System informations
*******************************
Name: SYMKLOUD
chassis: ms2900
Health: Healthy
*******************************
Fans: 
*******************************
Fan 1: 
	Present :true
	Status :Healthy
	8008 RPM
Fan 2: 
	Present :true
	Status :Healthy
	8239 RPM
Fan 3: 
	Present :true
	Status :Healthy
	8085 RPM
Fan 4: 
	Present :true
	Status :Healthy
	8316 RPM
Fan 5: 
	Present :true
	Status :Healthy
	8085 RPM


*******************************
PSU: 
*******************************
Name: PSU 1
Health: Healthy
Health Details: No details available
Hotswap Status: Active
FRU: Informations are invalid

Name: PSU 2
Health: Healthy
Health Details: No details available
Hotswap Status: Active
FRU: Informations are invalid



*******************************
HubNodes
*******************************

================================
Name: HubNode 1
Health: Healthy
Health Details: 
        | Sensor ID | Sensor Name      | Value   | Health                |
         ---------------------------------------------------------------- 
        | 0x0b      | Temp On-Board    | 29.00   | Healthy               |
        | 0x0c      | Temp Eth Switch  | 29.00   | Healthy               |
        | 0x0d      | Temp Quad Phy    | 34.00   | Healthy               |
        | 0x0e      | Temp Inlet       | 21.00   | Healthy               |
        | 0x0f      | Temp Phy 10G     | 51.00   | Healthy               |
        | 0x10      | Vcc +12V In      | 12.18   | Healthy               |
        | 0x11      | Vcc +5V SUS      | 5.05    | Healthy               |
        | 0x12      | Vcc +3.3V SUS    | 3.31    | Healthy               |
        | 0x13      | Vcc +1.8V SUS    | 1.78    | Healthy               |
        | 0x14      | Vcc +1.5V SUS    | 1.51    | Healthy               |
        | 0x15      | Vcc +1.25V SUS   | 1.24    | Healthy               |
        | 0x16      | Vcc +1.2V SUS    | 1.19    | Healthy               |
        | 0x17      | Vcc +0.75V SUS   | 0.75    | Healthy               |
        | 0x18      | Vcc +3.3V        | 3.29    | Healthy               |
        | 0x19      | Vcc +2.5V        | 2.47    | Healthy               |
        | 0x1a      | Vcc +1.8V        | 1.78    | Healthy               |
        | 0x1b      | Vcc +1.2V        | 1.21    | Healthy               |
        | 0x1c      | Vcc +1.0V        | 1.01    | Healthy               |
        | 0x1d      | Vbat +3V         | 3.03    | Healthy               |
        | 0x3f      | Power Good Latch | 0x8001  | Healthy               |
        | 0x40      | FPGA RW Status   | 0x8002  | Healthy               |
        | 0x41      | FPGA Heartbeat   | 0x8002  | Healthy               |
        | 0x48      | ShMC Redun State | 0x8002  | Healthy               |
Hotswap Status: Active
Product name: MSH8900
Part number: T4301X_2-X
Serial number: 9017009215
Manufacturing date: Thu Oct 18 15:28:00 2018
Type: HubNode
Status: Active
Model: MSH8900
HPM versions:
	BMC: 3.16.09289D46
	FPGA: 2.6.00000000
Management Network:
        Management MAC: 00:a0:a5:cf:0e:3d
        IP Source: dhcp
        IP: 10.24.98.76
        Subnet: 255.255.255.0
        Gateway: 10.24.98.3
        VLAN: FFD
Payload IPs :
	Network Interfaces:
		Id: 1, 
		Backplane: Unknown, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:cf:0e:3d
		IP Source: static

================================

================================
Name: HubNode 2
Health: Healthy
Health Details: 
        | Sensor ID | Sensor Name      | Value   | Health                |
         ---------------------------------------------------------------- 
        | 0x0b      | Temp On-Board    | 28.00   | Healthy               |
        | 0x0c      | Temp Eth Switch  | 29.00   | Healthy               |
        | 0x0d      | Temp Quad Phy    | 34.00   | Healthy               |
        | 0x0e      | Temp Inlet       | 21.00   | Healthy               |
        | 0x0f      | Temp Phy 10G     | 48.00   | Healthy               |
        | 0x10      | Vcc +12V In      | 12.18   | Healthy               |
        | 0x11      | Vcc +5V SUS      | 5.05    | Healthy               |
        | 0x12      | Vcc +3.3V SUS    | 3.29    | Healthy               |
        | 0x13      | Vcc +1.8V SUS    | 1.78    | Healthy               |
        | 0x14      | Vcc +1.5V SUS    | 1.50    | Healthy               |
        | 0x15      | Vcc +1.25V SUS   | 1.25    | Healthy               |
        | 0x16      | Vcc +1.2V SUS    | 1.19    | Healthy               |
        | 0x17      | Vcc +0.75V SUS   | 0.75    | Healthy               |
        | 0x18      | Vcc +3.3V        | 3.29    | Healthy               |
        | 0x19      | Vcc +2.5V        | 2.48    | Healthy               |
        | 0x1a      | Vcc +1.8V        | 1.78    | Healthy               |
        | 0x1b      | Vcc +1.2V        | 1.21    | Healthy               |
        | 0x1c      | Vcc +1.0V        | 1.01    | Healthy               |
        | 0x1d      | Vbat +3V         | 3.04    | Healthy               |
        | 0x3f      | Power Good Latch | 0x8001  | Healthy               |
        | 0x40      | FPGA RW Status   | 0x8002  | Healthy               |
        | 0x41      | FPGA Heartbeat   | 0x8002  | Healthy               |
        | 0x48      | ShMC Redun State | 0x8008  | Healthy               |
Hotswap Status: Active
Product name: MSH8900
Part number: T4301X_2-X
Serial number: 9017009221
Manufacturing date: Thu Oct 18 15:27:00 2018
Type: HubNode
Status: Standby
Model: MSH8900
HPM versions:
	BMC: 3.16.09289D46
	FPGA: 2.6.00000000
Management Network:
        Management MAC: 00:a0:a5:cf:0e:b1
        IP Source: dhcp
        IP: 10.24.98.75
        Subnet: 255.255.255.0
        Gateway: 10.24.98.3
        VLAN: FFD
Payload IPs :
	Network Interfaces:
		Id: 1, 
		Backplane: Unknown, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:cf:0e:b1
		IP Source: static

