*******************************
System informations
*******************************
Name: SYMKLOUD
chassis: ms2900
Health: Healthy
*******************************
Fans: 
*******************************
Fan 1: 
	Present :true
	Status :Healthy
	3080 RPM
Fan 2: 
	Present :true
	Status :Healthy
	3080 RPM
Fan 3: 
	Present :true
	Status :Healthy
	3157 RPM
Fan 4: 
	Present :true
	Status :Healthy
	3157 RPM
Fan 5: 
	Present :true
	Status :Healthy
	3080 RPM


*******************************
PSU: 
*******************************
Name: PSU 1
Health: Healthy
Health Details: No details available
Hotswap Status: Active
FRU: Informations are invalid

Name: PSU 2
Health: Healthy
Health Details: No details available
Hotswap Status: Active
FRU: Informations are invalid



*******************************
HubNodes
*******************************

================================
Name: HubNode 1
Health: Healthy
Health Details: 
        | Sensor ID | Sensor Name      | Value   | Health                |
         ---------------------------------------------------------------- 
        | 0x0b      | Temp On-Board    | 35.00   | Healthy               |
        | 0x0c      | Temp Eth Switch  | 35.00   | Healthy               |
        | 0x0d      | Temp Quad Phy    | 42.00   | Healthy               |
        | 0x0e      | Temp Inlet       | 25.00   | Healthy               |
        | 0x0f      | Temp Phy 10G     | 57.00   | Healthy               |
        | 0x10      | Vcc +12V In      | 12.18   | Healthy               |
        | 0x11      | Vcc +5V SUS      | 5.05    | Healthy               |
        | 0x12      | Vcc +3.3V SUS    | 3.31    | Healthy               |
        | 0x13      | Vcc +1.8V SUS    | 1.79    | Healthy               |
        | 0x14      | Vcc +1.5V SUS    | 1.51    | Healthy               |
        | 0x15      | Vcc +1.25V SUS   | 1.24    | Healthy               |
        | 0x16      | Vcc +1.2V SUS    | 1.19    | Healthy               |
        | 0x17      | Vcc +0.75V SUS   | 0.75    | Healthy               |
        | 0x18      | Vcc +3.3V        | 3.31    | Healthy               |
        | 0x19      | Vcc +2.5V        | 2.49    | Healthy               |
        | 0x1a      | Vcc +1.8V        | 1.78    | Healthy               |
        | 0x1b      | Vcc +1.2V        | 1.21    | Healthy               |
        | 0x1c      | Vcc +1.0V        | 1.01    | Healthy               |
        | 0x1d      | Vbat +3V         | 3.09    | Healthy               |
        | 0x3f      | Power Good Latch | 0x8001  | Healthy               |
        | 0x40      | FPGA RW Status   | 0x8002  | Healthy               |
        | 0x41      | FPGA Heartbeat   | 0x8002  | Healthy               |
        | 0x48      | ShMC Redun State | 0x8002  | Healthy               |
Hotswap Status: Active
Product name: MSH8900
Part number: T4301X_2-X
Serial number: 9013133544
Manufacturing date: Thu Jun 23 12:55:00 2016
Type: HubNode
Status: Active
Model: MSH8900
HPM versions:
	BMC: 3.18.093413FB
	FPGA: 2.4.00000000
Management Network:
        Management MAC: 00:a0:a5:8a:62:25
        IP Source: dhcp
        IP: 10.24.47.113
        Subnet: 255.255.255.0
        Gateway: 10.24.47.3
        VLAN: FFD
Payload IPs :
	Network Interfaces:
		Id: 1, 
		Backplane: Management, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:8a:62:06
		IP Source: static

================================

================================
Name: HubNode 2
Health: Healthy
Health Details: 
        | Sensor ID | Sensor Name      | Value   | Health                |
         ---------------------------------------------------------------- 
        | 0x0b      | Temp On-Board    | 34.00   | Healthy               |
        | 0x0c      | Temp Eth Switch  | 34.00   | Healthy               |
        | 0x0d      | Temp Quad Phy    | 42.00   | Healthy               |
        | 0x0e      | Temp Inlet       | 25.00   | Healthy               |
        | 0x0f      | Temp Phy 10G     | 57.00   | Healthy               |
        | 0x10      | Vcc +12V In      | 12.18   | Healthy               |
        | 0x11      | Vcc +5V SUS      | 5.10    | Healthy               |
        | 0x12      | Vcc +3.3V SUS    | 3.31    | Healthy               |
        | 0x13      | Vcc +1.8V SUS    | 1.79    | Healthy               |
        | 0x14      | Vcc +1.5V SUS    | 1.49    | Healthy               |
        | 0x15      | Vcc +1.25V SUS   | 1.24    | Healthy               |
        | 0x16      | Vcc +1.2V SUS    | 1.19    | Healthy               |
        | 0x17      | Vcc +0.75V SUS   | 0.74    | Healthy               |
        | 0x18      | Vcc +3.3V        | 3.31    | Healthy               |
        | 0x19      | Vcc +2.5V        | 2.48    | Healthy               |
        | 0x1a      | Vcc +1.8V        | 1.78    | Healthy               |
        | 0x1b      | Vcc +1.2V        | 1.21    | Healthy               |
        | 0x1c      | Vcc +1.0V        | 1.01    | Healthy               |
        | 0x1d      | Vbat +3V         | 3.07    | Healthy               |
        | 0x3f      | Power Good Latch | 0x8001  | Healthy               |
        | 0x40      | FPGA RW Status   | 0x8002  | Healthy               |
        | 0x41      | FPGA Heartbeat   | 0x8002  | Healthy               |
        | 0x48      | ShMC Redun State | 0x8008  | Healthy               |
Hotswap Status: Active
Product name: MSH8900
Part number: T4301X_2-X
Serial number: 9013133555
Manufacturing date: Wed Jul  6 18:47:00 2016
Type: HubNode
Status: Standby
Model: MSH8900
HPM versions:
	BMC: 3.18.093413FB
	FPGA: 2.4.00000000
Management Network:
        Management MAC: 00:a0:a5:8a:ec:69
        IP Source: dhcp
        IP: 10.24.47.86
        Subnet: 255.255.255.0
        Gateway: 10.24.47.3
        VLAN: FFD
Payload IPs :
	Network Interfaces:
		Id: 1, 
		Backplane: Management, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:8a:ec:4a
		IP Source: static

