System informations
*******************************
Name: SYMKLOUD
chassis: ms2900
Health: Healthy
*******************************
Fans: 
*******************************
Fan 1: 
	Present :true
	Status :Healthy
	3080 RPM
Fan 2: 
	Present :true
	Status :Healthy
	3080 RPM
Fan 3: 
	Present :true
	Status :Healthy
	3080 RPM
Fan 4: 
	Present :true
	Status :Healthy
	3157 RPM
Fan 5: 
	Present :true
	Status :Healthy
	3080 RPM


*******************************
PSU: 
*******************************
Name: PSU 1
Health: Healthy
Health Details: No details available
Hotswap Status: Active
FRU: Informations are invalid

Name: PSU 2
Health: Healthy
Health Details: No details available
Hotswap Status: Active
FRU: Informations are invalid



*******************************
HubNodes
*******************************

================================
Name: HubNode 1
Health: Healthy
Health Details: 
        Node BMC sensors aggregated for Health Status:
        | Sensor ID | Sensor Name      | Value     | Health                |
         ------------------------------------------------------------------ 
        | 0x0b      | Temp On-Board    | 35.00     | Healthy               |
        | 0x0c      | Temp Eth Switch  | 34.00     | Healthy               |
        | 0x0d      | Temp Quad Phy    | 40.00     | Healthy               |
        | 0x0e      | Temp Inlet       | 24.00     | Healthy               |
        | 0x0f      | Temp Phy 10G     | 57.00     | Healthy               |
        | 0x10      | Vcc +12V In      | 12.18     | Healthy               |
        | 0x11      | Vcc +5V SUS      | 5.10      | Healthy               |
        | 0x12      | Vcc +3.3V SUS    | 3.31      | Healthy               |
        | 0x13      | Vcc +1.8V SUS    | 1.79      | Healthy               |
        | 0x14      | Vcc +1.5V SUS    | 1.50      | Healthy               |
        | 0x15      | Vcc +1.25V SUS   | 1.24      | Healthy               |
        | 0x16      | Vcc +1.2V SUS    | 1.18      | Healthy               |
        | 0x17      | Vcc +0.75V SUS   | 0.75      | Healthy               |
        | 0x18      | Vcc +3.3V        | 3.31      | Healthy               |
        | 0x19      | Vcc +2.5V        | 2.46      | Healthy               |
        | 0x1a      | Vcc +1.8V        | 1.79      | Healthy               |
        | 0x1b      | Vcc +1.2V        | 1.21      | Healthy               |
        | 0x1c      | Vcc +1.0V        | 1.01      | Healthy               |
        | 0x1d      | Vbat +3V         | 3.07      | Healthy               |
        | 0x3f      | Power Good Latch | 0x01 0x80 | Healthy               |
        | 0x40      | FPGA RW Status   | 0x02 0x80 | Healthy               |
        | 0x41      | FPGA Heartbeat   | 0x02 0x80 | Healthy               |
        | 0x48      | ShMC Redun State | 0x08 0x80 | Healthy               |
Hotswap Status: Active
Product name: MSH8900
Part number: T4301X_2-X
Serial number: 9013133745
Manufacturing date: Fri Sep 23 14:49:00 2016
Type: HubNode
Status: Standby
Model: MSH8900
HPM versions:
	BMC: 3.20.093AA546
	FPGA: 2.6.00000000
Management Network:
        Management MAC: 00:a0:a5:8a:8d:c7
        IP Source: dhcp
        IP: 10.24.22.104
        Subnet: 255.255.255.0
        Gateway: 10.24.22.3
        VLAN: 4093
Payload IPs :
	Network Interfaces:
		Id: 1, 
		Backplane: Management, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:8a:8d:a8
		IP Source: static

================================

================================
Name: HubNode 2
Health: Healthy
Health Details: 
        Node BMC sensors aggregated for Health Status:
        | Sensor ID | Sensor Name      | Value     | Health                |
         ------------------------------------------------------------------ 
        | 0x0b      | Temp On-Board    | 35.00     | Healthy               |
        | 0x0c      | Temp Eth Switch  | 35.00     | Healthy               |
        | 0x0d      | Temp Quad Phy    | 42.00     | Healthy               |
        | 0x0e      | Temp Inlet       | 25.00     | Healthy               |
        | 0x0f      | Temp Phy 10G     | 57.00     | Healthy               |
        | 0x10      | Vcc +12V In      | 12.06     | Healthy               |
        | 0x11      | Vcc +5V SUS      | 5.03      | Healthy               |
        | 0x12      | Vcc +3.3V SUS    | 3.31      | Healthy               |
        | 0x13      | Vcc +1.8V SUS    | 1.79      | Healthy               |
        | 0x14      | Vcc +1.5V SUS    | 1.50      | Healthy               |
        | 0x15      | Vcc +1.25V SUS   | 1.25      | Healthy               |
        | 0x16      | Vcc +1.2V SUS    | 1.19      | Healthy               |
        | 0x17      | Vcc +0.75V SUS   | 0.75      | Healthy               |
        | 0x18      | Vcc +3.3V        | 3.31      | Healthy               |
        | 0x19      | Vcc +2.5V        | 2.49      | Healthy               |
        | 0x1a      | Vcc +1.8V        | 1.78      | Healthy               |
        | 0x1b      | Vcc +1.2V        | 1.21      | Healthy               |
        | 0x1c      | Vcc +1.0V        | 1.01      | Healthy               |
        | 0x1d      | Vbat +3V         | 3.07      | Healthy               |
        | 0x3f      | Power Good Latch | 0x01 0x80 | Healthy               |
        | 0x40      | FPGA RW Status   | 0x02 0x80 | Healthy               |
        | 0x41      | FPGA Heartbeat   | 0x02 0x80 | Healthy               |
        | 0x48      | ShMC Redun State | 0x02 0x80 | Healthy               |
Hotswap Status: Active
Product name: MSH8900
Part number: T4301X_2-X
Serial number: 9013133588
Manufacturing date: Fri Sep 23 14:46:00 2016
Type: HubNode
Status: Active
Model: MSH8900
HPM versions:
	BMC: 3.20.093AA546
	FPGA: 2.6.00000000
Management Network:
        Management MAC: 00:a0:a5:91:40:25
        IP Source: dhcp
        IP: 10.24.22.132
        Subnet: 255.255.255.0
        Gateway: 10.24.22.3
        VLAN: 4093
Payload IPs :
	Network Interfaces:
		Id: 1, 
		Backplane: Management, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:91:40:06
		IP Source: static