================================

*******************************
Nodes
*******************************

================================
SLOT #1
================================
Name: Node 1
Health: Healthy
Health Details: 
        | Sensor ID | Sensor Name      | Value   | Health                |
         ---------------------------------------------------------------- 
        | 0x0e      | Vcc +12V SUS     | 12.06   | Healthy               |
        | 0x0f      | Vcc +5V SUS      | 4.96    | Healthy               |
        | 0x10      | Vcc +2.5V SUS    | 2.48    | Healthy               |
        | 0x11      | Vcc +1.8V SUS    | 1.81    | Healthy               |
        | 0x12      | Vcc +1.5V SUS    | 1.50    | Healthy               |
        | 0x13      | Vcc +1.25V SUS   | 1.24    | Healthy               |
        | 0x14      | Vcc +0.75V SUS   | 0.75    | Healthy               |
        | 0x04      | Temp Inlet       | 21.00   | Healthy               |
        | 0x05      | Temp Outlet      | 22.00   | Healthy               |
        | 0x07      | Temp BMC         | 29.00   | Healthy               |
        | 0x08      | Temp CPU 1       | 0.00    | Healthy               |
        | 0x09      | Temp CPU 2       | 0.00    | Healthy               |
Hotswap Status: Active
Product name: 4009
Part number: 1062-0224
Serial number: 9017009621
Manufacturing date: Wed Oct 17 13:32:00 2018
Type: Node
Model: MSP805x
HPM versions:
	BMC: 1.3.091805DF
	FPGA: 1.0.00000000
	BIOS: 1.1.0916DD5E
Management Network:
        Management MAC: 00:a0:a5:ce:65:54
        IP Source: dhcp
        IP: 10.24.98.113
        Subnet: 255.255.255.0
        Gateway: 10.24.98.3
        VLAN: FFD
Payload IPs :
	Network Interfaces:
		Id: 1, 
		Backplane: Base2, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:ce:65:4e
		IP Source: static


		Id: 2, 
		Backplane: Fabric1p1, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:ce:65:4f
		IP Source: static


		Id: 3, 
		Backplane: Fabric2p2, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:ce:65:50
		IP Source: static


	Network Interfaces:
		Id: 1, 
		Backplane: Base1, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:ce:65:51
		IP Source: static


		Id: 2, 
		Backplane: Fabric1p2, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:ce:65:52
		IP Source: static


		Id: 3, 
		Backplane: Fabric2p1, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:ce:65:53
		IP Source: static

================================

================================
SLOT #2
================================
Name: Node 2
Health: Healthy
Health Details: 
        | Sensor ID | Sensor Name      | Value   | Health                |
         ---------------------------------------------------------------- 
        | 0x0e      | Vcc +12V SUS     | 12.12   | Healthy               |
        | 0x0f      | Vcc +5V SUS      | 4.96    | Healthy               |
        | 0x10      | Vcc +2.5V SUS    | 2.49    | Healthy               |
        | 0x11      | Vcc +1.8V SUS    | 1.80    | Healthy               |
        | 0x12      | Vcc +1.5V SUS    | 1.49    | Healthy               |
        | 0x13      | Vcc +1.25V SUS   | 1.24    | Healthy               |
        | 0x14      | Vcc +0.75V SUS   | 0.75    | Healthy               |
        | 0x04      | Temp Inlet       | 21.00   | Healthy               |
        | 0x05      | Temp Outlet      | 23.00   | Healthy               |
        | 0x07      | Temp BMC         | 29.00   | Healthy               |
        | 0x08      | Temp CPU 1       | 0.00    | Healthy               |
        | 0x09      | Temp CPU 2       | 0.00    | Healthy               |
Hotswap Status: Active
Product name: 4009
Part number: 1062-0224
Serial number: 9017048215
Manufacturing date: Mon May  4 16:51:00 2020
Type: Node
Model: MSP805x
HPM versions:
	BMC: 1.6.09289DBB
	FPGA: 1.0.00000000
	BIOS: 1.5.0926BD66
Management Network:
        Management MAC: 00:a0:a5:db:ea:f2
        IP Source: dhcp
        IP: 10.24.98.180
        Subnet: 255.255.255.0
        Gateway: 10.24.98.3
        VLAN: FFD
Payload IPs :
	Network Interfaces:
		Id: 1, 
		Backplane: Base2, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:db:ea:ec
		IP Source: static


		Id: 2, 
		Backplane: Fabric1p1, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:db:ea:ed
		IP Source: static


		Id: 3, 
		Backplane: Fabric2p2, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:db:ea:ee
		IP Source: static


	Network Interfaces:
		Id: 1, 
		Backplane: Base1, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:db:ea:ef
		IP Source: static


		Id: 2, 
		Backplane: Fabric1p2, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:db:ea:f0
		IP Source: static


		Id: 3, 
		Backplane: Fabric2p1, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:db:ea:f1
		IP Source: static