================================

*******************************
Nodes
*******************************

================================
SLOT #1
================================
Name: Node 1
Health: Healthy
Health Details: 
        | Sensor ID | Sensor Name      | Value   | Health                |
         ---------------------------------------------------------------- 
        | 0x0e      | Vcc +12.0V SUS   | 12.06   | Healthy               |
        | 0x0f      | Vcc +3.3V SUS    | 3.35    | Healthy               |
        | 0x10      | Vcc +1.5V SUS    | 1.50    | Healthy               |
        | 0x11      | Vcc +1.2V SUS    | 1.19    | Healthy               |
        | 0x04      | Temp Brd Inlet   | 25.00   | Healthy               |
        | 0x05      | Temp Brd Outlet  | 25.00   | Healthy               |
        | 0x07      | Temp BMC         | 28.00   | Healthy               |
        | 0x08      | Temp CPU 1       | 0.00    | Healthy               |
        | 0x09      | Temp CPU 2       | 0.00    | Healthy               |
Hotswap Status: Inactive
Product name: 4005
Part number: T4005CXXX_2-CXX
Serial number: 9013138867
Manufacturing date: Thu Jul 28 16:39:00 2016
Type: Node
Model: MSP8022
HPM versions:
	BMC: 2.18.08FA45E0
	FPGA: 2.C.00000000
	BIOS: 0.0.00000000
Management Network:
        Management MAC: 00:a0:a5:8a:97:3e
        IP Source: dhcp
        IP: 10.24.47.142
        Subnet: 255.255.255.0
        Gateway: 10.24.47.3
        VLAN: FFD
Payload IPs :
	Network Interfaces:
		Id: 1, 
		Backplane: Base2, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:8a:97:3a
		IP Source: static


		Id: 2, 
		Backplane: Fabric1, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:8a:97:3b
		IP Source: static


	Network Interfaces:
		Id: 1, 
		Backplane: Base1, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:8a:97:3c
		IP Source: static


		Id: 2, 
		Backplane: Fabric2, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:8a:97:3d
		IP Source: static

================================

================================
SLOT #2
================================
Name: Node 2
Health: Healthy
Health Details: 
        | Sensor ID | Sensor Name      | Value   | Health                |
         ---------------------------------------------------------------- 
        | 0x0e      | Vcc +12.0V SUS   | 12.01   | Healthy               |
        | 0x0f      | Vcc +3.3V SUS    | 3.35    | Healthy               |
        | 0x10      | Vcc +1.5V SUS    | 1.50    | Healthy               |
        | 0x11      | Vcc +1.2V SUS    | 1.19    | Healthy               |
        | 0x04      | Temp Brd Inlet   | 25.00   | Healthy               |
        | 0x05      | Temp Brd Outlet  | 26.00   | Healthy               |
        | 0x07      | Temp BMC         | 28.00   | Healthy               |
        | 0x08      | Temp CPU 1       | 0.00    | Healthy               |
        | 0x09      | Temp CPU 2       | 0.00    | Healthy               |
Hotswap Status: Inactive
Product name: 4005
Part number: T4005CXXX_2-CXX
Serial number: 9013138963
Manufacturing date: Thu Jul 28 16:42:00 2016
Type: Node
Model: MSP8022
HPM versions:
	BMC: 2.18.08FA45E0
	FPGA: 2.C.00000000
	BIOS: 0.0.00000000
Management Network:
        Management MAC: 00:a0:a5:91:4e:82
        IP Source: dhcp
        IP: 10.24.47.169
        Subnet: 255.255.255.0
        Gateway: 10.24.47.3
        VLAN: FFD
Payload IPs :
	Network Interfaces:
		Id: 1, 
		Backplane: Base2, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:91:4e:7e
		IP Source: static


		Id: 2, 
		Backplane: Fabric1, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:91:4e:7f
		IP Source: static


	Network Interfaces:
		Id: 1, 
		Backplane: Base1, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:91:4e:80
		IP Source: static


		Id: 2, 
		Backplane: Fabric2, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:91:4e:81
		IP Source: static