================================

*******************************
Nodes
*******************************

================================
SLOT #1
================================
Name: Node 1
Health: Healthy
Health Details: 
        Node BMC sensors aggregated for Health Status:
        | Sensor ID | Sensor Name      | Value     | Health                |
         ------------------------------------------------------------------ 
        | 0x0e      | Vcc +12.0V SUS   | 12.18     | Healthy               |
        | 0x0f      | Vcc +3.3V SUS    | 3.35      | Healthy               |
        | 0x10      | Vcc +1.5V SUS    | 1.51      | Healthy               |
        | 0x11      | Vcc +1.2V SUS    | 1.21      | Healthy               |
        | 0x04      | Temp Brd Inlet   | 26.00     | Healthy               |
        | 0x05      | Temp Brd Outlet  | 29.00     | Healthy               |
        | 0x07      | Temp BMC         | 30.00     | Healthy               |
        | 0x08      | Temp CPU 1       | 0.00      | Healthy               |
        | 0x09      | Temp CPU 2       | 0.00      | Healthy               |
        Payload Specific Health Status (for Nodes with more than 1 payload/mmc):
            Payload 1: Healthy
            Payload 2: Healthy

Hotswap Status: Active
Product name: 4005
Part number: T4005CXXX_2-CXX
Serial number: 9013144358
Manufacturing date: Mon Sep 19 13:09:00 2016
Type: Node
Model: MSP8022
HPM versions:
	BMC: 2.21.0940E3AB
	FPGA: 3.0.00000000
	BIOS: 2.21.093A2A53
Management Network:
        Management MAC: 00:a0:a5:8c:e6:22
        IP Source: dhcp
        IP: 10.24.22.148
        Subnet: 255.255.255.0
        Gateway: 10.24.22.3
        VLAN: 4093
Payload IPs :
	Network Interfaces:
		Id: 1, 
		Backplane: Base2, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:8c:e6:1e
		IP Source: static


		Id: 2, 
		Backplane: Fabric1, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:8c:e6:1f
		IP Source: static


	Network Interfaces:
		Id: 1, 
		Backplane: Base1, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:8c:e6:20
		IP Source: static


		Id: 2, 
		Backplane: Fabric2, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:8c:e6:21
		IP Source: static

================================

================================
SLOT #2
================================
Name: Node 2
Health: Healthy
Health Details: 
        Node BMC sensors aggregated for Health Status:
        | Sensor ID | Sensor Name      | Value     | Health                |
         ------------------------------------------------------------------ 
        | 0x0e      | Vcc +12.0V SUS   | 12.18     | Healthy               |
        | 0x0f      | Vcc +3.3V SUS    | 3.34      | Healthy               |
        | 0x10      | Vcc +1.5V SUS    | 1.50      | Healthy               |
        | 0x11      | Vcc +1.2V SUS    | 1.19      | Healthy               |
        | 0x04      | Temp Brd Inlet   | 26.00     | Healthy               |
        | 0x05      | Temp Brd Outlet  | 26.00     | Healthy               |
        | 0x07      | Temp BMC         | 28.00     | Healthy               |
        | 0x08      | Temp CPU 1       | 0.00      | Healthy               |
        | 0x09      | Temp CPU 2       | 0.00      | Healthy               |
        Payload Specific Health Status (for Nodes with more than 1 payload/mmc):
            Payload 1: Healthy
            Payload 2: Healthy

Hotswap Status: Active
Product name: 4005
Part number: T4005CXXX_2-CXX
Serial number: 9013144606
Manufacturing date: Mon Sep 19 16:35:00 2016
Type: Node
Model: MSP8022
HPM versions:
	BMC: 2.21.0940E3AB
	FPGA: 3.0.00000000
	BIOS: 2.21.093A2A53
Management Network:
        Management MAC: 00:a0:a5:8d:62:9a
        IP Source: dhcp
        IP: 10.24.22.106
        Subnet: 255.255.255.0
        Gateway: 10.24.22.3
        VLAN: 4093
Payload IPs :
	Network Interfaces:
		Id: 1, 
		Backplane: Base2, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:8d:62:96
		IP Source: static


		Id: 2, 
		Backplane: Fabric1, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:8d:62:97
		IP Source: static


	Network Interfaces:
		Id: 1, 
		Backplane: Base1, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:8d:62:98
		IP Source: static


		Id: 2, 
		Backplane: Fabric2, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:8d:62:99
		IP Source: static