================================

================================
SLOT #3
================================
Name: Node 3
Health: Healthy
Health Details: 
        | Sensor ID | Sensor Name      | Value   | Health                |
         ---------------------------------------------------------------- 
        | 0x0e      | Vcc +12V SUS     | 12.06   | Healthy               |
        | 0x0f      | Vcc +5V SUS      | 5.01    | Healthy               |
        | 0x10      | Vcc +2.5V SUS    | 2.48    | Healthy               |
        | 0x11      | Vcc +1.8V SUS    | 1.81    | Healthy               |
        | 0x12      | Vcc +1.5V SUS    | 1.49    | Healthy               |
        | 0x13      | Vcc +1.25V SUS   | 1.26    | Healthy               |
        | 0x14      | Vcc +0.75V SUS   | 0.75    | Healthy               |
        | 0x04      | Temp Inlet       | 21.00   | Healthy               |
        | 0x05      | Temp Outlet      | 22.00   | Healthy               |
        | 0x07      | Temp BMC         | 29.00   | Healthy               |
        | 0x08      | Temp CPU 1       | 0.00    | Healthy               |
        | 0x09      | Temp CPU 2       | 0.00    | Healthy               |
Hotswap Status: Active
Product name: 4009
Part number: 1062-0224
Serial number: 9017009422
Manufacturing date: Wed Oct 17 13:31:00 2018
Type: Node
Model: MSP805x
HPM versions:
	BMC: 1.3.091805DF
	FPGA: 1.0.00000000
	BIOS: 1.1.0916DD5E
Management Network:
        Management MAC: 00:a0:a5:ce:65:bc
        IP Source: dhcp
        IP: 10.24.98.186
        Subnet: 255.255.255.0
        Gateway: 10.24.98.3
        VLAN: FFD
Payload IPs :
	Network Interfaces:
		Id: 1, 
		Backplane: Base2, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:ce:65:b6
		IP Source: static


		Id: 2, 
		Backplane: Fabric1p1, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:ce:65:b7
		IP Source: static


		Id: 3, 
		Backplane: Fabric2p2, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:ce:65:b8
		IP Source: static


	Network Interfaces:
		Id: 1, 
		Backplane: Base1, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:ce:65:b9
		IP Source: static


		Id: 2, 
		Backplane: Fabric1p2, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:ce:65:ba
		IP Source: static


		Id: 3, 
		Backplane: Fabric2p1, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:ce:65:bb
		IP Source: static

================================

================================
SLOT #4
================================
Name: Node 4
Health: Healthy
Health Details: 
        | Sensor ID | Sensor Name      | Value   | Health                |
         ---------------------------------------------------------------- 
        | 0x0e      | Vcc +12V SUS     | 12.06   | Healthy               |
        | 0x0f      | Vcc +5V SUS      | 4.96    | Healthy               |
        | 0x10      | Vcc +2.5V SUS    | 2.49    | Healthy               |
        | 0x11      | Vcc +1.8V SUS    | 1.80    | Healthy               |
        | 0x12      | Vcc +1.5V SUS    | 1.49    | Healthy               |
        | 0x13      | Vcc +1.25V SUS   | 1.24    | Healthy               |
        | 0x14      | Vcc +0.75V SUS   | 0.74    | Healthy               |
        | 0x04      | Temp Inlet       | 21.00   | Healthy               |
        | 0x05      | Temp Outlet      | 22.00   | Healthy               |
        | 0x07      | Temp BMC         | 29.00   | Healthy               |
        | 0x08      | Temp CPU 1       | 0.00    | Healthy               |
        | 0x09      | Temp CPU 2       | 0.00    | Healthy               |
Hotswap Status: Active
Product name: 4009
Part number: 1062-0224
Serial number: 9017009562
Manufacturing date: Wed Oct 17 12:28:00 2018
Type: Node
Model: MSP805x
HPM versions:
	BMC: 1.3.091805DF
	FPGA: 1.0.00000000
	BIOS: 1.1.0916DD5E
Management Network:
        Management MAC: 00:a0:a5:cf:0e:c0
        IP Source: dhcp
        IP: 10.24.98.73
        Subnet: 255.255.255.0
        Gateway: 10.24.98.3
        VLAN: FFD
Payload IPs :
	Network Interfaces:
		Id: 1, 
		Backplane: Base2, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:cf:0e:ba
		IP Source: static


		Id: 2, 
		Backplane: Fabric1p1, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:cf:0e:bb
		IP Source: static


		Id: 3, 
		Backplane: Fabric2p2, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:cf:0e:bc
		IP Source: static


	Network Interfaces:
		Id: 1, 
		Backplane: Base1, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:cf:0e:bd
		IP Source: static


		Id: 2, 
		Backplane: Fabric1p2, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:cf:0e:be
		IP Source: static


		Id: 3, 
		Backplane: Fabric2p1, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:cf:0e:bf
		IP Source: static

================================

================================
SLOT #5
================================
Name: Node 5
Health: Healthy
Health Details: 
        | Sensor ID | Sensor Name      | Value   | Health                |
         ---------------------------------------------------------------- 
        | 0x0e      | Vcc +12V SUS     | 12.12   | Healthy               |
        | 0x0f      | Vcc +5V SUS      | 4.98    | Healthy               |
        | 0x10      | Vcc +2.5V SUS    | 2.48    | Healthy               |
        | 0x11      | Vcc +1.8V SUS    | 1.81    | Healthy               |
        | 0x12      | Vcc +1.5V SUS    | 1.50    | Healthy               |
        | 0x13      | Vcc +1.25V SUS   | 1.24    | Healthy               |
        | 0x14      | Vcc +0.75V SUS   | 0.75    | Healthy               |
        | 0x04      | Temp Inlet       | 21.00   | Healthy               |
        | 0x05      | Temp Outlet      | 22.00   | Healthy               |
        | 0x07      | Temp BMC         | 29.00   | Healthy               |
        | 0x08      | Temp CPU 1       | 0.00    | Healthy               |
        | 0x09      | Temp CPU 2       | 0.00    | Healthy               |
Hotswap Status: Active
Product name: 4009
Part number: 1062-0224
Serial number: 9017009525
Manufacturing date: Wed Oct 17 12:27:00 2018
Type: Node
Model: MSP805x
HPM versions:
	BMC: 1.3.091805DF
	FPGA: 1.0.00000000
	BIOS: 1.1.0916DD5E
Management Network:
        Management MAC: 00:a0:a5:cf:0f:a8
        IP Source: dhcp
        IP: 10.24.98.104
        Subnet: 255.255.255.0
        Gateway: 10.24.98.3
        VLAN: FFD
Payload IPs :
	Network Interfaces:
		Id: 1, 
		Backplane: Base2, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:cf:0f:a2
		IP Source: static


		Id: 2, 
		Backplane: Fabric1p1, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:cf:0f:a3
		IP Source: static


		Id: 3, 
		Backplane: Fabric2p2, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:cf:0f:a4
		IP Source: static