================================

================================
SLOT #3
================================
Name: Node 3
Health: Healthy
Health Details: 
        | Sensor ID | Sensor Name      | Value   | Health                |
         ---------------------------------------------------------------- 
        | 0x0e      | Vcc +12.0V SUS   | 12.18   | Healthy               |
        | 0x0f      | Vcc +3.3V SUS    | 3.34    | Healthy               |
        | 0x10      | Vcc +1.5V SUS    | 1.50    | Healthy               |
        | 0x11      | Vcc +1.2V SUS    | 1.21    | Healthy               |
        | 0x04      | Temp Brd Inlet   | 25.00   | Healthy               |
        | 0x05      | Temp Brd Outlet  | 26.00   | Healthy               |
        | 0x07      | Temp BMC         | 28.00   | Healthy               |
        | 0x08      | Temp CPU 1       | 0.00    | Healthy               |
        | 0x09      | Temp CPU 2       | 0.00    | Healthy               |
Hotswap Status: Inactive
Product name: 4005
Part number: T4005CXXX_2-CXX
Serial number: 9013138864
Manufacturing date: Thu Jul 28 16:43:00 2016
Type: Node
Model: MSP8022
HPM versions:
	BMC: 2.18.08FA45E0
	FPGA: 2.C.00000000
	BIOS: 0.0.00000000
Management Network:
        Management MAC: 00:a0:a5:91:4c:80
        IP Source: dhcp
        IP: 10.24.47.188
        Subnet: 255.255.255.0
        Gateway: 10.24.47.3
        VLAN: FFD
Payload IPs :
	Network Interfaces:
		Id: 1, 
		Backplane: Base2, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:91:4c:7c
		IP Source: static


		Id: 2, 
		Backplane: Fabric1, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:91:4c:7d
		IP Source: static


	Network Interfaces:
		Id: 1, 
		Backplane: Base1, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:91:4c:7e
		IP Source: static


		Id: 2, 
		Backplane: Fabric2, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:91:4c:7f
		IP Source: static

================================

================================
SLOT #4
================================
Name: Node 4
Health: Healthy
Health Details: 
        | Sensor ID | Sensor Name      | Value   | Health                |
         ---------------------------------------------------------------- 
        | 0x0e      | Vcc +12.0V SUS   | 12.18   | Healthy               |
        | 0x0f      | Vcc +3.3V SUS    | 3.34    | Healthy               |
        | 0x10      | Vcc +1.5V SUS    | 1.50    | Healthy               |
        | 0x11      | Vcc +1.2V SUS    | 1.19    | Healthy               |
        | 0x04      | Temp Brd Inlet   | 24.00   | Healthy               |
        | 0x05      | Temp Brd Outlet  | 25.00   | Healthy               |
        | 0x07      | Temp BMC         | 27.00   | Healthy               |
        | 0x08      | Temp CPU 1       | 0.00    | Healthy               |
        | 0x09      | Temp CPU 2       | 0.00    | Healthy               |
Hotswap Status: Inactive
Product name: 4005
Part number: T4005CXXX_2-CXX
Serial number: 9013138918
Manufacturing date: Thu Jul 28 15:54:00 2016
Type: Node
Model: MSP8022
HPM versions:
	BMC: 2.18.08FA45E0
	FPGA: 2.C.00000000
	BIOS: 0.0.00000000
Management Network:
        Management MAC: 00:a0:a5:91:4e:e0
        IP Source: dhcp
        IP: 10.24.47.172
        Subnet: 255.255.255.0
        Gateway: 10.24.47.3
        VLAN: FFD
Payload IPs :
	Network Interfaces:
		Id: 1, 
		Backplane: Base2, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:91:4e:dc
		IP Source: static


		Id: 2, 
		Backplane: Fabric1, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:91:4e:dd
		IP Source: static


	Network Interfaces:
		Id: 1, 
		Backplane: Base1, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:91:4e:de
		IP Source: static


		Id: 2, 
		Backplane: Fabric2, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:91:4e:df
		IP Source: static

================================

================================
SLOT #5
================================
Name: Node 5
Health: Healthy
Health Details: 
        | Sensor ID | Sensor Name      | Value   | Health                |
         ---------------------------------------------------------------- 
        | 0x0e      | Vcc +12.0V SUS   | 12.18   | Healthy               |
        | 0x0f      | Vcc +3.3V SUS    | 3.35    | Healthy               |
        | 0x10      | Vcc +1.5V SUS    | 1.50    | Healthy               |
        | 0x11      | Vcc +1.2V SUS    | 1.19    | Healthy               |
        | 0x04      | Temp Brd Inlet   | 24.00   | Healthy               |
        | 0x05      | Temp Brd Outlet  | 26.00   | Healthy               |
        | 0x07      | Temp BMC         | 28.00   | Healthy               |
        | 0x08      | Temp CPU 1       | 0.00    | Healthy               |
        | 0x09      | Temp CPU 2       | 0.00    | Healthy               |
Hotswap Status: Inactive
Product name: 4005
Part number: T4005CXXX_2-CXX
Serial number: 9013138719
Manufacturing date: Thu Jul 28 15:53:00 2016
Type: Node
Model: MSP8022
HPM versions:
	BMC: 2.18.08FA45E0
	FPGA: 2.C.00000000
	BIOS: 0.0.00000000
Management Network:
        Management MAC: 00:a0:a5:91:4f:40
        IP Source: dhcp
        IP: 10.24.47.105
        Subnet: 255.255.255.0
        Gateway: 10.24.47.3
        VLAN: FFD
Payload IPs :
	Network Interfaces:
		Id: 1, 
		Backplane: Base2, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:91:4f:3c
		IP Source: static


		Id: 2, 
		Backplane: Fabric1, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:91:4f:3d
		IP Source: static


	Network Interfaces:
		Id: 1, 
		Backplane: Base1, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:91:4f:3e
		IP Source: static