================================

================================
SLOT #3
================================
Name: Node 3
Health: Healthy
Health Details: 
        Node BMC sensors aggregated for Health Status:
        | Sensor ID | Sensor Name      | Value     | Health                |
         ------------------------------------------------------------------ 
        | 0x0e      | Vcc +12.0V SUS   | 12.06     | Healthy               |
        | 0x0f      | Vcc +3.3V SUS    | 3.34      | Healthy               |
        | 0x10      | Vcc +1.5V SUS    | 1.51      | Healthy               |
        | 0x11      | Vcc +1.2V SUS    | 1.19      | Healthy               |
        | 0x04      | Temp Brd Inlet   | 24.00     | Healthy               |
        | 0x05      | Temp Brd Outlet  | 25.00     | Healthy               |
        | 0x07      | Temp BMC         | 28.00     | Healthy               |
        | 0x08      | Temp CPU 1       | 0.00      | Healthy               |
        | 0x09      | Temp CPU 2       | 0.00      | Healthy               |
        Payload Specific Health Status (for Nodes with more than 1 payload/mmc):
            Payload 1: Healthy
            Payload 2: Healthy

Hotswap Status: Active
Product name: 4005
Part number: T4005CXXX_2-CXX
Serial number: 9013144807
Manufacturing date: Mon Sep 19 17:24:00 2016
Type: Node
Model: MSP8022
HPM versions:
	BMC: 2.21.0940E3AB
	FPGA: 3.0.00000000
	BIOS: 2.21.093A2A53
Management Network:
        Management MAC: 00:a0:a5:91:aa:fe
        IP Source: dhcp
        IP: 10.24.22.125
        Subnet: 255.255.255.0
        Gateway: 10.24.22.3
        VLAN: 4093
Payload IPs :
	Network Interfaces:
		Id: 1, 
		Backplane: Base2, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:91:aa:fa
		IP Source: static


		Id: 2, 
		Backplane: Fabric1, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:91:aa:fb
		IP Source: static


	Network Interfaces:
		Id: 1, 
		Backplane: Base1, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:91:aa:fc
		IP Source: static


		Id: 2, 
		Backplane: Fabric2, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:91:aa:fd
		IP Source: static

================================

================================
SLOT #4
================================
Name: Node 4
Health: Healthy
Health Details: 
        Node BMC sensors aggregated for Health Status:
        | Sensor ID | Sensor Name      | Value     | Health                |
         ------------------------------------------------------------------ 
        | 0x0e      | Vcc +12.0V SUS   | 12.18     | Healthy               |
        | 0x0f      | Vcc +3.3V SUS    | 3.35      | Healthy               |
        | 0x10      | Vcc +1.5V SUS    | 1.50      | Healthy               |
        | 0x11      | Vcc +1.2V SUS    | 1.21      | Healthy               |
        | 0x04      | Temp Brd Inlet   | 25.00     | Healthy               |
        | 0x05      | Temp Brd Outlet  | 29.00     | Healthy               |
        | 0x07      | Temp BMC         | 30.00     | Healthy               |
        | 0x08      | Temp CPU 1       | 0.00      | Healthy               |
        | 0x09      | Temp CPU 2       | 0.00      | Healthy               |
        Payload Specific Health Status (for Nodes with more than 1 payload/mmc):
            Payload 1: Healthy
            Payload 2: Healthy

Hotswap Status: Active
Product name: 4005
Part number: T4005CXXX_2-CXX
Serial number: 9013144349
Manufacturing date: Mon Sep 19 17:19:00 2016
Type: Node
Model: MSP8022
HPM versions:
	BMC: 2.21.0940E3AB
	FPGA: 3.0.00000000
	BIOS: 2.21.093A2A53
Management Network:
        Management MAC: 00:a0:a5:91:a5:e8
        IP Source: dhcp
        IP: 10.24.22.96
        Subnet: 255.255.255.0
        Gateway: 10.24.22.3
        VLAN: 4093
Payload IPs :
	Network Interfaces:
		Id: 1, 
		Backplane: Base2, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:91:a5:e4
		IP Source: static


		Id: 2, 
		Backplane: Fabric1, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:91:a5:e5
		IP Source: static


	Network Interfaces:
		Id: 1, 
		Backplane: Base1, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:91:a5:e6
		IP Source: static


		Id: 2, 
		Backplane: Fabric2, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:91:a5:e7
		IP Source: static

================================

================================
SLOT #5
================================
Name: Node 5
Health: Healthy
Health Details: 
        Node BMC sensors aggregated for Health Status:
        | Sensor ID | Sensor Name      | Value     | Health                |
         ------------------------------------------------------------------ 
        | 0x0e      | Vcc +12.0V SUS   | 12.18     | Healthy               |
        | 0x0f      | Vcc +3.3V SUS    | 3.34      | Healthy               |
        | 0x10      | Vcc +1.5V SUS    | 1.50      | Healthy               |
        | 0x11      | Vcc +1.2V SUS    | 1.21      | Healthy               |
        | 0x04      | Temp Brd Inlet   | 24.00     | Healthy               |
        | 0x05      | Temp Brd Outlet  | 26.00     | Healthy               |
        | 0x07      | Temp BMC         | 28.00     | Healthy               |
        | 0x08      | Temp CPU 1       | 0.00      | Healthy               |
        | 0x09      | Temp CPU 2       | 0.00      | Healthy               |
        Payload Specific Health Status (for Nodes with more than 1 payload/mmc):
            Payload 1: Healthy
            Payload 2: Healthy

Hotswap Status: Active
Product name: 4005
Part number: T4005CXXX_2-CXX
Serial number: 9013144447
Manufacturing date: Mon Sep 19 16:35:00 2016
Type: Node
Model: MSP8022
HPM versions:
	BMC: 2.21.0940E3AB
	FPGA: 3.0.00000000
	BIOS: 2.21.093A2A53
Management Network:
        Management MAC: 00:a0:a5:91:a9:94
        IP Source: dhcp
        IP: 10.24.22.118
        Subnet: 255.255.255.0
        Gateway: 10.24.22.3
        VLAN: 4093
Payload IPs :
	Network Interfaces:
		Id: 1, 
		Backplane: Base2, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:91:a9:90
		IP Source: static


