System informations
*******************************
Name: SYMKLOUD
chassis: ms2900
Health: Healthy
*******************************
Fans: 
*******************************
Fan 1: 
	Present :true
	Status :Healthy
	3080 RPM
Fan 2: 
	Present :true
	Status :Healthy
	3080 RPM
Fan 3: 
	Present :true
	Status :Healthy
	3157 RPM
Fan 4: 
	Present :true
	Status :Healthy
	3080 RPM
Fan 5: 
	Present :true
	Status :Healthy
	3080 RPM


*******************************
PSU: 
*******************************
Name: PSU 1
Health: Healthy
Health Details: No details available
Hotswap Status: Active
FRU: Informations are invalid

Name: PSU 2
Health: Healthy
Health Details: No details available
Hotswap Status: Active
FRU: Informations are invalid



*******************************
HubNodes
*******************************

================================
Name: HubNode 1
Health: Healthy
Health Details: 
        Node BMC sensors aggregated for Health Status:
        | Sensor ID | Sensor Name      | Value     | Health                |
         ------------------------------------------------------------------ 
        | 0x0b      | Temp On-Board    | 37.00     | Healthy               |
        | 0x0c      | Temp Eth Switch  | 37.00     | Healthy               |
        | 0x0d      | Temp Quad Phy    | 43.00     | Healthy               |
        | 0x0e      | Temp Inlet       | 27.00     | Healthy               |
        | 0x0f      | Temp Phy 10G     | 60.00     | Healthy               |
        | 0x10      | Vcc +12V In      | 12.12     | Healthy               |
        | 0x11      | Vcc +5V SUS      | 5.08      | Healthy               |
        | 0x12      | Vcc +3.3V SUS    | 3.32      | Healthy               |
        | 0x13      | Vcc +1.8V SUS    | 1.79      | Healthy               |
        | 0x14      | Vcc +1.5V SUS    | 1.50      | Healthy               |
        | 0x15      | Vcc +1.25V SUS   | 1.24      | Healthy               |
        | 0x16      | Vcc +1.2V SUS    | 1.19      | Healthy               |
        | 0x17      | Vcc +0.75V SUS   | 0.74      | Healthy               |
        | 0x18      | Vcc +3.3V        | 3.31      | Healthy               |
        | 0x19      | Vcc +2.5V        | 2.49      | Healthy               |
        | 0x1a      | Vcc +1.8V        | 1.78      | Healthy               |
        | 0x1b      | Vcc +1.2V        | 1.21      | Healthy               |
        | 0x1c      | Vcc +1.0V        | 1.01      | Healthy               |
        | 0x1d      | Vbat +3V         | 3.04      | Healthy               |
        | 0x3f      | Power Good Latch | 0x01 0x80 | Healthy               |
        | 0x40      | FPGA RW Status   | 0x02 0x80 | Healthy               |
        | 0x41      | FPGA Heartbeat   | 0x02 0x80 | Healthy               |
        | 0x48      | ShMC Redun State | 0x02 0x80 | Healthy               |
Hotswap Status: Active
Product name: MSH8900
Part number: T4301X_2-X
Serial number: 9016015618
Manufacturing date: Tue Sep 27 18:52:00 2016
Type: HubNode
Status: Active
Model: MSH8900
HPM versions:
	BMC: 3.19.09377D23
	FPGA: 2.6.00000000
Management Network:
        Management MAC: 00:a0:a5:8d:7e:b5
        IP Source: dhcp
        IP: 10.24.35.94
        Subnet: 255.255.255.0
        Gateway: 10.24.35.3
        VLAN: 4093
Payload IPs :
	Network Interfaces:
		Id: 1, 
		Backplane: Management, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:8d:7e:96
		IP Source: static