		Id: 2, 
		Backplane: Fabric2, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:91:4f:3f
		IP Source: static

================================

================================
SLOT #6
================================
Name: Node 6
Health: Healthy
Health Details: 
        | Sensor ID | Sensor Name      | Value   | Health                |
         ---------------------------------------------------------------- 
        | 0x0e      | Vcc +12.0V SUS   | 12.18   | Healthy               |
        | 0x0f      | Vcc +3.3V SUS    | 3.35    | Healthy               |
        | 0x10      | Vcc +1.5V SUS    | 1.51    | Healthy               |
        | 0x11      | Vcc +1.2V SUS    | 1.21    | Healthy               |
        | 0x04      | Temp Brd Inlet   | 24.00   | Healthy               |
        | 0x05      | Temp Brd Outlet  | 26.00   | Healthy               |
        | 0x07      | Temp BMC         | 28.00   | Healthy               |
        | 0x08      | Temp CPU 1       | 0.00    | Healthy               |
        | 0x09      | Temp CPU 2       | 0.00    | Healthy               |
Hotswap Status: Inactive
Product name: 4005
Part number: T4005CXXX_2-CXX
Serial number: 9013138877
Manufacturing date: Thu Jul 28 16:27:00 2016
Type: Node
Model: MSP8022
HPM versions:
	BMC: 2.18.08FA45E0
	FPGA: 2.C.00000000
	BIOS: 0.0.00000000
Management Network:
        Management MAC: 00:a0:a5:91:4e:d4
        IP Source: dhcp
        IP: 10.24.47.164
        Subnet: 255.255.255.0
        Gateway: 10.24.47.3
        VLAN: FFD
Payload IPs :
	Network Interfaces:
		Id: 1, 
		Backplane: Base2, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:91:4e:d0
		IP Source: static


		Id: 2, 
		Backplane: Fabric1, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:91:4e:d1
		IP Source: static


	Network Interfaces:
		Id: 1, 
		Backplane: Base1, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:91:4e:d2
		IP Source: static


		Id: 2, 
		Backplane: Fabric2, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:91:4e:d3
		IP Source: static

================================

================================
SLOT #7
================================
Name: Node 7
Health: Healthy
Health Details: 
        | Sensor ID | Sensor Name      | Value   | Health                |
         ---------------------------------------------------------------- 
        | 0x0e      | Vcc +12.0V SUS   | 12.06   | Healthy               |
        | 0x0f      | Vcc +3.3V SUS    | 3.35    | Healthy               |
        | 0x10      | Vcc +1.5V SUS    | 1.50    | Healthy               |
        | 0x11      | Vcc +1.2V SUS    | 1.21    | Healthy               |
        | 0x04      | Temp Brd Inlet   | 23.00   | Healthy               |
        | 0x05      | Temp Brd Outlet  | 25.00   | Healthy               |
        | 0x07      | Temp BMC         | 28.00   | Healthy               |
        | 0x08      | Temp CPU 1       | 0.00    | Healthy               |
        | 0x09      | Temp CPU 2       | 0.00    | Healthy               |
Hotswap Status: Inactive
Product name: 4005
Part number: T4005CXXX_2-CXX
Serial number: 9013138931
Manufacturing date: Thu Jul 28 15:37:00 2016
Type: Node
Model: MSP8022
HPM versions:
	BMC: 2.18.08FA45E0
	FPGA: 2.C.00000000
	BIOS: 0.0.00000000
Management Network:
        Management MAC: 00:a0:a5:91:4d:a0
        IP Source: dhcp
        IP: 10.24.47.99
        Subnet: 255.255.255.0
        Gateway: 10.24.47.3
        VLAN: FFD
Payload IPs :
	Network Interfaces:
		Id: 1, 
		Backplane: Base2, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:91:4d:9c
		IP Source: static


		Id: 2, 
		Backplane: Fabric1, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:91:4d:9d
		IP Source: static


	Network Interfaces:
		Id: 1, 
		Backplane: Base1, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:91:4d:9e
		IP Source: static


		Id: 2, 
		Backplane: Fabric2, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:91:4d:9f
		IP Source: static

================================

================================
SLOT #8
================================
Name: Node 8
Health: Healthy
Health Details: 
        | Sensor ID | Sensor Name      | Value   | Health                |
         ---------------------------------------------------------------- 
        | 0x0e      | Vcc +12.0V SUS   | 12.18   | Healthy               |
        | 0x0f      | Vcc +3.3V SUS    | 3.37    | Healthy               |
        | 0x10      | Vcc +1.5V SUS    | 1.50    | Healthy               |
        | 0x11      | Vcc +1.2V SUS    | 1.19    | Healthy               |
        | 0x04      | Temp Brd Inlet   | 24.00   | Healthy               |
        | 0x05      | Temp Brd Outlet  | 26.00   | Healthy               |
        | 0x07      | Temp BMC         | 28.00   | Healthy               |
        | 0x08      | Temp CPU 1       | 0.00    | Healthy               |
        | 0x09      | Temp CPU 2       | 0.00    | Healthy               |
Hotswap Status: Inactive
Product name: 4005
Part number: T4005CXXX_2-CXX
Serial number: 9013138870
Manufacturing date: Thu Jul 28 16:03:00 2016
Type: Node
Model: MSP8022
HPM versions:
	BMC: 2.18.08FA45E0
	FPGA: 2.C.00000000
	BIOS: 0.0.00000000
Management Network:
        Management MAC: 00:a0:a5:91:4f:66
        IP Source: dhcp
        IP: 10.24.47.104
        Subnet: 255.255.255.0
        Gateway: 10.24.47.3
        VLAN: FFD
Payload IPs :
	Network Interfaces:
		Id: 1, 
		Backplane: Base2, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:91:4f:62
		IP Source: static


