": "Fan 2", "type": "fan", "health": "Green", "rpm": "8008","alarm": {"alarmlevel": "None"}, "LedIdentify": {"status": "off"}, "hotswapStatus":{"state": "M4", "text": "Active"}}, {"number": "3", "name": "Fan 3", "type": "fan", "health": "Green", "rpm": "8162","alarm": {"alarmlevel": "None"}, "LedIdentify": {"status": "off"}, "hotswapStatus":{"state": "M4", "text": "Active"}}, {"number": "4", "name": "Fan 4", "type": "fan", "health": "Green", "rpm": "8239","alarm": {"alarmlevel": "None"}, "LedIdentify": {"status": "off"}, "hotswapStatus":{"state": "M4", "text": "Active"}}, {"number": "5", "name": "Fan 5", "type": "fan", "health": "Green", "rpm": "8239","alarm": {"alarmlevel": "None"}, "LedIdentify": {"status": "off"}, "hotswapStatus":{"state": "M4", "text": "Active"}} ], "type": "platform", "components": [{"number": "10", "name": "HubNode 1", "health": "Green", "fruInfo": {"mfgDate": "Wed Dec 19 14:35:00 2018", "boardMfg": "Kontron", "boardProductName": "MSH8900", "boardProductPart": "T4301X_2-X", "boardSerialNumber": "9017017638"},"hotswapStatus":{"state": "M4", "text": "Active"},"type":"hubnode", "HubNodeFeatures":{"SwitchSpeedSupport": "1", "PortModeSupport": "0"}, "versions" : [{ "name" : "BMC", "major" : "3", "minor" : "16", "revision" : "09289D46"},{ "name" : "FPGA", "major" : "2", "minor" : "06", "revision" : "00000000"}],"model": "MSH8900", "isUpdating" : "0", "managementIP": "10.28.47.171", "managementMAC": "00:a0:a5:d2:27:79", "alarm": {"alarmlevel": "None", "sensors":[]}, "LedIdentify": {"status": "off"}, "components": [{ "description": "Switch 1", "number": "1", "hotswapStatus":{"state": "M4", "text": "Active"}, "networkInterfaces": [{ "id": "1", "backplane": "Unknown", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:d2:27:79"}]}], "status": "Active"}, {"number": "11", "name": "HubNode 2", "health": "Green", "fruInfo": {"mfgDate": "Wed Dec 19 14:21:00 2018", "boardMfg": "Kontron", "boardProductName": "MSH8900", "boardProductPart": "T4301X_2-X", "boardSerialNumber": "9017017717"},"hotswapStatus":{"state": "M4", "text": "Active"},"type":"hubnode", "HubNodeFeatures":{"SwitchSpeedSupport": "1", "PortModeSupport": "0"}, "versions" : [{ "name" : "BMC", "major" : "3", "minor" : "16", "revision" : "09289D46"},{ "name" : "FPGA", "major" : "2", "minor" : "06", "revision" : "00000000"}],"model": "MSH8900", "isUpdating" : "0", "managementIP": "10.28.47.66", "managementMAC": "00:a0:a5:d2:30:41", "alarm": {"alarmlevel": "None", "sensors":[]}, "LedIdentify": {"status": "off"}, "components": [{ "description": "Switch 2", "number": "1", "hotswapStatus":{"state": "M4", "text": "Active"}, "networkInterfaces": [{ "id": "1", "backplane": "Unknown", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:d2:30:41"}]}], "status": "Standby"}, {"number": "1", "name": "Node 1", "health": "Green", "fruInfo": {"mfgDate": "Fri Dec 21 18:03:00 2018", "boardMfg": "Kontron", "boardProductName": "4009", "boardProductPart": "1062-0224", "boardSerialNumber": "9017019211"},"hotswapStatus":{"state": "M4", "text": "Active"},"type":"node", "versions" : [{ "name" : "BMC", "major" : "1", "minor" : "06", "revision" : "09289DBB"},{ "name" : "FPGA", "major" : "1", "minor" : "00", "revision" : "00000000"},{ "name" : "BIOS", "major" : "1", "minor" : "05", "revision" : "0926BD66"}],"model": "MSP805x", "isUpdating" : "0", "managementIP": "10.28.47.136", "managementMAC": "00:a0:a5:d2:e8:e4", "alarm": {"alarmlevel": "None", "sensors":[]}, "LedIdentify": {"status": "off"}, "components": [{ "description": "Payload1       ", "number": "1", "hotswapStatus":{"state": "M1", "text": "Inactive"}, "networkInterfaces": [{ "id": "1", "backplane": "Base2", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:d2:e8:de"}, { "id": "2", "backplane": "Fabric1p1", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:d2:e8:df"}, { "id": "3", "backplane": "Fabric2p2", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:d2:e8:e0"}]}, { "description": "Payload2       ", "number": "2", "hotswapStatus":{"state": "M1", "text": "Inactive"}, "networkInterfaces": [{ "id": "1", "backplane": "Base1", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:d2:e8:e1"}, { "id": "2", "backplane": "Fabric1p2", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:d2:e8:e2"}, { "id": "3", "backplane": "Fabric2p1", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:d2:e8:e3"}]}] }, {"number": "2", "name": "Node 2", "health": "Green", "fruInfo": {"mfgDate": "Fri Dec 21 18:02:00 2018", "boardMfg": "Kontron", "boardProductName": "4009", "boardProductPart": "1062-0224", "boardSerialNumber": "9017019352"},"hotswapStatus":{"state": "M4", "text": "Active"},"type":"node", "versions" : [{ "name" : "BMC", "major" : "1", "minor" : "06", "revision" : "09289DBB"},{ "name" : "FPGA", "major" : "1", "minor" : "00", "revision" : "00000000"},{ "name" : "BIOS", "major" : "1", "minor" : "05", "revision" : "0926BD66"}],"model": "MSP805x", "isUpdating" : "0", "managementIP": "10.28.47.100", "managementMAC": "00:a0:a5:d3:1a:08", "alarm": {"alarmlevel": "None", "sensors":[]}, "LedIdentify": {"status": "off"}, "components": [{ "description": "Payload1       ", "number": "1", "hotswapStatus":{"state": "M1", "text": "Inactive"}, "networkInterfaces": [{ "id": "1", "backplane": "Base2", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:d3:1a:02"}, { "id": "2", "backplane": "Fabric1p1", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:d3:1a:03"}, { "id": "3", "backplane": "Fabric2p2", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:d3:1a:04"}]}, { "description": "Payload2       ", "number": "2", "hotswapStatus":{"state": "M1", "text": "Inactive"}, "networkInterfaces": [{ "id": "1", "backplane": "Base1", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:d3:1a:05"}, { "id": "2", "backplane": "Fabric1p2", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:d3:1a:06"}, { "id": "3", "backplane": "Fabric2p1", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:d3:1a:07"}]}] }, {"number": "3", "name": "Node 3", "health": "Green", "fruInfo": {"mfgDate": "Fri Dec 21 18:12:00 2018", "boardMfg": "Kontron", "boardProductName": "4009", "boardProductPart": "1062-0224", "boardSerialNumber": "9017019304"},"hotswapStatus":{"state": "M4", "text": "Active"},"type":"node", "versions" : [{ "name" : "BMC", "major" : "1", "minor" : "06", "revision" : "09289DBB"},{ "name" : "FPGA", "major" : "1", "minor" : "00", "revision" : "00000000"},{ "name" : "BIOS", "major" : "1", "minor" : "05", "revision" : "0926BD66"}],"model": "MSP805x", "isUpdating" : "0", "managementIP": "10.28.47.64", "managementMAC": "00:a0:a5:d3:1b:a0", "alarm": {"alarmlevel": "None", "sensors":[]}, "LedIdentify": {"status": "off"}, "components": [{ "description": "Payload1       ", "number": "1", "hotswapStatus":{"state": "M1", "text": "Inactive"}, "networkInterfaces": [{ "id": "1", "backplane": "Base2", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:d3:1b:9a"}, { "id": "2", "backplane": "Fabric1p1", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:d3:1b:9b"}, { "id": "3", "backplane": "Fabric2p2", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:d3:1b:9c"}]}, { "description": "Payload2       ", "number": "2", "hotswapStatus":{"state": "M1", "text": "Inactive"}, "networkInterfaces": [{ "id": "1", "backplane": "Base1", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:d3:1b:9d"}, { "id": "2", "backplane": "Fabric1p2", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:d3:1b:9e"}, { "id": "3", "backplane": "Fabric2p1", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:d3:1b:9f"}]}] }, {"number": "4", "name": "Node 4", "health": "Green", "fruInfo": {"mfgDate": "Fri Dec 21 17:28:00 2018", "boardMfg": "Kontron", "boardProductName": "4009", "boardProductPart": "1062-0224", "boardSerialNumber": "9017016499"},"hotswapStatus":{"state": "M4", "text": "Active"},"type":"node", "versions" : [{ "name" : "BMC", "major" : "1", "minor" : "06", "revision" : "09289DBB"},{ "name" : "FPGA", "major" : "1", "minor" : "00", "revision" : "00000000"},{ "name" : "BIOS", "major" : "1", "minor" : "05", "revision" : "0926BD66"}],"model": "MSP805x", "isUpdating" : "0", "managementIP": "10.28.47.116", "managementMAC": "00:a0:a5:d2:48:6c", "alarm": {"alarmlevel": "None", "sensors":[]}, "LedIdentify": {"status": "off"}, "components": [{ "description": "Payload1       ", "number": "1", "hotswapStatus":{"state": "M1", "text": "Inactive"}, "networkInterfaces": [{ "id": "1", "backplane": "Base2", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:d2:48:66"}, { "id": "2", "backplane": "Fabric1p1", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:d2:48:67"}, { "id": "3", "backplane": "Fabric2p2", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:d2:48:68"}]}, { "description": "Payload2       ", "number": "2", "hotswapStatus":{"state": "M1", "text": "Inactive"}, "networkInterfaces": [{ "id": "1", "backplane": "Base1", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:d2:48:69"}, { "id": "2", "backplane": "Fabric1p2", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:d2:48:6a"}, { "id": "3", "backplane": "Fabric2p1", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:d2:48:6b"}]}] }, {"number": "5", "name": "Node 5", "health": "Green", "fruInfo": {"mfgDate": "Fri Dec 21 17:29:00 2018", "boardMfg": "Kontron", "boardProductName": "4009", "boardProductPart": "1062-0224", "boardSerialNumber": "9017016633"},"hotswapStatus":{"state": "M4", "text": "Active"},"type":"node", "versions" : [{ "name" : "BMC", "major" : "1", "minor" : "06", "revision" : "09289DBB"},{ "name" : "FPGA", "major" : "1", "minor" : "00", "revision" : "00000000"},{ "name" : "BIOS", "major" : "1", "minor" : "05", "revision" : "0926BD66"}],"model": "MSP805x", "isUpdating" : "0", "managementIP": "10.28.47.118", "managementMAC": "00:a0:a5:d2:47:2c", "alarm": {"alarmlevel": "None", "sensors":[]}, "LedIdentify": {"status": "off"}, "components": [{ "description": "Payload1       ", "number": "1", "hotswapStatus":{"state": "M1", "text": "Inactive"}, "networkInterfaces": [{ "id": "1", "backplane": "Base2", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:d2:47:26"}, { "id": "2", "backplane": "Fabric1p1", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:d2:47:27"}, { "id": "3", "backplane": "Fabric2p2", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:d2:47:28"}]}, { "description": "Payload2       ", "number": "2", "hotswapStatus":{"state": "M1", "text": "Inactive"}, "networkInterfaces": [{ "id": "1", "backplane": "Base1", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:d2:47:29"}, { "id": "2", "backplane": "Fabric1p2", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:d2:47:2a"}, { "id": "3", "backplane": "Fabric2p1", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:d2:47:2b"}]}] }, {"number": "6", "name": "Node 6", "health": "Green", "fruInfo": {"mfgDate": "Fri