	Network Interfaces:
		Id: 1, 
		Backplane: Base1, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:cf:0f:a5
		IP Source: static


		Id: 2, 
		Backplane: Fabric1p2, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:cf:0f:a6
		IP Source: static


		Id: 3, 
		Backplane: Fabric2p1, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:cf:0f:a7
		IP Source: static

================================

================================
SLOT #6
================================
Name: Node 6
Health: Healthy
Health Details: 
        | Sensor ID | Sensor Name      | Value   | Health                |
         ---------------------------------------------------------------- 
        | 0x0e      | Vcc +12V SUS     | 12.06   | Healthy               |
        | 0x0f      | Vcc +5V SUS      | 5.01    | Healthy               |
        | 0x10      | Vcc +2.5V SUS    | 2.48    | Healthy               |
        | 0x11      | Vcc +1.8V SUS    | 1.81    | Healthy               |
        | 0x12      | Vcc +1.5V SUS    | 1.50    | Healthy               |
        | 0x13      | Vcc +1.25V SUS   | 1.26    | Healthy               |
        | 0x14      | Vcc +0.75V SUS   | 0.75    | Healthy               |
        | 0x04      | Temp Inlet       | 21.00   | Healthy               |
        | 0x05      | Temp Outlet      | 22.00   | Healthy               |
        | 0x07      | Temp BMC         | 29.00   | Healthy               |
        | 0x08      | Temp CPU 1       | 0.00    | Healthy               |
        | 0x09      | Temp CPU 2       | 0.00    | Healthy               |
Hotswap Status: Active
Product name: 4009
Part number: 1062-0224
Serial number: 9017009296
Manufacturing date: Wed Oct 17 13:30:00 2018
Type: Node
Model: MSP805x
HPM versions:
	BMC: 1.3.091805DF
	FPGA: 1.0.00000000
	BIOS: 1.1.0916DD5E
Management Network:
        Management MAC: 00:a0:a5:ce:63:9c
        IP Source: dhcp
        IP: 10.24.98.54
        Subnet: 255.255.255.0
        Gateway: 10.24.98.3
        VLAN: FFD
Payload IPs :
	Network Interfaces:
		Id: 1, 
		Backplane: Base2, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:ce:63:96
		IP Source: static


		Id: 2, 
		Backplane: Fabric1p1, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:ce:63:97
		IP Source: static


		Id: 3, 
		Backplane: Fabric2p2, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:ce:63:98
		IP Source: static


	Network Interfaces:
		Id: 1, 
		Backplane: Base1, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:ce:63:99
		IP Source: static


		Id: 2, 
		Backplane: Fabric1p2, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:ce:63:9a
		IP Source: static


		Id: 3, 
		Backplane: Fabric2p1, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:ce:63:9b
		IP Source: static

================================

================================
SLOT #7
================================
Name: Node 7
Health: Healthy
Health Details: 
        | Sensor ID | Sensor Name      | Value   | Health                |
         ---------------------------------------------------------------- 
        | 0x0e      | Vcc +12V SUS     | 12.12   | Healthy               |
        | 0x0f      | Vcc +5V SUS      | 5.01    | Healthy               |
        | 0x10      | Vcc +2.5V SUS    | 2.50    | Healthy               |
        | 0x11      | Vcc +1.8V SUS    | 1.81    | Healthy               |
        | 0x12      | Vcc +1.5V SUS    | 1.50    | Healthy               |
        | 0x13      | Vcc +1.25V SUS   | 1.24    | Healthy               |
        | 0x14      | Vcc +0.75V SUS   | 0.75    | Healthy               |
        | 0x04      | Temp Inlet       | 21.00   | Healthy               |
        | 0x05      | Temp Outlet      | 21.00   | Healthy               |
        | 0x07      | Temp BMC         | 29.00   | Healthy               |
        | 0x08      | Temp CPU 1       | 0.00    | Healthy               |
        | 0x09      | Temp CPU 2       | 0.00    | Healthy               |
Hotswap Status: Active
Product name: 4009
Part number: 1062-0224
Serial number: 9017009325
Manufacturing date: Wed Oct 17 15:24:00 2018
Type: Node
Model: MSP805x
HPM versions:
	BMC: 1.3.091805DF
	FPGA: 1.0.00000000
	BIOS: 1.1.0916DD5E
Management Network:
        Management MAC: 00:a0:a5:cf:0f:8c
        IP Source: dhcp
        IP: 10.24.98.145
        Subnet: 255.255.255.0
        Gateway: 10.24.98.3
        VLAN: FFD
Payload IPs :
	Network Interfaces:
		Id: 1, 
		Backplane: Base2, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:cf:0f:86
		IP Source: static


		Id: 2, 
		Backplane: Fabric1p1, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:cf:0f:87
		IP Source: static


		Id: 3, 
		Backplane: Fabric2p2, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:cf:0f:88
		IP Source: static


	Network Interfaces:
		Id: 1, 
		Backplane: Base1, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:cf:0f:89
		IP Source: static


		Id: 2, 
		Backplane: Fabric1p2, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:cf:0f:8a
		IP Source: static


		Id: 3, 
		Backplane: Fabric2p1, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:cf:0f:8b
		IP Source: static