		Id: 2, 
		Backplane: Fabric1, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:91:4f:63
		IP Source: static


	Network Interfaces:
		Id: 1, 
		Backplane: Base1, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:91:4f:64
		IP Source: static


		Id: 2, 
		Backplane: Fabric2, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:91:4f:65
		IP Source: static

================================

================================
SLOT #9
================================
Name: Node 9
Health: Healthy
Health Details: 
        | Sensor ID | Sensor Name      | Value   | Health                |
         ---------------------------------------------------------------- 
        | 0x0e      | Vcc +12.0V SUS   | 12.18   | Healthy               |
        | 0x0f      | Vcc +3.3V SUS    | 3.37    | Healthy               |
        | 0x10      | Vcc +1.5V SUS    | 1.50    | Healthy               |
        | 0x11      | Vcc +1.2V SUS    | 1.21    | Healthy               |
        | 0x04      | Temp Brd Inlet   | 25.00   | Healthy               |
        | 0x05      | Temp Brd Outlet  | 26.00   | Healthy               |
        | 0x07      | Temp BMC         | 28.00   | Healthy               |
        | 0x08      | Temp CPU 1       | 0.00    | Healthy               |
        | 0x09      | Temp CPU 2       | 0.00    | Healthy               |
Hotswap Status: Inactive
Product name: 4005
Part number: T4005CXXX_2-CXX
Serial number: 9013138837
Manufacturing date: Thu Jul 28 15:30:00 2016
Type: Node
Model: MSP8022
HPM versions:
	BMC: 2.18.08FA45E0
	FPGA: 2.C.00000000
	BIOS: 0.0.00000000
Management Network:
        Management MAC: 00:a0:a5:91:4f:28
        IP Source: dhcp
        IP: 10.24.47.132
        Subnet: 255.255.255.0
        Gateway: 10.24.47.3
        VLAN: FFD
Payload IPs :
	Network Interfaces:
		Id: 1, 
		Backplane: Base2, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:91:4f:24
		IP Source: static


		Id: 2, 
		Backplane: Fabric1, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:91:4f:25
		IP Source: static


	Network Interfaces:
		Id: 1, 
		Backplane: Base1, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:91:4f:26
		IP Source: static


		Id: 2, 
		Backplane: Fabric2, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:91:4f:27
		IP Source: static