================================

================================
Name: HubNode 2
Health: Healthy
Health Details: 
        Node BMC sensors aggregated for Health Status:
        | Sensor ID | Sensor Name      | Value     | Health                |
         ------------------------------------------------------------------ 
        | 0x0b      | Temp On-Board    | 36.00     | Healthy               |
        | 0x0c      | Temp Eth Switch  | 36.00     | Healthy               |
        | 0x0d      | Temp Quad Phy    | 43.00     | Healthy               |
        | 0x0e      | Temp Inlet       | 26.00     | Healthy               |
        | 0x0f      | Temp Phy 10G     | 57.00     | Healthy               |
        | 0x10      | Vcc +12V In      | 12.18     | Healthy               |
        | 0x11      | Vcc +5V SUS      | 5.05      | Healthy               |
        | 0x12      | Vcc +3.3V SUS    | 3.32      | Healthy               |
        | 0x13      | Vcc +1.8V SUS    | 1.79      | Healthy               |
        | 0x14      | Vcc +1.5V SUS    | 1.50      | Healthy               |
        | 0x15      | Vcc +1.25V SUS   | 1.24      | Healthy               |
        | 0x16      | Vcc +1.2V SUS    | 1.19      | Healthy               |
        | 0x17      | Vcc +0.75V SUS   | 0.75      | Healthy               |
        | 0x18      | Vcc +3.3V        | 3.32      | Healthy               |
        | 0x19      | Vcc +2.5V        | 2.49      | Healthy               |
        | 0x1a      | Vcc +1.8V        | 1.79      | Healthy               |
        | 0x1b      | Vcc +1.2V        | 1.21      | Healthy               |
        | 0x1c      | Vcc +1.0V        | 1.01      | Healthy               |
        | 0x1d      | Vbat +3V         | 3.04      | Healthy               |
        | 0x3f      | Power Good Latch | 0x01 0x80 | Healthy               |
        | 0x40      | FPGA RW Status   | 0x02 0x80 | Healthy               |
        | 0x41      | FPGA Heartbeat   | 0x02 0x80 | Healthy               |
        | 0x48      | ShMC Redun State | 0x08 0x80 | Healthy               |
Hotswap Status: Active
Product name: MSH8900
Part number: T4301X_2-X
Serial number: 9016015638
Manufacturing date: Tue Sep 27 19:31:00 2016
Type: HubNode
Status: Standby
Model: MSH8900
HPM versions:
	BMC: 3.19.09377D23
	FPGA: 2.6.00000000
Management Network:
        Management MAC: 00:a0:a5:91:bf:c1
        IP Source: dhcp
        IP: 10.24.35.95
        Subnet: 255.255.255.0
        Gateway: 10.24.35.3
        VLAN: 4093
Payload IPs :
	Network Interfaces:
		Id: 1, 
		Backplane: Management, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:91:bf:a2
		IP Source: static

================================

*******************************
Nodes
*******************************

================================
SLOT #1
================================
Name: Node 1
Health: Healthy
Health Details: 
        Node BMC sensors aggregated for Health Status:
        | Sensor ID | Sensor Name      | Value     | Health                |
         ------------------------------------------------------------------ 
        | 0x0e      | Vcc +12.0V SUS   | 12.06     | Healthy               |
        | 0x0f      | Vcc +3.3V SUS    | 3.35      | Healthy               |
        | 0x10      | Vcc +1.5V SUS    | 1.51      | Healthy               |
        | 0x11      | Vcc +1.2V SUS    | 1.21      | Healthy               |
        | 0x04      | Temp Brd Inlet   | 27.00     | Healthy               |
        | 0x05      | Temp Brd Outlet  | 27.00     | Healthy               |
        | 0x07      | Temp BMC         | 30.00     | Healthy               |
        | 0x08      | Temp CPU 1       | 42.00     | Healthy               |
        | 0x09      | Temp CPU 2       | 33.00     | Healthy               |
        Payload Specific Health Status (for Nodes with more than 1 payload/mmc):
            Payload 1: Healthy
            Payload 2: Healthy

Hotswap Status: Active
Product name: 4005
Part number: T4005CXXX_2-CXX
Serial number: 9013144735
Manufacturing date: Tue Sep 20 17:24:00 2016
Type: Node
Model: MSP8022
HPM versions:
	BMC: 2.20.09363399
	FPGA: 3.0.00000000
	BIOS: 2.20.0926E48B
Management Network:
        Management MAC: 00:a0:a5:8d:6b:c4
        IP Source: dhcp
        IP: 10.24.35.96
        Subnet: 255.255.255.0
        Gateway: 10.24.35.3
        VLAN: 4093
Payload IPs :
	Network Interfaces:
		Id: 1, 
		Backplane: Base2, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:8d:6b:c0
		IP Source: static


		Id: 2, 
		Backplane: Fabric1, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:8d:6b:c1
		IP Source: static