Dec 21 17:32:00 2018", "boardMfg": "Kontron", "boardProductName": "4009", "boardProductPart": "1062-0224", "boardSerialNumber": "9017019256"},"hotswapStatus":{"state": "M4", "text": "Active"},"type":"node", "versions" : [{ "name" : "BMC", "major" : "1", "minor" : "06", "revision" : "09289DBB"},{ "name" : "FPGA", "major" : "1", "minor" : "00", "revision" : "00000000"},{ "name" : "BIOS", "major" : "1", "minor" : "05", "revision" : "0926BD66"}],"model": "MSP805x", "isUpdating" : "0", "managementIP": "10.28.47.99", "managementMAC": "00:a0:a5:d3:1c:30", "alarm": {"alarmlevel": "None", "sensors":[]}, "LedIdentify": {"status": "off"}, "components": [{ "description": "Payload1       ", "number": "1", "hotswapStatus":{"state": "M1", "text": "Inactive"}, "networkInterfaces": [{ "id": "1", "backplane": "Base2", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:d3:1c:2a"}, { "id": "2", "backplane": "Fabric1p1", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:d3:1c:2b"}, { "id": "3", "backplane": "Fabric2p2", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:d3:1c:2c"}]}, { "description": "Payload2       ", "number": "2", "hotswapStatus":{"state": "M1", "text": "Inactive"}, "networkInterfaces": [{ "id": "1", "backplane": "Base1", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:d3:1c:2d"}, { "id": "2", "backplane": "Fabric1p2", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:d3:1c:2e"}, { "id": "3", "backplane": "Fabric2p1", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:d3:1c:2f"}]}] }, {"number": "7", "name": "Node 7", "health": "Green", "fruInfo": {"mfgDate": "Fri Dec 21 17:33:00 2018", "boardMfg": "Kontron", "boardProductName": "4009", "boardProductPart": "1062-0224", "boardSerialNumber": "9017019263"},"hotswapStatus":{"state": "M4", "text": "Active"},"type":"node", "versions" : [{ "name" : "BMC", "major" : "1", "minor" : "06", "revision" : "09289DBB"},{ "name" : "FPGA", "major" : "1", "minor" : "00", "revision" : "00000000"},{ "name" : "BIOS", "major" : "1", "minor" : "05", "revision" : "0926BD66"}],"model": "MSP805x", "isUpdating" : "0", "managementIP": "10.28.47.122", "managementMAC": "00:a0:a5:d3:1b:38", "alarm": {"alarmlevel": "None", "sensors":[]}, "LedIdentify": {"status": "off"}, "components": [{ "description": "Payload1       ", "number": "1", "hotswapStatus":{"state": "M1", "text": "Inactive"}, "networkInterfaces": [{ "id": "1", "backplane": "Base2", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:d3:1b:32"}, { "id": "2", "backplane": "Fabric1p1", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:d3:1b:33"}, { "id": "3", "backplane": "Fabric2p2", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:d3:1b:34"}]}, { "description": "Payload2       ", "number": "2", "hotswapStatus":{"state": "M1", "text": "Inactive"}, "networkInterfaces": [{ "id": "1", "backplane": "Base1", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:d3:1b:35"}, { "id": "2", "backplane": "Fabric1p2", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:d3:1b:36"}, { "id": "3", "backplane": "Fabric2p1", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:d3:1b:37"}]}] }, {"number": "8", "name": "Node 8", "health": "Green", "fruInfo": {"mfgDate": "Fri Dec 21 17:33:00 2018", "boardMfg": "Kontron", "boardProductName": "4009", "boardProductPart": "1062-0224", "boardSerialNumber": "9017019347"},"hotswapStatus":{"state": "M4", "text": "Active"},"type":"node", "versions" : [{ "name" : "BMC", "major" : "1", "minor" : "06", "revision" : "09289DBB"},{ "name" : "FPGA", "major" : "1", "minor" : "00", "revision" : "00000000"},{ "name" : "BIOS", "major" : "1", "minor" : "05", "revision" : "0926BD66"}],"model": "MSP805x", "isUpdating" : "0", "managementIP": "10.28.47.141", "managementMAC": "00:a0:a5:d3:1b:d0", "alarm": {"alarmlevel": "None", "sensors":[]}, "LedIdentify": {"status": "off"}, "components": [{ "description": "Payload1       ", "number": "1", "hotswapStatus":{"state": "M1", "text": "Inactive"}, "networkInterfaces": [{ "id": "1", "backplane": "Base2", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:d3:1b:ca"}, { "id": "2", "backplane": "Fabric1p1", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:d3:1b:cb"}, { "id": "3", "backplane": "Fabric2p2", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:d3:1b:cc"}]}, { "description": "Payload2       ", "number": "2", "hotswapStatus":{"state": "M1", "text": "Inactive"}, "networkInterfaces": [{ "id": "1", "backplane": "Base1", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:d3:1b:cd"}, { "id": "2", "backplane": "Fabric1p2", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:d3:1b:ce"}, { "id": "3", "backplane": "Fabric2p1", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:d3:1b:cf"}]}] }, {"number": "9", "name": "Node 9", "health": "Green", "fruInfo": {"mfgDate": "Fri Dec 21 17:33:00 2018", "boardMfg": "Kontron", "boardProductName": "4009", "boardProductPart": "1062-0224", "boardSerialNumber": "9017019344"},"hotswapStatus":{"state": "M4", "text": "Active"},"type":"node", "versions" : [{ "name" : "BMC", "major" : "1", "minor" : "06", "revision" : "09289DBB"},{ "name" : "FPGA", "major" : "1", "minor" : "00", "revision" : "00000000"},{ "name" : "BIOS", "major" : "1", "minor" : "05", "revision" : "0926BD66"}],"model": "MSP805x", "isUpdating" : "0", "managementIP": "10.28.47.133", "managementMAC": "00:a0:a5:d3:1b:98", "alarm": {"alarmlevel": "None", "sensors":[]}, "LedIdentify": {"status": "off"}, "components": [{ "description": "Payload1       ", "number": "1", "hotswapStatus":{"state": "M1", "text": "Inactive"}, "networkInterfaces": [{ "id": "1", "backplane": "Base2", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:d3:1b:92"}, { "id": "2", "backplane": "Fabric1p1", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:d3:1b:93"}, { "id": "3", "backplane": "Fabric2p2", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:d3:1b:94"}]}, { "description": "Payload2       ", "number": "2", "hotswapStatus":{"state": "M1", "text": "Inactive"}, "networkInterfaces": [{ "id": "1", "backplane": "Base1", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:d3:1b:95"}, { "id": "2", "backplane": "Fabric1p2", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:d3:1b:96"}, { "id": "3", "backplane": "Fabric2p1", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:d3:1b:97"}]}] }, { "name": "PSU", "components": [{"id": "PSU1", "number": "1", "name": "Power Supply 1", "health": "Green", "type": "psu", "hotswapStatus":{"state": "M4", "text": "Active"},"alarm": {"alarmlevel": "None"}, "tempInlet": "22.00", "tempOutlet": "28.00", "vIn": "208.00", "powerOut": "8", "powerScale": "1400","peakConsumption": "168", "averageConsumption": "8"},{"id": "PSU2", "number": "2", "name": "Power Supply 2", "health": "Green", "type": "psu", "hotswapStatus":{"state": "M4", "text": "Active"},"alarm": {"alarmlevel": "None"}, "tempInlet": "23.00", "tempOutlet": "28.00", "vIn": "208.00", "powerOut": "24", "powerScale": "1400","peakConsumption": "160", "averageConsumption": "16"}]}], "switchOID": {"oid": "1.3.6.1.4.1.6603"}, "alarm": {"alarmlevel": "None",  "components" : [ {"nodes" : [] } , {"psu" : [] }, {"fans" : [] }], "text": ""}, "LedIdentify": {"status": "off"}}