================================

*******************************
Original JSON string
*******************************
{ "name": "Platform #1", "number": "1", "chassis": "ms2900", "health": "Green", "fans":[ {"number": "1", "name": "Fan 1", "type": "fan", "health": "Green", "rpm": "3003","alarm": {"alarmlevel": "None"}, "LedIdentify": {"status": "off"}, "hotswapStatus":{"state": "M4", "text": "Active"}}, {"number": "2", "name": "Fan 2", "type": "fan", "health": "Green", "rpm": "3157","alarm": {"alarmlevel": "None"}, "LedIdentify": {"status": "off"}, "hotswapStatus":{"state": "M4", "text": "Active"}}, {"number": "3", "name": "Fan 3", "type": "fan", "health": "Green", "rpm": "3157","alarm": {"alarmlevel": "None"}, "LedIdentify": {"status": "off"}, "hotswapStatus":{"state": "M4", "text": "Active"}}, {"number": "4", "name": "Fan 4", "type": "fan", "health": "Green", "rpm": "3157","alarm": {"alarmlevel": "None"}, "LedIdentify": {"status": "off"}, "hotswapStatus":{"state": "M4", "text": "Active"}}, {"number": "5", "name": "Fan 5", "type": "fan", "health": "Green", "rpm": "3080","alarm": {"alarmlevel": "None"}, "LedIdentify": {"status": "off"}, "hotswapStatus":{"state": "M4", "text": "Active"}} ], "type": "platform", "components": [{"number": "10", "name": "HubNode 1", "health": "Green", "fruInfo": {"mfgDate": "Thu Jun 23 12:55:00 2016", "boardMfg": "Kontron", "boardProductName": "MSH8900", "boardProductPart": "T4301X_2-X", "boardSerialNumber": "9013133544"},"hotswapStatus":{"state": "M4", "text": "Active"},"type":"hubnode", "HubNodeFeatures":{"SwitchSpeedSupport": "1", "PortModeSupport": "0"}, "versions" : [{ "name" : "BMC", "major" : "3", "minor" : "18", "revision" : "093413FB"},{ "name" : "FPGA", "major" : "2", "minor" : "04", "revision" : "00000000"}],"model": "MSH8900", "isUpdating" : "0", "managementIP": "10.24.47.113", "managementMAC": "00:a0:a5:8a:62:25", "alarm": {"alarmlevel": "None", "sensors":[]}, "LedIdentify": {"status": "off"}, "components": [{ "description": "Switch 1", "number": "1", "hotswapStatus":{"state": "M4", "text": "Active"}, "networkInterfaces": [{ "id": "1", "backplane": "Management", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:8a:62:06"}]}], "status": "Active"}, {"number": "11", "name": "HubNode 2", "health": "Green", "fruInfo": {"mfgDate": "Wed Jul  6 18:47:00 2016", "boardMfg": "Kontron", "boardProductName": "MSH8900", "boardProductPart": "T4301X_2-X", "boardSerialNumber": "9013133555"},"hotswapStatus":{"state": "M4", "text": "Active"},"type":"hubnode", "HubNodeFeatures":{"SwitchSpeedSupport": "1", "PortModeSupport": "0"}, "versions" : [{ "name" : "BMC", "major" : "3", "minor" : "18", "revision" : "093413FB"},{ "name" : "FPGA", "major" : "2", "minor" : "04", "revision" : "00000000"}],"model": "MSH8900", "isUpdating" : "0", "managementIP": "10.24.47.86", "managementMAC": "00:a0:a5:8a:ec:69", "alarm": {"alarmlevel": "None", "sensors":[]}, "LedIdentify": {"status": "off"}, "components": [{ "description": "Switch 2", "number": "1", "hotswapStatus":{"state": "M4", "text": "Active"}, "networkInterfaces": [{ "id": "1", "backplane": "Management", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:8a:ec:4a"}]}], "status": "Standby"}, {"number": "1", "name": "Node 1", "health": "Green", "fruInfo": {"mfgDate": "Thu Jul 28 16:39:00 2016", "boardMfg": "Kontron", "boardProductName": "4005", "boardProductPart": "T4005CXXX_2-CXX", "boardSerialNumber": "9013138867"},"hotswapStatus":{"state": "M1", "text": "Inactive"},"type":"node", "versions" : [{ "name" : "BMC", "major" : "2", "minor" : "18", "revision" : "08FA45E0"},{ "name" : "FPGA", "major" : "2", "minor" : "12", "revision" : "00000000"},{ "name" : "BIOS", "major" : "0", "minor" : "00", "revision" : "00000000"}],"model": "MSP8022", "isUpdating" : "0", "managementIP": "10.24.47.142", "managementMAC": "00:a0:a5:8a:97:3e", "alarm": {"alarmlevel": "None", "sensors":[]}, "LedIdentify": {"status": "off"}, "components": [{ "description": "Payload1       ", "number": "1", "hotswapStatus":{"state": "M1", "text": "Inactive"}, "networkInterfaces": [{ "id": "1", "backplane": "Base2", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:8a:97:3a"}, { "id": "2", "backplane": "Fabric1", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:8a:97:3b"}]}, { "description": "Payload2       ", "number": "2", "hotswapStatus":{"state": "M1", "text": "Inactive"}, "networkInterfaces": [{ "id": "1", "backplane": "Base1", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:8a:97:3c"}, { "id": "2", "backplane": "Fabric2", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:8a:97:3d"}]}] }, {"number": "2", "name": "Node 2", "health": "Green", "fruInfo": {"mfgDate": "Thu Jul 28 16:42:00 2016", "boardMfg": "Kontron", "boardProductName": "4005", "boardProductPart": "T4005CXXX_2-CXX", "boardSerialNumber": "9013138963"},"hotswapStatus":{"state": "M1", "text": "Inactive"},"type":"node", "versions" : [{ "name" : "BMC", "major" : "2", "minor" : "18", "revision" : "08FA45E0"},{ "name" : "FPGA", "major" : "2", "minor" : "12", "revision" : "00000000"},{ "name" : "BIOS", "major" : "0", "minor" : "00", "revision" : "00000000"}],"model": "MSP8022", "isUpdating" : "0", "managementIP": "10.24.47.169", "managementMAC": "00:a0:a5:91:4e:82", "alarm": {"alarmlevel": "None", "sensors":[]}, "LedIdentify": {"status": "off"}, "components": [{ "description": "Payload1       ", "number": "1", "hotswapStatus":{"state": "M1", "text": "Inactive"}, "networkInterfaces": [{ "id": "1", "backplane": "Base2", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:91:4e:7e"}, { "id": "2", "backplane": "Fabric1", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:91:4e:7f"}]}, { "description": "Payload2       ", "number": "2", "hotswapStatus":{"state": "M1", "text": "Inactive"}, "networkInterfaces": [{ "id": "1", "backplane": "Base1", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:91:4e:80"}, { "id": "2", "backplane": "Fabric2", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:91:4e:81"}]}] }, {"number": "3", "name": "Node 3", "health": "Green", "fruInfo": {"mfgDate": "Thu Jul 28 16:43:00 2016", "boardMfg": "Kontron", "boardProductName": "4005", "boardProductPart": "T4005CXXX_2-CXX", "boardSerialNumber": "9013138864"},"hotswapStatus":{"state": "M1", "text": "Inactive"},"type":"node", "versions" : [{ "name" : "BMC", "major" : "2", "minor" : "18", "revision" : "08FA45E0"},{ "name" : "FPGA", "major" : "2", "minor" : "12", "revision" : "00000000"},{ "name" : "BIOS", "major" : "0", "minor" : "00", "revision" : "00000000"}],"model": "MSP8022", "isUpdating" : "0", "managementIP": "10.24.47.188", "managementMAC": "00:a0:a5:91:4c:80", "alarm": {"alarmlevel": "None", "sensors":[]}, "LedIdentify": {"status": "off"}, "components": [{ "description": "Payload1       ", "number": "1", "hotswapStatus":{"state": "M1", "text": "Inactive"}, "networkInterfaces": [{ "id": "1", "backplane": "Base2", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:91:4c:7c"}, { "id": "2", "backplane": "Fabric1", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:91:4c:7d"}]}, { "description": "Payload2       ", "number": "2", "hotswapStatus":{"state": "M1", "text": "Inactive"}, "networkInterfaces": [{ "id": "1", "backplane": "Base1", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:91:4c:7e"}, { "id": "2", "backplane": "Fabric2", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:91:4c:7f"}]}] }, {"number": "4", "name": "Node 4", "health": "Green", "fruInfo": {"mfgDate": "Thu Jul 28 15:54:00 2016", "boardMfg": "Kontron", "boardProductName": "4005", "boardProductPart": "T4005CXXX_2-CXX", "boardSerialNumber": "9013138918"},"hotswapStatus":{"state": "M1", "text": "Inactive"},"type":"node", "versions" : [{ "name" : "BMC", "major" : "2", "minor" : "18", "revision" : "08FA45E0"},{ "name" : "FPGA", "major" : "2", "minor" : "12", "revision" : "00000000"},{ "name" : "BIOS", "major" : "0", "minor" : "00", "revision" : "00000000"}],"model": "MSP8022", "isUpdating" : "0", "managementIP": "10.24.47.172", "managementMAC": "00:a0:a5:91:4e:e0", "alarm": {"alarmlevel": "None", "sensors":[]}, "LedIdentify": {"status": "off"}, "components": [{ "description": "Payload1       ", "number": "1", "hotswapStatus":{"state": "M1", "text": "Inactive"}, "networkInterfaces": [{ "id": "1", "backplane": "Base2", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:91:4e:dc"}, { "id": "2", "backplane": "Fabric1", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:91:4e:dd"}]}, { "description": "Payload2       ", "number": "2", "hotswapStatus":{"state": "M1", "text": "Inactive"}, "networkInterfaces": [{ "id": "1", "backplane": "Base1", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:91:4e:de"}, { "id": "2", "backplane": "Fabric2", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:91:4e:df"}]}] }, {"number": "5", "name": "Node 5", "health": "Green", "fruInfo": {"mfgDate": "Thu Jul 28 15:53:00 2016", "boardMfg": "Kontron", "boardProductName": "4005", "boardProductPart": "T4005CXXX_2-CXX", "boardSerialNumber": "9013138719"},"hotswapStatus":{"state": "M1", "text": "Inactive"},"type":"node", "versions" : [{ "name" : "BMC", "major" : "2", "minor" : "18", "revision" : "08FA45E0"},{ "name" : "FPGA", "major" : "2", "minor" : "12", "revision" : "00000000"},{ "name" : "BIOS", "major" : "0", "minor" : "00", "revision" : "00000000"}],"model": "MSP8022", "isUpdating" : "0", "managementIP": "10.24.47.105", "managementMAC": "00:a0:a5:91:4f:40", "alarm": {"alarmlevel": "None", "sensors":[]}, "LedIdentify": {"status": "off"}, "components": [{ "description": "Payload1       ", "number": "1", "hotswapStatus":{"state": "M1", "text": "Inactive"}, "networkInterfaces": [{ "id": "1", "backplane": "Base2", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:91:4f:3c"}, { "id": "2", "backplane": "Fabric1", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:91:4f:3d"}]}, { "description": "Payload2       ", "number": "2", "hotswapStatus":{"state": "M1", "text": "Inactive"}, "networkInterfaces": [{ "id": "1", "backplane": "Base1", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:91:4f:3e"}, { "id": "2", "backplane": "Fabric2", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:91:4f:3f"}]}] }, {"number": "6", "name": "Node 6", "health": "Green", "fruInfo": {"mfgDate": "Thu Jul 28 16:27:00 2016", "boardMfg": "Kontron", "boardProductName": "4005", "boardProductPart": "T4005CXXX_2-CXX", "boardSerialNumber": "9013138877"},"hotswapStatus":{"state": "M1", "text": "Inactive"},"type":"node", "versions" : [{ "name" : "BMC", "major" : "2", "minor" : "18", "revision" : "08FA45E0"},{ "name" : "FPGA", "major" : "2", "minor" : "12", "revision" : "00000000"},{ "name" : "BIOS", "major" : "0", "minor" : "00", "revision" : "00000000"}],"model": "MSP8022", "isUpdating" : "0", "managementIP": "10.24.47.164", "managementMAC": "00:a0:a5:91:4e:d4", "alarm": {"alarmlevel": "None", "sensors":[]}, "LedIdentify": {"status": "off"}, "components": [{ "description": "Payload1       ", "number": "1", "hotswapStatus":{"state": "M1", "text": "Inactive"}, "networkInterfaces": [{ "id": "1", "backplane": "Base2", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:91:4e:d0"}, { "id": "2", "backplane": "Fabric1", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:91:4e:d1"}]}, { "description": "Payload2       ", "number": "2", "hotswapStatus":{"state": "M1", "text": "Inactive"}, "networkInterfaces": [{ "id": "1", "backplane": "Base1", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:91:4e:d2"}, { "id": "2", "backplane": "Fabric2", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:91:4e:d3"}]}] }, {"number": "7", "name": "Node 7", "health": "Green", "fruInfo": {"mfgDate": "Thu Jul 28 15:37:00 2016", "boardMfg": "Kontron", "boardProductName": "4005", "boardProductPart": "T4005CXXX_2-CXX", "boardSerialNumber": "9013138931"},"hotswapStatus":{"state": "M1", "text": "Inactive"},"type":"node", "versions" : [{ "name" : "BMC", "major" : "2", "minor" : "18", "revision" : "08FA45E0"},{ "name" : "FPGA", "major" : "2", "minor" : "12", "revision" : "00000000"},{ "name" : "BIOS", "major" : "0", "minor" : "00", "revision" : "00000000"}],"model": "MSP8022", "isUpdating" : "0", "managementIP": "10.24.47.99", "managementMAC": "00:a0:a5:91:4d:a0", "alarm": {"alarmlevel": "None", "sensors":[]}, "LedIdentify": {"status": "off"}, "components": [{ "description": "Payload1       ", "number": "1", "hotswapStatus":{"state": "M1", "text": "Inactive"}, "networkInterfaces": [{ "id": "1", "backplane": "Base2", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:91:4d:9c"}, { "id": "2", "backplane": "Fabric1", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:91:4d:9d"}]}, { "description": "Payload2       ", "number": "2", "hotswapStatus":{"state": "M1", "text": "Inactive"}, "networkInterfaces": [{ "id": "1", "backplane": "Base1", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:91:4d:9e"}, { "id": "2", "backplane": "Fabric2", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:91:4d:9f"}]}] }, {"number": "8", "name": "Node 8", "health": "Green", "fruInfo": {"mfgDate": "Thu Jul 28 16:03:00 2016", "boardMfg": "Kontron", "boardProductName": "4005", "boardProductPart": "T4005CXXX_2-CXX", "boardSerialNumber": "9013138870"},"hotswapStatus":{"state": "M1", "text": "Inactive"},"type":"node", "versions" : [{ "name" : "BMC", "major" : "2", "minor" : "18", "revision" : "08FA45E0"},{ "name" : "FPGA", "major" : "2", "minor" : "12", "revision" : "00000000"},{ "name" : "BIOS", "major" : "0", "minor" : "00", "revision" : "00000000"}],"model": "MSP8022", "isUpdating" : "0", "managementIP": "10.24.47.104", "managementMAC": "00:a0:a5:91:4f:66", "alarm": {"alarmlevel": "None", "sensors":[]}, "LedIdentify": {"status": "off"}, "components": [{ "description": "Payload1       ", "number": "1", "hotswapStatus":{"state": "M1", "text": "Inactive"}, "networkInterfaces": [{ "id": "1", "backplane": "Base2", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:91:4f:62"}, { "id": "2", "backplane": "Fabric1", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:91:4f:63"}]}, { "description": "Payload2       ", "number": "2", "hotswapStatus":{"state": "M1", "text": "Inactive"}, "networkInterfaces": [{ "id": "1", "backplane": "Base1", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:91:4f:64"}, { "id": "2", "backplane": "Fabric2", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:91:4f:65"}]}] }, {"number": "9", "name": "Node 9", "health": "Green", "fruInfo": {"mfgDate": "Thu Jul 28 15:30:00 2016", "boardMfg": "Kontron", "boardProductName": "4005", "boardProductPart": "T4005CXXX_2-CXX", "boardSerialNumber": "9013138837"},"hotswapStatus":{"state": "M1", "text": "Inactive"},"type":"node", "versions" : [{ "name" : "BMC", "major" : "2", "minor" : "18", "revision" : "08FA45E0"},{ "name" : "FPGA", "major" : "2", "minor" : "12", "revision" : "00000000"},{ "name" : "BIOS", "major" : "0", "minor" : "00", "revision" : "00000000"}],"model": "MSP8022", "isUpdating" : "0", "managementIP": "10.24.47.132", "managementMAC": "00:a0:a5:91:4f:28", "alarm": {"alarmlevel": "None", "sensors":[]}, "LedIdentify": {"status": "off"}, "components": [{ "description": "Payload1       ", "number": "1", "hotswapStatus":{"state": "M1", "text": "Inactive"}, "networkInterfaces": [{ "id": "1", "backplane": "Base2", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:91:4f:24"}, { "id": "2", "backplane": "Fabric1", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:91:4f:25"}]}, { "description": "Payload2       ", "number": "2", "hotswapStatus":{"state": "M1", "text": "Inactive"}, "networkInterfaces": [{ "id": "1", "backplane": "Base1", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:91:4f:26"}, { "id": "2", "backplane": "Fabric2", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:91:4f:27"}]}] }, { "name": "PSU", "components": [{"id": "PSU1", "number": "1", "name": "Power Supply 1", "health": "Green", "type": "psu", "hotswapStatus":{"state": "M4", "text": "Active"},"alarm": {"alarmlevel": "None"}, "tempInlet": "25.00", "tempOutlet": "32.00", "vIn": "206.00", "powerOut": "32", "powerScale": "1400","peakConsumption": "48", "averageConsumption": "38"},{"id": "PSU2", "number": "2", "name": "Power Supply 2", "health": "Green", "type": "psu", "hotswapStatus":{"state": "M4", "text": "Active"},"alarm": {"alarmlevel": "None"}, "tempInlet": "25.00", "tempOutlet": "32.00", "vIn": "204.00", "powerOut": "40", "powerScale": "1400","peakConsumption": "48", "averageConsumption": "40"}]}], "switchOID": {"oid": "1.3.6.1.4.1.6603"}, "alarm": {"alarmlevel": "None",  "components" : [ {"nodes" : [] } , {"psu" : [] }, {"fans" : [] }], "text": ""}, "LedIdentify": {"status": "off"}}