================================

================================
SLOT #8
================================
Name: Node 8
Health: Healthy
Health Details: 
        | Sensor ID | Sensor Name      | Value   | Health                |
         ---------------------------------------------------------------- 
        | 0x0e      | Vcc +12V SUS     | 12.12   | Healthy               |
        | 0x0f      | Vcc +5V SUS      | 5.03    | Healthy               |
        | 0x10      | Vcc +2.5V SUS    | 2.49    | Healthy               |
        | 0x11      | Vcc +1.8V SUS    | 1.81    | Healthy               |
        | 0x12      | Vcc +1.5V SUS    | 1.50    | Healthy               |
        | 0x13      | Vcc +1.25V SUS   | 1.24    | Healthy               |
        | 0x14      | Vcc +0.75V SUS   | 0.75    | Healthy               |
        | 0x04      | Temp Inlet       | 21.00   | Healthy               |
        | 0x05      | Temp Outlet      | 22.00   | Healthy               |
        | 0x07      | Temp BMC         | 29.00   | Healthy               |
        | 0x08      | Temp CPU 1       | 0.00    | Healthy               |
        | 0x09      | Temp CPU 2       | 0.00    | Healthy               |
Hotswap Status: Active
Product name: 4009
Part number: 1062-0224
Serial number: 9017009496
Manufacturing date: Wed Oct 17 15:24:00 2018
Type: Node
Model: MSP805x
HPM versions:
	BMC: 1.3.091805DF
	FPGA: 1.0.00000000
	BIOS: 1.1.0916DD5E
Management Network:
        Management MAC: 00:a0:a5:cf:0f:84
        IP Source: dhcp
        IP: 10.24.98.160
        Subnet: 255.255.255.0
        Gateway: 10.24.98.3
        VLAN: FFD
Payload IPs :
	Network Interfaces:
		Id: 1, 
		Backplane: Base2, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:cf:0f:7e
		IP Source: static


		Id: 2, 
		Backplane: Fabric1p1, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:cf:0f:7f
		IP Source: static


		Id: 3, 
		Backplane: Fabric2p2, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:cf:0f:80
		IP Source: static


	Network Interfaces:
		Id: 1, 
		Backplane: Base1, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:cf:0f:81
		IP Source: static


		Id: 2, 
		Backplane: Fabric1p2, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:cf:0f:82
		IP Source: static


		Id: 3, 
		Backplane: Fabric2p1, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:cf:0f:83
		IP Source: static

================================

================================
SLOT #9
================================
Name: Node 9
Health: Healthy
Health Details: 
        | Sensor ID | Sensor Name      | Value   | Health                |
         ---------------------------------------------------------------- 
        | 0x0e      | Vcc +12V SUS     | 12.06   | Healthy               |
        | 0x0f      | Vcc +5V SUS      | 4.98    | Healthy               |
        | 0x10      | Vcc +2.5V SUS    | 2.48    | Healthy               |
        | 0x11      | Vcc +1.8V SUS    | 1.81    | Healthy               |
        | 0x12      | Vcc +1.5V SUS    | 1.49    | Healthy               |
        | 0x13      | Vcc +1.25V SUS   | 1.26    | Healthy               |
        | 0x14      | Vcc +0.75V SUS   | 0.75    | Healthy               |
        | 0x04      | Temp Inlet       | 21.00   | Healthy               |
        | 0x05      | Temp Outlet      | 22.00   | Healthy               |
        | 0x07      | Temp BMC         | 29.00   | Healthy               |
        | 0x08      | Temp CPU 1       | 0.00    | Healthy               |
        | 0x09      | Temp CPU 2       | 0.00    | Healthy               |
Hotswap Status: Active
Product name: 4009
Part number: 1062-0224
Serial number: 9017009585
Manufacturing date: Wed Oct 17 14:14:00 2018
Type: Node
Model: MSP805x
HPM versions:
	BMC: 1.3.091805DF
	FPGA: 1.0.00000000
	BIOS: 1.1.0916DD5E
Management Network:
        Management MAC: 00:a0:a5:cf:0e:d0
        IP Source: dhcp
        IP: 10.24.98.97
        Subnet: 255.255.255.0
        Gateway: 10.24.98.3
        VLAN: FFD
Payload IPs :
	Network Interfaces:
		Id: 1, 
		Backplane: Base2, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:cf:0e:ca
		IP Source: static


		Id: 2, 
		Backplane: Fabric1p1, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:cf:0e:cb
		IP Source: static


		Id: 3, 
		Backplane: Fabric2p2, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:cf:0e:cc
		IP Source: static


	Network Interfaces:
		Id: 1, 
		Backplane: Base1, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:cf:0e:cd
		IP Source: static


		Id: 2, 
		Backplane: Fabric1p2, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:cf:0e:ce
		IP Source: static


		Id: 3, 
		Backplane: Fabric2p1, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:cf:0e:cf
		IP Source: static