		Id: 2, 
		Backplane: Fabric1, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:91:a9:91
		IP Source: static


	Network Interfaces:
		Id: 1, 
		Backplane: Base1, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:91:a9:92
		IP Source: static


		Id: 2, 
		Backplane: Fabric2, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:91:a9:93
		IP Source: static

================================

================================
SLOT #6
================================
Name: Node 6
Health: Healthy
Health Details: 
        Node BMC sensors aggregated for Health Status:
        | Sensor ID | Sensor Name      | Value     | Health                |
         ------------------------------------------------------------------ 
        | 0x0e      | Vcc +12.0V SUS   | 12.18     | Healthy               |
        | 0x0f      | Vcc +3.3V SUS    | 3.35      | Healthy               |
        | 0x10      | Vcc +1.5V SUS    | 1.50      | Healthy               |
        | 0x11      | Vcc +1.2V SUS    | 1.21      | Healthy               |
        | 0x04      | Temp Brd Inlet   | 24.00     | Healthy               |
        | 0x05      | Temp Brd Outlet  | 26.00     | Healthy               |
        | 0x07      | Temp BMC         | 28.00     | Healthy               |
        | 0x08      | Temp CPU 1       | 0.00      | Healthy               |
        | 0x09      | Temp CPU 2       | 0.00      | Healthy               |
        Payload Specific Health Status (for Nodes with more than 1 payload/mmc):
            Payload 1: Healthy
            Payload 2: Healthy

Hotswap Status: Active
Product name: 4005
Part number: T4005CXXX_2-CXX
Serial number: 9013144319
Manufacturing date: Mon Sep 19 16:38:00 2016
Type: Node
Model: MSP8022
HPM versions:
	BMC: 2.21.0940E3AB
	FPGA: 3.0.00000000
	BIOS: 2.21.093A2A53
Management Network:
        Management MAC: 00:a0:a5:8d:56:fc
        IP Source: dhcp
        IP: 10.24.22.110
        Subnet: 255.255.255.0
        Gateway: 10.24.22.3
        VLAN: 4093
Payload IPs :
	Network Interfaces:
		Id: 1, 
		Backplane: Base2, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:8d:56:f8
		IP Source: static


		Id: 2, 
		Backplane: Fabric1, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:8d:56:f9
		IP Source: static


	Network Interfaces:
		Id: 1, 
		Backplane: Base1, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:8d:56:fa
		IP Source: static


		Id: 2, 
		Backplane: Fabric2, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:8d:56:fb
		IP Source: static

================================

================================
SLOT #7
================================
Name: Node 7
Health: Healthy
Health Details: 
        Node BMC sensors aggregated for Health Status:
        | Sensor ID | Sensor Name      | Value     | Health                |
         ------------------------------------------------------------------ 
        | 0x0e      | Vcc +12.0V SUS   | 12.18     | Healthy               |
        | 0x0f      | Vcc +3.3V SUS    | 3.35      | Healthy               |
        | 0x10      | Vcc +1.5V SUS    | 1.51      | Healthy               |
        | 0x11      | Vcc +1.2V SUS    | 1.21      | Healthy               |
        | 0x04      | Temp Brd Inlet   | 24.00     | Healthy               |
        | 0x05      | Temp Brd Outlet  | 27.00     | Healthy               |
        | 0x07      | Temp BMC         | 29.00     | Healthy               |
        | 0x08      | Temp CPU 1       | 0.00      | Healthy               |
        | 0x09      | Temp CPU 2       | 0.00      | Healthy               |
        Payload Specific Health Status (for Nodes with more than 1 payload/mmc):
            Payload 1: Healthy
            Payload 2: Healthy

Hotswap Status: Active
Product name: 4005
Part number: T4005CXXX_2-CXX
Serial number: 9013144427
Manufacturing date: Mon Sep 19 17:19:00 2016
Type: Node
Model: MSP8022
HPM versions:
	BMC: 2.21.0940E3AB
	FPGA: 3.0.00000000
	BIOS: 2.21.093A2A53
Management Network:
        Management MAC: 00:a0:a5:91:a8:70
        IP Source: dhcp
        IP: 10.24.22.139
        Subnet: 255.255.255.0
        Gateway: 10.24.22.3
        VLAN: 4093
Payload IPs :
	Network Interfaces:
		Id: 1, 
		Backplane: Base2, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:91:a8:6c
		IP Source: static


		Id: 2, 
		Backplane: Fabric1, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:91:a8:6d
		IP Source: static


	Network Interfaces:
		Id: 1, 
		Backplane: Base1, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:91:a8:6e
		IP Source: static


		Id: 2, 
		Backplane: Fabric2, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:91:a8:6f
		IP Source: static

================================

================================
SLOT #8
================================
Name: Node 8
Health: Healthy
Health Details: 
        Node BMC sensors aggregated for Health Status:
        | Sensor ID | Sensor Name      | Value     | Health                |
         ------------------------------------------------------------------ 
        | 0x0e      | Vcc +12.0V SUS   | 12.06     | Healthy               |
        | 0x0f      | Vcc +3.3V SUS    | 3.35      | Healthy               |
        | 0x10      | Vcc +1.5V SUS    | 1.50      | Healthy               |
        | 0x11      | Vcc +1.2V SUS    | 1.21      | Healthy               |
        | 0x04      | Temp Brd Inlet   | 24.00     | Healthy               |
        | 0x05      | Temp Brd Outlet  | 28.00     | Healthy               |
        | 0x07      | Temp BMC         | 29.00     | Healthy               |
        | 0x08      | Temp CPU 1       | 0.00      | Healthy               |
        | 0x09      | Temp CPU 2       | 0.00      | Healthy               |
        Payload Specific Health Status (for Nodes with more than 1 payload/mmc):
            Payload 1: Healthy
            Payload 2: Healthy