	Network Interfaces:
		Id: 1, 
		Backplane: Base1, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:8d:6b:c2
		IP Source: static


		Id: 2, 
		Backplane: Fabric2, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:8d:6b:c3
		IP Source: static

================================

================================
SLOT #2
================================
Name: Node 2
Health: Healthy
Health Details: 
        Node BMC sensors aggregated for Health Status:
        | Sensor ID | Sensor Name      | Value     | Health                |
         ------------------------------------------------------------------ 
        | 0x0e      | Vcc +12.0V SUS   | 12.18     | Healthy               |
        | 0x0f      | Vcc +3.3V SUS    | 3.34      | Healthy               |
        | 0x10      | Vcc +1.5V SUS    | 1.50      | Healthy               |
        | 0x11      | Vcc +1.2V SUS    | 1.21      | Healthy               |
        | 0x04      | Temp Brd Inlet   | 27.00     | Healthy               |
        | 0x05      | Temp Brd Outlet  | 27.00     | Healthy               |
        | 0x07      | Temp BMC         | 30.00     | Healthy               |
        | 0x08      | Temp CPU 1       | 0.00      | Healthy               |
        | 0x09      | Temp CPU 2       | 33.00     | Healthy               |
        Payload Specific Health Status (for Nodes with more than 1 payload/mmc):
            Payload 1: Healthy
            Payload 2: Healthy

Hotswap Status: Active
Product name: 4005
Part number: T4005CXXX_2-CXX
Serial number: 9013144599
Manufacturing date: Tue Sep 20 18:06:00 2016
Type: Node
Model: MSP8022
HPM versions:
	BMC: 2.20.09363399
	FPGA: 3.0.00000000
	BIOS: 2.20.0926E48B
Management Network:
        Management MAC: 00:a0:a5:8d:65:1a
        IP Source: dhcp
        IP: 10.24.35.97
        Subnet: 255.255.255.0
        Gateway: 10.24.35.3
        VLAN: 4093
Payload IPs :
	Network Interfaces:
		Id: 1, 
		Backplane: Base2, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:8d:65:16
		IP Source: static


		Id: 2, 
		Backplane: Fabric1, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:8d:65:17
		IP Source: static


	Network Interfaces:
		Id: 1, 
		Backplane: Base1, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:8d:65:18
		IP Source: static


		Id: 2, 
		Backplane: Fabric2, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:8d:65:19
		IP Source: static

================================

================================
SLOT #3
================================
Name: Node 3
Health: Healthy
Health Details: 
        Node BMC sensors aggregated for Health Status:
        | Sensor ID | Sensor Name      | Value     | Health                |
         ------------------------------------------------------------------ 
        | 0x0e      | Vcc +12.0V SUS   | 12.06     | Healthy               |
        | 0x0f      | Vcc +3.3V SUS    | 3.34      | Healthy               |
        | 0x10      | Vcc +1.5V SUS    | 1.50      | Healthy               |
        | 0x11      | Vcc +1.2V SUS    | 1.21      | Healthy               |
        | 0x04      | Temp Brd Inlet   | 27.00     | Healthy               |
        | 0x05      | Temp Brd Outlet  | 28.00     | Healthy               |
        | 0x07      | Temp BMC         | 30.00     | Healthy               |
        | 0x08      | Temp CPU 1       | 0.00      | Healthy               |
        | 0x09      | Temp CPU 2       | 33.00     | Healthy               |
        Payload Specific Health Status (for Nodes with more than 1 payload/mmc):
            Payload 1: Healthy
            Payload 2: Healthy

Hotswap Status: Active
Product name: 4005
Part number: T4005CXXX_2-CXX
Serial number: 9013144326
Manufacturing date: Tue Sep 20 17:58:00 2016
Type: Node
Model: MSP8022
HPM versions:
	BMC: 2.20.09363399
	FPGA: 3.0.00000000
	BIOS: 2.20.0926E48B
Management Network:
        Management MAC: 00:a0:a5:91:aa:7a
        IP Source: dhcp
        IP: 10.24.35.98
        Subnet: 255.255.255.0
        Gateway: 10.24.35.3
        VLAN: 4093
Payload IPs :
	Network Interfaces:
		Id: 1, 
		Backplane: Base2, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:91:aa:76
		IP Source: static


		Id: 2, 
		Backplane: Fabric1, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:91:aa:77
		IP Source: static