================================

*******************************
Original JSON string
*******************************
{ "name": "Platform #1", "number": "1", "chassis": "ms2900", "health": "Green", "fans":[ {"number": "1", "name": "Fan 1", "type": "fan", "health": "Green", "rpm": "8008","alarm": {"alarmlevel": "None"}, "LedIdentify": {"status": "off"}, "hotswapStatus":{"state": "M4", "text": "Active"}}, {"number": "2", "name": "Fan 2", "type": "fan", "health": "Green", "rpm": "8239","alarm": {"alarmlevel": "None"}, "LedIdentify": {"status": "off"}, "hotswapStatus":{"state": "M4", "text": "Active"}}, {"number": "3", "name": "Fan 3", "type": "fan", "health": "Green", "rpm": "8085","alarm": {"alarmlevel": "None"}, "LedIdentify": {"status": "off"}, "hotswapStatus":{"state": "M4", "text": "Active"}}, {"number": "4", "name": "Fan 4", "type": "fan", "health": "Green", "rpm": "8316","alarm": {"alarmlevel": "None"}, "LedIdentify": {"status": "off"}, "hotswapStatus":{"state": "M4", "text": "Active"}}, {"number": "5", "name": "Fan 5", "type": "fan", "health": "Green", "rpm": "8085","alarm": {"alarmlevel": "None"}, "LedIdentify": {"status": "off"}, "hotswapStatus":{"state": "M4", "text": "Active"}} ], "type": "platform", "components": [{"number": "10", "name": "HubNode 1", "health": "Green", "fruInfo": {"mfgDate": "Thu Oct 18 15:28:00 2018", "boardMfg": "Kontron", "boardProductName": "MSH8900", "boardProductPart": "T4301X_2-X", "boardSerialNumber": "9017009215"},"hotswapStatus":{"state": "M4", "text": "Active"},"type":"hubnode", "HubNodeFeatures":{"SwitchSpeedSupport": "1", "PortModeSupport": "0"}, "versions" : [{ "name" : "BMC", "major" : "3", "minor" : "16", "revision" : "09289D46"},{ "name" : "FPGA", "major" : "2", "minor" : "06", "revision" : "00000000"}],"model": "MSH8900", "isUpdating" : "0", "managementIP": "10.24.98.76", "managementMAC": "00:a0:a5:cf:0e:3d", "alarm": {"alarmlevel": "None", "sensors":[]}, "LedIdentify": {"status": "off"}, "components": [{ "description": "Switch 1", "number": "1", "hotswapStatus":{"state": "M4", "text": "Active"}, "networkInterfaces": [{ "id": "1", "backplane": "Unknown", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:cf:0e:3d"}]}], "status": "Active"}, {"number": "11", "name": "HubNode 2", "health": "Green", "fruInfo": {"mfgDate": "Thu Oct 18 15:27:00 2018", "boardMfg": "Kontron", "boardProductName": "MSH8900", "boardProductPart": "T4301X_2-X", "boardSerialNumber": "9017009221"},"hotswapStatus":{"state": "M4", "text": "Active"},"type":"hubnode", "HubNodeFeatures":{"SwitchSpeedSupport": "1", "PortModeSupport": "0"}, "versions" : [{ "name" : "BMC", "major" : "3", "minor" : "16", "revision" : "09289D46"},{ "name" : "FPGA", "major" : "2", "minor" : "06", "revision" : "00000000"}],"model": "MSH8900", "isUpdating" : "0", "managementIP": "10.24.98.75", "managementMAC": "00:a0:a5:cf:0e:b1", "alarm": {"alarmlevel": "None", "sensors":[]}, "LedIdentify": {"status": "off"}, "components": [{ "description": "Switch 2", "number": "1", "hotswapStatus":{"state": "M4", "text": "Active"}, "networkInterfaces": [{ "id": "1", "backplane": "Unknown", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:cf:0e:b1"}]}], "status": "Standby"}, {"number": "1", "name": "Node 1", "health": "Green", "fruInfo": {"mfgDate": "Wed Oct 17 13:32:00 2018", "boardMfg": "Kontron", "boardProductName": "4009", "boardProductPart": "1062-0224", "boardSerialNumber": "9017009621"},"hotswapStatus":{"state": "M4", "text": "Active"},"type":"node", "versions" : [{ "name" : "BMC", "major" : "1", "minor" : "03", "revision" : "091805DF"},{ "name" : "FPGA", "major" : "1", "minor" : "00", "revision" : "00000000"},{ "name" : "BIOS", "major" : "1", "minor" : "01", "revision" : "0916DD5E"}],"model": "MSP805x", "isUpdating" : "0", "managementIP": "10.24.98.113", "managementMAC": "00:a0:a5:ce:65:54", "alarm": {"alarmlevel": "None", "sensors":[]}, "LedIdentify": {"status": "off"}, "components": [{ "description": "Payload1       ", "number": "1", "hotswapStatus":{"state": "M1", "text": "Inactive"}, "networkInterfaces": [{ "id": "1", "backplane": "Base2", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:ce:65:4e"}, { "id": "2", "backplane": "Fabric1p1", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:ce:65:4f"}, { "id": "3", "backplane": "Fabric2p2", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:ce:65:50"}]}, { "description": "Payload2       ", "number": "2", "hotswapStatus":{"state": "M1", "text": "Inactive"}, "networkInterfaces": [{ "id": "1", "backplane": "Base1", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:ce:65:51"}, { "id": "2", "backplane": "Fabric1p2", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:ce:65:52"}, { "id": "3", "backplane": "Fabric2p1", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:ce:65:53"}]}] }, {"number": "2", "name": "Node 2", "health": "Green", "fruInfo": {"mfgDate": "Mon May  4 16:51:00 2020", "boardMfg": "Kontron", "boardProductName": "4009", "boardProductPart": "1062-0224", "boardSerialNumber": "9017048215"},"hotswapStatus":{"state": "M4", "text": "Active"},"type":"node", "versions" : [{ "name" : "BMC", "major" : "1", "minor" : "06", "revision" : "09289DBB"},{ "name" : "FPGA", "major" : "1", "minor" : "00", "revision" : "00000000"},{ "name" : "BIOS", "major" : "1", "minor" : "05", "revision" : "0926BD66"}],"model": "MSP805x", "isUpdating" : "0", "managementIP": "10.24.98.180", "managementMAC": "00:a0:a5:db:ea:f2", "alarm": {"alarmlevel": "None", "sensors":[]}, "LedIdentify": {"status": "off"}, "components": [{ "description": "Payload1       ", "number": "1", "hotswapStatus":{"state": "M1", "text": "Inactive"}, "networkInterfaces": [{ "id": "1", "backplane": "Base2", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:db:ea:ec"}, { "id": "2", "backplane": "Fabric1p1", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:db:ea:ed"}, { "id": "3", "backplane": "Fabric2p2", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:db:ea:ee"}]}, { "description": "Payload2       ", "number": "2", "hotswapStatus":{"state": "M1", "text": "Inactive"}, "networkInterfaces": [{ "id": "1", "backplane": "Base1", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:db:ea:ef"}, { "id": "2", "backplane": "Fabric1p2", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:db:ea:f0"}, { "id": "3", "backplane": "Fabric2p1", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:db:ea:f1"}]}] }, {"number": "3", "name": "Node 3", "health": "Green", "fruInfo": {"mfgDate": "Wed Oct 17 13:31:00 2018", "boardMfg": "Kontron", "boardProductName": "4009", "boardProductPart": "1062-0224", "boardSerialNumber": "9017009422"},"hotswapStatus":{"state": "M4", "text": "Active"},"type":"node", "versions" : [{ "name" : "BMC", "major" : "1", "minor" : "03", "revision" : "091805DF"},{ "name" : "FPGA", "major" : "1", "minor" : "00", "revision" : "00000000"},{ "name" : "BIOS", "major" : "1", "minor" : "01", "revision" : "0916DD5E"}],"model": "MSP805x", "isUpdating" : "0", "managementIP": "10.24.98.186", "managementMAC": "00:a0:a5:ce:65:bc", "alarm": {"alarmlevel": "None", "sensors":[]}, "LedIdentify": {"status": "off"}, "components": [{ "description": "Payload1       ", "number": "1", "hotswapStatus":{"state": "M1", "text": "Inactive"}, "networkInterfaces": [{ "id": "1", "backplane": "Base2", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:ce:65:b6"}, { "id": "2", "backplane": "Fabric1p1", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:ce:65:b7"}, { "id": "3", "backplane": "Fabric2p2", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:ce:65:b8"}]}, { "description": "Payload2       ", "number": "2", "hotswapStatus":{"state": "M1", "text": "Inactive"}, "networkInterfaces": [{ "id": "1", "backplane": "Base1", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:ce:65:b9"}, { "id": "2", "backplane": "Fabric1p2", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:ce:65:ba"}, { "id": "3", "backplane": "Fabric2p1", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:ce:65:bb"}]}] }, {"number": "4", "name": "Node 4", "health": "Green", "fruInfo": {"mfgDate": "Wed Oct 17 12:28:00 2018", "boardMfg": "Kontron", "boardProductName": "4009", "boardProductPart": "1062-0224", "boardSerialNumber": "9017009562"},"hotswapStatus":{"state": "M4", "text": "Active"},"type":"node", "versions" : [{ "name" : "BMC", "major" : "1", "minor" : "03", "revision" : "091805DF"},{ "name" : "FPGA", "major" : "1", "minor" : "00", "revision" : "00000000"},{ "name" : "BIOS", "major" : "1", "minor" : "01", "revision" : "0916DD5E"}],"model": "MSP805x", "isUpdating" : "0", "managementIP": "10.24.98.73", "managementMAC": "00:a0:a5:cf:0e:c0", "alarm": {"alarmlevel": "None", "sensors":[]}, "LedIdentify": {"status": "off"}, "components": [{ "description": "Payload1       ", "number": "1", "hotswapStatus":{"state": "M1", "text": "Inactive"}, "networkInterfaces": [{ "id": "1", "backplane": "Base2", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:cf:0e:ba"}, { "id": "2", "backplane": "Fabric1p1", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:cf:0e:bb"}, { "id": "3", "backplane": "Fabric2p2", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:cf:0e:bc"}]}, { "description": "Payload2       ", "number": "2", "hotswapStatus":{"state": "M1", "text": "Inactive"}, "networkInterfaces": [{ "id": "1", "backplane": "Base1", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:cf:0e:bd"}, { "id": "2", "backplane": "Fabric1p2", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:cf:0e:be"}, { "id": "3", "backplane": "Fabric2p1", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:cf:0e:bf"}]}] }, {"number": "5", "name": "Node 5", "health": "Green", "fruInfo": {"mfgDate": "Wed Oct 17 12:27:00 2018", "boardMfg": "Kontron", "boardProductName": "4009", "boardProductPart": "1062-0224", "boardSerialNumber": "9017009525"},"hotswapStatus":{"state": "M4", "text": "Active"},"type":"node", "versions" : [{ "name" : "BMC", "major" : "1", "minor" : "03", "revision" : "091805DF"},{ "name" : "FPGA", "major" : "1", "minor" : "00", "revision" : "00000000"},{ "name" : "BIOS", "major" : "1", "minor" : "01", "revision" : "0916DD5E"}],"model": "MSP805x", "isUpdating" : "0", "managementIP": "10.24.98.104", "managementMAC": "00:a0:a5:cf:0f:a8", "alarm": {"alarmlevel": "None", "sensors":[]}, "LedIdentify": {"status": "off"}, "components": [{ "description": "Payload1       ", "number": "1", "hotswapStatus":{"state": "M1", "text": "Inactive"}, "networkInterfaces": [{ "id": "1", "backplane": "Base2", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:cf:0f:a2"}, { "id": "2", "backplane": "Fabric1p1", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:cf:0f:a3"}, { "id": "3", "backplane": "Fabric2p2", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:cf:0f:a4"}]}, { "description": "Payload2       ", "number": "2", "hotswapStatus":{"state": "M1", "text": "Inactive"}, "networkInterfaces": [{ "id": "1", "backplane": "Base1", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:cf:0f:a5"}, { "id": "2", "backplane": "Fabric1p2", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:cf:0f:a6"}, { "id": "3", "backplane": "Fabric2p1", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:cf:0f:a7"}]}] }, {"number": "6", "name": "Node 6", "health": "Green", "fruInfo": {"mfgDate": "Wed Oct 17 13:30:00 2018", "boardMfg": "Kontron", "boardProductName": "4009", "boardProductPart": "1062-0224", "boardSerialNumber": "9017009296"},"hotswapStatus":{"state": "M4", "text": "Active"},"type":"node", "versions" : [{ "name" : "BMC", "major" : "1", "minor" : "03", "revision" : "091805DF"},{ "name" : "FPGA", "major" : "1", "minor" : "00", "revision" : "00000000"},{ "name" : "BIOS", "major" : "1", "minor" : "01", "revision" : "0916DD5E"}],"model": "MSP805x", "isUpdating" : "0", "managementIP": "10.24.98.54", "managementMAC": "00:a0:a5:ce:63:9c", "alarm": {"alarmlevel": "None", "sensors":[]}, "LedIdentify": {"status": "off"}, "components": [{ "description": "Payload1       ", "number": "1", "hotswapStatus":{"state": "M1", "text": "Inactive"}, "networkInterfaces": [{ "id": "1", "backplane": "Base2", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:ce:63:96"}, { "id": "2", "backplane": "Fabric1p1", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:ce:63:97"}, { "id": "3", "backplane": "Fabric2p2", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:ce:63:98"}]}, { "description": "Payload2       ", "number": "2", "hotswapStatus":{"state": "M1", "text": "Inactive"}, "networkInterfaces": [{ "id": "1", "backplane": "Base1", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:ce:63:99"}, { "id": "2", "backplane": "Fabric1p2", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:ce:63:9a"}, { "id": "3", "backplane": "Fabric2p1", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:ce:63:9b"}]}] }, {"number": "7", "name": "Node 7", "health": "Green", "fruInfo": {"mfgDate": "Wed Oct 17 15:24:00 2018", "boardMfg": "Kontron", "boardProductName": "4009", "boardProductPart": "1062-0224", "boardSerialNumber": "9017009325"},"hotswapStatus":{"state": "M4", "text": "Active"},"type":"node", "versions" : [{ "name" : "BMC", "major" : "1", "minor" : "03", "revision" : "091805DF"},{ "name" : "FPGA", "major" : "1", "minor" : "00", "revision" : "00000000"},{ "name" : "BIOS", "major" : "1", "minor" : "01", "revision" : "0916DD5E"}],"model": "MSP805x", "isUpdating" : "0", "managementIP": "10.24.98.145", "managementMAC": "00:a0:a5:cf:0f:8c", "alarm": {"alarmlevel": "None", "sensors":[]}, "LedIdentify": {"status": "off"}, "components": [{ "description": "Payload1       ", "number": "1", "hotswapStatus":{"state": "M1", "text": "Inactive"}, "networkInterfaces": [{ "id": "1", "backplane": "Base2", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:cf:0f:86"}, { "id": "2", "backplane": "Fabric1p1", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:cf:0f:87"}, { "id": "3", "backplane": "Fabric2p2", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:cf:0f:88"}]}, { "description": "Payload2       ", "number": "2", "hotswapStatus":{"state": "M1", "text": "Inactive"}, "networkInterfaces": [{ "id": "1", "backplane": "Base1", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:cf:0f:89"}, { "id": "2", "backplane": "Fabric1p2", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:cf:0f:8a"}, { "id": "3", "backplane": "Fabric2p1", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:cf:0f:8b"}]}] }, {"number": "8", "name": "Node 8", "health": "Green", "fruInfo": {"mfgDate": "Wed Oct 17 15:24:00 2018", "boardMfg": "Kontron", "boardProductName": "4009", "boardProductPart": "1062-0224", "boardSerialNumber": "9017009496"},"hotswapStatus":{"state": "M4", "text": "Active"},"type":"node", "versions" : [{ "name" : "BMC", "major" : "1", "minor" : "03", "revision" : "091805DF"},{ "name" : "FPGA", "major" : "1", "minor" : "00", "revision" : "00000000"},{ "name" : "BIOS", "major" : "1", "minor" : "01", "revision" : "0916DD5E"}],"model": "MSP805x", "isUpdating" : "0", "managementIP": "10.24.98.160", "managementMAC": "00:a0:a5:cf:0f:84", "alarm": {"alarmlevel": "None", "sensors":[]}, "LedIdentify": {"status": "off"}, "components": [{ "description": "Payload1       ", "number": "1", "hotswapStatus":{"state": "M1", "text": "Inactive"}, "networkInterfaces": [{ "id": "1", "backplane": "Base2", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:cf:0f:7e"}, { "id": "2", "backplane": "Fabric1p1", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:cf:0f:7f"}, { "id": "3", "backplane": "Fabric2p2", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:cf:0f:80"}]}, { "description": "Payload2       ", "number": "2", "hotswapStatus":{"state": "M1", "text": "Inactive"}, "networkInterfaces": [{ "id": "1", "backplane": "Base1", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:cf:0f:81"}, { "id": "2", "backplane": "Fabric1p2", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:cf:0f:82"}, { "id": "3", "backplane": "Fabric2p1", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:cf:0f:83"}]}] }, {"number": "9", "name": "Node 9", "health": "Green", "fruInfo": {"mfgDate": "Wed Oct 17 14:14:00 2018", "boardMfg": "Kontron", "boardProductName": "4009", "boardProductPart": "1062-0224", "boardSerialNumber": "9017009585"},"hotswapStatus":{"state": "M4", "text": "Active"},"type":"node", "versions" : [{ "name" : "BMC", "major" : "1", "minor" : "03", "revision" : "091805DF"},{ "name" : "FPGA", "major" : "1", "minor" : "00", "revision" : "00000000"},{ "name" : "BIOS", "major" : "1", "minor" : "01", "revision" : "0916DD5E"}],"model": "MSP805x", "isUpdating" : "0", "managementIP": "10.24.98.97", "managementMAC": "00:a0:a5:cf:0e:d0", "alarm": {"alarmlevel": "None", "sensors":[]}, "LedIdentify": {"status": "off"}, "components": [{ "description": "Payload1       ", "number": "1", "hotswapStatus":{"state": "M1", "text": "Inactive"}, "networkInterfaces": [{ "id": "1", "backplane": "Base2", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:cf:0e:ca"}, { "id": "2", "backplane": "Fabric1p1", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:cf:0e:cb"}, { "id": "3", "backplane": "Fabric2p2", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:cf:0e:cc"}]}, { "description": "Payload2       ", "number": "2", "hotswapStatus":{"state": "M1", "text": "Inactive"}, "networkInterfaces": [{ "id": "1", "backplane": "Base1", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:cf:0e:cd"}, { "id": "2", "backplane": "Fabric1p2", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:cf:0e:ce"}, { "id": "3", "backplane": "Fabric2p1", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:cf:0e:cf"}]}] }, { "name": "PSU", "components": [{"id": "PSU1", "number": "1", "name": "Power Supply 1", "health": "Green", "type": "psu", "hotswapStatus":{"state": "M4", "text": "Active"},"alarm": {"alarmlevel": "None"}, "tempInlet": "19.00", "tempOutlet": "24.00", "vIn": "206.00", "powerOut": "56", "powerScale": "1400","peakConsumption": "592", "averageConsumption": "357"},{"id": "PSU2", "number": "2", "name": "Power Supply 2", "health": "Green", "type": "psu", "hotswapStatus":{"state": "M4", "text": "Active"},"alarm": {"alarmlevel": "None"}, "tempInlet": "19.00", "tempOutlet": "24.00", "vIn": "205.00", "powerOut": "0", "powerScale": "1400","peakConsumption": "568", "averageConsumption": "340"}]}], "switchOID": {"oid": "1.3.6.1.4.1.6603"}, "alarm": {"alarmlevel": "None",  "components" : [ {"nodes" : [] } , {"psu" : [] }, {"fans" : [] }], "text": ""}, "LedIdentify": {"status": "off"}}