Hotswap Status: Inactive
Product name: 4005
Part number: T4005CXXX_2-CXX
Serial number: 9017048947
Manufacturing date: Thu Jun 11 14:40:00 2020
Type: Node
Model: MSP8022
HPM versions:
	BMC: 2.21.0940E3AB
	FPGA: 3.0.00000000
	BIOS: 2.21.093A2A53
Management Network:
        Management MAC: 00:a0:a5:dc:3b:14
        IP Source: dhcp
        IP: 10.24.22.74
        Subnet: 255.255.255.0
        Gateway: 10.24.22.3
        VLAN: 4093
Payload IPs :
	Network Interfaces:
		Id: 1, 
		Backplane: Base2, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:dc:3b:10
		IP Source: static


		Id: 2, 
		Backplane: Fabric1, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:dc:3b:11
		IP Source: static


	Network Interfaces:
		Id: 1, 
		Backplane: Base1, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:dc:3b:12
		IP Source: static


		Id: 2, 
		Backplane: Fabric2, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:dc:3b:13
		IP Source: static

================================

================================
SLOT #9
================================
Name: Node 9
Health: Healthy
Health Details: 
        Node BMC sensors aggregated for Health Status:
        | Sensor ID | Sensor Name      | Value     | Health                |
         ------------------------------------------------------------------ 
        | 0x0e      | Vcc +12.0V SUS   | 12.18     | Healthy               |
        | 0x0f      | Vcc +3.3V SUS    | 3.35      | Healthy               |
        | 0x10      | Vcc +1.5V SUS    | 1.51      | Healthy               |
        | 0x11      | Vcc +1.2V SUS    | 1.19      | Healthy               |
        | 0x04      | Temp Brd Inlet   | 24.00     | Healthy               |
        | 0x05      | Temp Brd Outlet  | 27.00     | Healthy               |
        | 0x07      | Temp BMC         | 28.00     | Healthy               |
        | 0x08      | Temp CPU 1       | 0.00      | Healthy               |
        | 0x09      | Temp CPU 2       | 0.00      | Healthy               |
        Payload Specific Health Status (for Nodes with more than 1 payload/mmc):
            Payload 1: Healthy
            Payload 2: Healthy

Hotswap Status: Active
Product name: 4005
Part number: T4005CXXX_2-CXX
Serial number: 9013144448
Manufacturing date: Mon Sep 19 16:49:00 2016
Type: Node
Model: MSP8022
HPM versions:
	BMC: 2.21.0940E3AB
	FPGA: 3.0.00000000
	BIOS: 2.21.093A2A53
Management Network:
        Management MAC: 00:a0:a5:8d:61:e4
        IP Source: dhcp
        IP: 10.24.22.95
        Subnet: 255.255.255.0
        Gateway: 10.24.22.3
        VLAN: 4093
Payload IPs :
	Network Interfaces:
		Id: 1, 
		Backplane: Base2, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:8d:61:e0
		IP Source: static


		Id: 2, 
		Backplane: Fabric1, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:8d:61:e1
		IP Source: static


	Network Interfaces:
		Id: 1, 
		Backplane: Base1, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:8d:61:e2
		IP Source: static


		Id: 2, 
		Backplane: Fabric2, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:8d:61:e3
		IP Source: static

================================

*******************************
Original JSON string
*******************************
{ "name": "Platform #1", "number": "1", "chassis": "ms2900", "health": "Green", "fans":[ {"number": "1", "name": "Fan 1", "type": "fan", "health": "Green", "rpm": "3080","alarm": {"alarmlevel": "None"}, "LedIdentify": {"status": "off"}, "hotswapStatus":{"state": "M4", "text": "Active"}}, {"number": "2", "name": "Fan 2", "type": "fan", "health": "Green", "rpm": "3080","alarm": {"alarmlevel": "None"}, "LedIdentify": {"status": "off"}, "hotswapStatus":{"state": "M4", "text": "Active"}}, {"number": "3", "name": "Fan 3", "type": "fan", "health": "Green", "rpm": "3157","alarm": {"alarmlevel": "None"}, "LedIdentify": {"status": "off"}, "hotswapStatus":{"state": "M4", "text": "Active"}}, {"number": "4", "name": "Fan 4", "type": "fan", "health": "Green", "rpm": "3157","alarm": {"alarmlevel": "None"}, "LedIdentify": {"status": "off"}, "hotswapStatus":{"state": "M4", "text": "Active"}}, {"number": "5", "name": "Fan 5", "type": "fan", "health": "Green", "rpm": "3157","alarm": {"alarmlevel": "None"}, "LedIdentify": {"status": "off"}, "hotswapStatus":{"state": "M4", "text": "Active"}} ], "type": "platform", "components": [{"number": "10", "name": "HubNode 1", "health": "Green", "fruInfo": {"mfgDate": "Fri Sep 23 14:49:00 2016", "boardMfg": "Kontron", "boardProductName": "MSH8900", "boardProductPart": "T4301X_2-X", "boardSerialNumber": "9013133745"},"hotswapStatus":{"state": "M4", "text": "Active"},"type":"hubnode", "HubNodeFeatures":{"SwitchSpeedSupport": "1", "PortModeSupport": "0"}, "versions" : [{ "name" : "BMC", "major" : "3", "minor" : "20", "revision" : "093AA546"},{ "name" : "FPGA", "major" : "2", "minor" : "06", "revision" : "00000000"}],"model": "MSH8900", "isUpdating" : "0", "managementIP": "10.24.22.104", "managementMAC": "00:a0:a5:8a:8d:c7", "alarm": {"alarmlevel": "None", "sensors":[]}, "LedIdentify": {"status": "off"}, "components": [{ "description": "Switch 1", "number": "1", "hotswapStatus":{"state": "M4", "text": "Active"}, "health": "Green", "networkInterfaces": [{ "id": "1", "backplane": "Management", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:8a:8d:a8"}]}], "status": "Standby"}, {"number": "11", "name": "HubNode 2", "health": "Green", "fruInfo": {"mfgDate": "Fri Sep 23 14:46:00 2016", "boardMfg": "Kontron", "boardProductName": "MSH8900", "boardProductPart": "T4301X_2-X", "boardSerialNumber": "9013133588"},"hotswapStatus":{"state": "M4", "text": "Active"},"type":"hubnode", "HubNodeFeatures":{"SwitchSpeedSupport": "1", "PortModeSupport": "0"}, "versions" : [{ "name" : "BMC", "major" : "3", "minor" : "20", "revision" : "093AA546"},{ "name" : "FPGA", "major" : "2", "minor" : "06", "revision" : "00000000"}],"model": "MSH8900", "isUpdating" : "0", "managementIP": "10.24.22.132", "managementMAC": "00:a0:a5:91:40:25", "alarm": {"alarmlevel": "None", "sensors":[]}, "LedIdentify": {"status": "off"}, "components": [{ "description": "Switch 2", "number": "1", "hotswapStatus":{"state": "M4", "text": "Active"}, "health": "Green", "networkInterfaces": [{ "id": "1", "backplane": "Management", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:91:40:06"}]}], "status": "Active"}, {"number": "1", "name": "Node 1", "health": "Green", "fruInfo": {"mfgDate": "Mon Sep 19 13:09:00 2016", "boardMfg": "Kontron", "boardProductName": "4005", "boardProductPart": "T4005CXXX_2-CXX", "boardSerialNumber": "9013144358"},"hotswapStatus":{"state": "M4", "text": "Active"},"type":"node", "versions" : [{ "name" : "BMC", "major" : "2", "minor" : "21", "revision" : "0940E3AB"},{ "name" : "FPGA", "major" : "3", "minor" : "00", "revision" : "00000000"},{ "name" : "BIOS", "major" : "2", "minor" : "21", "revision" : "093A2A53"}],"model": "MSP8022", "isUpdating" : "0", "managementIP": "10.24.22.148", "managementMAC": "00:a0:a5:8c:e6:22", "alarm": {"alarmlevel": "None", "sensors":[]}, "LedIdentify": {"status": "off"}, "components": [{ "description": "Payload1       ", "number": "1", "hotswapStatus":{"state": "M1", "text": "Inactive"}, "health": "Green", "networkInterfaces": [{ "id": "1", "backplane": "Base2", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:8c:e6:1e"}, { "id": "2", "backplane": "Fabric1", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:8c:e6:1f"}]}, { "description": "Payload2       ", "number": "2", "hotswapStatus":{"state": "M1", "text": "Inactive"}, "health": "Green", "networkInterfaces": [{ "id": "1", "backplane": "Base1", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:8c:e6:20"}, { "id": "2", "backplane": "Fabric2", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:8c:e6:21"}]}] }, {"number": "2", "name": "Node 2", "health": "Green", "fruInfo": {"mfgDate": "Mon Sep 19 16:35:00 2016", "boardMfg": "Kontron", "boardProductName": "4005", "boardProductPart": "T4005CXXX_2-CXX", "boardSerialNumber": "9013144606"},"hotswapStatus":{"state": "M4", "text": "Active"},"type":"node", "versions" : [{ "name" : "BMC", "major" : "2", "minor" : "21", "revision" : "0940E3AB"},{ "name" : "FPGA", "major" : "3", "minor" : "00", "revision" : "00000000"},{ "name" : "BIOS", "major" : "2", "minor" : "21", "revision" : "093A2A53"}],"model": "MSP8022", "isUpdating" : "0", "managementIP": "10.24.22.106", "managementMAC": "00:a0:a5:8d:62:9a", "alarm": {"alarmlevel": "None", "sensors":[]}, "LedIdentify": {"status": "off"}, "components": [{ "description": "Payload1       ", "number": "1", "hotswapStatus":{"state": "M1", "text": "Inactive"}, "health": "Green", "networkInterfaces": [{ "id": "1", "backplane": "Base2", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:8d:62:96"}, { "id": "2", "backplane": "Fabric1", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:8d:62:97"}]}, { "description": "Payload2       ", "number": "2", "hotswapStatus":{"state": "M1", "text": "Inactive"}, "health": "Green", "networkInterfaces": [{ "id": "1", "backplane": "Base1", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:8d:62:98"}, { "id": "2", "backplane": "Fabric2", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:8d:62:99"}]}] }, {"number": "3", "name": "Node 3", "health": "Green", "fruInfo": {"mfgDate": "Mon Sep 19 17:24:00 2016", "boardMfg": "Kontron", "boardProductName": "4005", "boardProductPart": "T4005CXXX_2-CXX", "boardSerialNumber": "9013144807"},"hotswapStatus":{"state": "M4", "text": "Active"},"type":"node", "versions" : [{ "name" : "BMC", "major" : "2", "minor" : "21", "revision" : "0940E3AB"},{ "name" : "FPGA", "major" : "3", "minor" : "00", "revision" : "00000000"},{ "name" : "BIOS", "major" : "2", "minor" : "21", "revision" : "093A2A53"}],"model": "MSP8022", "isUpdating" : "0", "managementIP": "10.24.22.125", "managementMAC": "00:a0:a5:91:aa:fe", "alarm": {"alarmlevel": "None", "sensors":[]}, "LedIdentify": {"status": "off"}, "components": [{ "description": "Payload1       ", "number": "1", "hotswapStatus":{"state": "M1", "text": "Inactive"}, "health": "Green", "networkInterfaces": [{ "id": "1", "backplane": "Base2", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:91:aa:fa"}, { "id": "2", "backplane": "Fabric1", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:91:aa:fb"}]}, { "description": "Payload2       ", "number": "2", "hotswapStatus":{"state": "M1", "text": "Inactive"}, "health": "Green", "networkInterfaces": [{ "id": "1", "backplane": "Base1", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:91:aa:fc"}, { "id": "2", "backplane": "Fabric2", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:91:aa:fd"}]}] }, {"number": "4", "name": "Node 4", "health": "Green", "fruInfo": {"mfgDate": "Mon Sep 19 17:19:00 2016", "boardMfg": "Kontron", "boardProductName": "4005", "boardProductPart": "T4005CXXX_2-CXX", "boardSerialNumber": "9013144349"},"hotswapStatus":{"state": "M4", "text": "Active"},"type":"node", "versions" : [{ "name" : "BMC", "major" : "2", "minor" : "21", "revision" : "0940E3AB"},{ "name" : "FPGA", "major" : "3", "minor" : "00", "revision" : "00000000"},{ "name" : "BIOS", "major" : "2", "minor" : "21", "revision" : "093A2A53"}],"model": "MSP8022", "isUpdating" : "0", "managementIP": "10.24.22.96", "managementMAC": "00:a0:a5:91:a5:e8", "alarm": {"alarmlevel": "None", "sensors":[]}, "LedIdentify": {"status": "off"}, "components": [{ "description": "Payload1       ", "number": "1", "hotswapStatus":{"state": "M1", "text": "Inactive"}, "health": "Green", "networkInterfaces": [{ "id": "1", "backplane": "Base2", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:91:a5:e4"}, { "id": "2", "backplane": "Fabric1", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:91:a5:e5"}]}, { "description": "Payload2       ", "number": "2", "hotswapStatus":{"state": "M1", "text": "Inactive"}, "health": "Green", "networkInterfaces": [{ "id": "1", "backplane": "Base1", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:91:a5:e6"}, { "id": "2", "backplane": "Fabric2", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:91:a5:e7"}]}] }, {"number": "5", "name": "Node 5", "health": "Green", "fruInfo": {"mfgDate": "Mon Sep 19 16:35:00 2016", "boardMfg": "Kontron", "boardProductName": "4005", "boardProductPart": "T4005CXXX_2-CXX", "boardSerialNumber": "9013144447"},"hotswapStatus":{"state": "M4", "text": "Active"},"type":"node", "versions" : [{ "name" : "BMC", "major" : "2", "minor" : "21", "revision" : "0940E3AB"},{ "name" : "FPGA", "major" : "3", "minor" : "00", "revision" : "00000000"},{ "name" : "BIOS", "major" : "2", "minor" : "21", "revision" : "093A2A53"}],"model": "MSP8022", "isUpdating" : "0", "managementIP": "10.24.22.118", "managementMAC": "00:a0:a5:91:a9:94", "alarm": {"alarmlevel": "None", "sensors":[]}, "LedIdentify": {"status": "off"}, "components": [{ "description": "Payload1       ", "number": "1", "hotswapStatus":{"state": "M1", "text": "Inactive"}, "health": "Green", "networkInterfaces": [{ "id": "1", "backplane": "Base2", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:91:a9:90"}, { "id": "2", "backplane": "Fabric1", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:91:a9:91"}]}, { "description": "Payload2       ", "number": "2", "hotswapStatus":{"state": "M1", "text": "Inactive"}, "health": "Green", "networkInterfaces": [{ "id": "1", "backplane": "Base1", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:91:a9:92"}, { "id": "2", "backplane": "Fabric2", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:91:a9:93"}]}] }, {"number": "6", "name": "Node 6", "health": "Green", "fruInfo": {"mfgDate": "Mon Sep 19 16:38:00 2016", "boardMfg": "Kontron", "boardProductName": "4005", "boardProductPart": "T4005CXXX_2-CXX", "boardSerialNumber": "9013144319"},"hotswapStatus":{"state": "M4", "text": "Active"},"type":"node", "versions" : [{ "name" : "BMC", "major" : "2", "minor" : "21", "revision" : "0940E3AB"},{ "name" : "FPGA", "major" : "3", "minor" : "00", "revision" : "00000000"},{ "name" : "BIOS", "major" : "2", "minor" : "21", "revision" : "093A2A53"}],"model": "MSP8022", "isUpdating" : "0", "managementIP": "10.24.22.110", "managementMAC": "00:a0:a5:8d:56:fc", "alarm": {"alarmlevel": "None", "sensors":[]}, "LedIdentify": {"status": "off"}, "components": [{ "description": "Payload1       ", "number": "1", "hotswapStatus":{"state": "M1", "text": "Inactive"}, "health": "Green", "networkInterfaces": [{ "id": "1", "backplane": "Base2", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:8d:56:f8"}, { "id": "2", "backplane": "Fabric1", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:8d:56:f9"}]}, { "description": "Payload2       ", "number": "2", "hotswapStatus":{"state": "M1", "text": "Inactive"}, "health": "Green", "networkInterfaces": [{ "id": "1", "backplane": "Base1", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:8d:56:fa"}, { "id": "2", "backplane": "Fabric2", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:8d:56:fb"}]}] }, {"number": "7", "name": "Node 7", "health": "Green", "fruInfo": {"mfgDate": "Mon Sep 19 17:19:00 2016", "boardMfg": "Kontron", "boardProductName": "4005", "boardProductPart": "T4005CXXX_2-CXX", "boardSerialNumber": "9013144427"},"hotswapStatus":{"state": "M4", "text": "Active"},"type":"node", "versions" : [{ "name" : "BMC", "major" : "2", "minor" : "21", "revision" : "0940E3AB"},{ "name" : "FPGA", "major" : "3", "minor" : "00", "revision" : "00000000"},{ "name" : "BIOS", "major" : "2", "minor" : "21", "revision" : "093A2A53"}],"model": "MSP8022", "isUpdating" : "0", "managementIP": "10.24.22.139", "managementMAC": "00:a0:a5:91:a8:70", "alarm": {"alarmlevel": "None", "sensors":[]}, "LedIdentify": {"status": "off"}, "components": [{ "description": "Payload1       ", "number": "1", "hotswapStatus":{"state": "M1", "text": "Inactive"}, "health": "Green", "networkInterfaces": [{ "id": "1", "backplane": "Base2", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:91:a8:6c"}, { "id": "2", "backplane": "Fabric1", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:91:a8:6d"}]}, { "description": "Payload2       ", "number": "2", "hotswapStatus":{"state": "M1", "text": "Inactive"}, "health": "Green", "networkInterfaces": [{ "id": "1", "backplane": "Base1", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:91:a8:6e"}, { "id": "2", "backplane": "Fabric2", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:91:a8:6f"}]}] }, {"number": "8", "name": "Node 8", "health": "Green", "fruInfo": {"mfgDate": "Thu Jun 11 14:40:00 2020", "boardMfg": "Kontron", "boardProductName": "4005", "boardProductPart": "T4005CXXX_2-CXX", "boardSerialNumber": "9017048947"},"hotswapStatus":{"state": "M1", "text": "Inactive"},"type":"node", "versions" : [{ "name" : "BMC", "major" : "2", "minor" : "21", "revision" : "0940E3AB"},{ "name" : "FPGA", "major" : "3", "minor" : "00", "revision" : "00000000"},{ "name" : "BIOS", "major" : "2", "minor" : "21", "revision" : "093A2A53"}],"model": "MSP8022", "isUpdating" : "0", "managementIP": "10.24.22.74", "managementMAC": "00:a0:a5:dc:3b:14", "alarm": {"alarmlevel": "None", "sensors":[]}, "LedIdentify": {"status": "off"}, "components": [{ "description": "Payload1       ", "number": "1", "hotswapStatus":{"state": "M1", "text": "Inactive"}, "health": "Green", "networkInterfaces": [{ "id": "1", "backplane": "Base2", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:dc:3b:10"}, { "id": "2", "backplane": "Fabric1", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:dc:3b:11"}]}, { "description": "Payload2       ", "number": "2", "hotswapStatus":{"state": "M1", "text": "Inactive"}, "health": "Green", "networkInterfaces": [{ "id": "1", "backplane": "Base1", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:dc:3b:12"}, { "id": "2", "backplane": "Fabric2", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:dc:3b:13"}]}] }, {"number": "9", "name": "Node 9", "health": "Green", "fruInfo": {"mfgDate": "Mon Sep 19 16:49:00 2016", "boardMfg": "Kontron", "boardProductName": "4005", "boardProductPart": "T4005CXXX_2-CXX", "boardSerialNumber": "9013144448"},"hotswapStatus":{"state": "M4", "text": "Active"},"type":"node", "versions" : [{ "name" : "BMC", "major" : "2", "minor" : "21", "revision" : "0940E3AB"},{ "name" : "FPGA", "major" : "3", "minor" : "00", "revision" : "00000000"},{ "name" : "BIOS", "major" : "2", "minor" : "21", "revision" : "093A2A53"}],"model": "MSP8022", "isUpdating" : "0", "managementIP": "10.24.22.95", "managementMAC": "00:a0:a5:8d:61:e4", "alarm": {"alarmlevel": "None", "sensors":[]}, "LedIdentify": {"status": "off"}, "components": [{ "description": "Payload1       ", "number": "1", "hotswapStatus":{"state": "M1", "text": "Inactive"}, "health": "Green", "networkInterfaces": [{ "id": "1", "backplane": "Base2", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:8d:61:e0"}, { "id": "2", "backplane": "Fabric1", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:8d:61:e1"}]}, { "description": "Payload2       ", "number": "2", "hotswapStatus":{"state": "M1", "text": "Inactive"}, "health": "Green", "networkInterfaces": [{ "id": "1", "backplane": "Base1", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:8d:61:e2"}, { "id": "2", "backplane": "Fabric2", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:8d:61:e3"}]}] }, { "name": "PSU", "components": [{"id": "PSU1", "number": "1", "name": "Power Supply 1", "health": "Green", "type": "psu", "hotswapStatus":{"state": "M4", "text": "Active"},"alarm": {"alarmlevel": "None"}, "tempInlet": "24.00", "tempOutlet": "31.00", "vIn": "205.00", "powerOut": "40", "powerScale": "1400","peakConsumption": "328", "averageConsumption": "132"},{"id": "PSU2", "number": "2", "name": "Power Supply 2", "health": "Green", "type": "psu", "hotswapStatus":{"state": "M4", "text": "Active"},"alarm": {"alarmlevel": "None"}, "tempInlet": "24.00", "tempOutlet": "31.00", "vIn": "206.00", "powerOut": "40", "powerScale": "1400","peakConsumption": "328", "averageConsumption": "133"}]}], "switchOID": {"oid": "1.3.6.1.4.1.6603"}, "alarm": {"alarmlevel": "None",  "components" : [ {"nodes" : [] } , {"psu" : [] }, {"fans" : [] }], "text": ""}, "LedIdentify": {"status": "off"}}