	Network Interfaces:
		Id: 1, 
		Backplane: Base1, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:91:aa:78
		IP Source: static


		Id: 2, 
		Backplane: Fabric2, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:91:aa:79
		IP Source: static

================================

================================
SLOT #4
================================
Name: Node 4
Health: Healthy
Health Details: 
        Node BMC sensors aggregated for Health Status:
        | Sensor ID | Sensor Name      | Value     | Health                |
         ------------------------------------------------------------------ 
        | 0x0e      | Vcc +12.0V SUS   | 12.12     | Healthy               |
        | 0x0f      | Vcc +3.3V SUS    | 3.35      | Healthy               |
        | 0x10      | Vcc +1.5V SUS    | 1.51      | Healthy               |
        | 0x11      | Vcc +1.2V SUS    | 1.19      | Healthy               |
        | 0x04      | Temp Brd Inlet   | 25.00     | Healthy               |
        | 0x05      | Temp Brd Outlet  | 27.00     | Healthy               |
        | 0x07      | Temp BMC         | 29.00     | Healthy               |
        | 0x08      | Temp CPU 1       | 43.00     | Healthy               |
        | 0x09      | Temp CPU 2       | 34.00     | Healthy               |
        Payload Specific Health Status (for Nodes with more than 1 payload/mmc):
            Payload 1: Healthy
            Payload 2: Healthy

Hotswap Status: Active
Product name: 4005
Part number: T4005CXXX_2-CXX
Serial number: 9013144812
Manufacturing date: Tue Sep 20 18:07:00 2016
Type: Node
Model: MSP8022
HPM versions:
	BMC: 2.20.09363399
	FPGA: 3.0.00000000
	BIOS: 2.20.0926E48B
Management Network:
        Management MAC: 00:a0:a5:8d:67:be
        IP Source: dhcp
        IP: 10.24.35.99
        Subnet: 255.255.255.0
        Gateway: 10.24.35.3
        VLAN: 4093
Payload IPs :
	Network Interfaces:
		Id: 1, 
		Backplane: Base2, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:8d:67:ba
		IP Source: static


		Id: 2, 
		Backplane: Fabric1, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:8d:67:bb
		IP Source: static


	Network Interfaces:
		Id: 1, 
		Backplane: Base1, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:8d:67:bc
		IP Source: static


		Id: 2, 
		Backplane: Fabric2, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:8d:67:bd
		IP Source: static

================================

================================
SLOT #5
================================
Name: Node 5
Health: Healthy
Health Details: 
        Node BMC sensors aggregated for Health Status:
        | Sensor ID | Sensor Name      | Value     | Health                |
         ------------------------------------------------------------------ 
        | 0x0e      | Vcc +12.0V SUS   | 12.18     | Healthy               |
        | 0x0f      | Vcc +3.3V SUS    | 3.34      | Healthy               |
        | 0x10      | Vcc +1.5V SUS    | 1.50      | Healthy               |
        | 0x11      | Vcc +1.2V SUS    | 1.21      | Healthy               |
        | 0x04      | Temp Brd Inlet   | 25.00     | Healthy               |
        | 0x05      | Temp Brd Outlet  | 27.00     | Healthy               |
        | 0x07      | Temp BMC         | 29.00     | Healthy               |
        | 0x08      | Temp CPU 1       | 41.00     | Healthy               |
        | 0x09      | Temp CPU 2       | 35.00     | Healthy               |
        Payload Specific Health Status (for Nodes with more than 1 payload/mmc):
            Payload 1: Healthy
            Payload 2: Healthy

Hotswap Status: Active
Product name: 4005
Part number: T4005CXXX_2-CXX
Serial number: 9013144351
Manufacturing date: Tue Sep 20 17:58:00 2016
Type: Node
Model: MSP8022
HPM versions:
	BMC: 2.20.09363399
	FPGA: 3.0.00000000
	BIOS: 2.20.0926E48B
Management Network:
        Management MAC: 00:a0:a5:91:aa:c8
        IP Source: dhcp
        IP: 10.24.35.100
        Subnet: 255.255.255.0
        Gateway: 10.24.35.3
        VLAN: 4093
Payload IPs :
	Network Interfaces:
		Id: 1, 
		Backplane: Base2, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:91:aa:c4
		IP Source: static


		Id: 2, 
		Backplane: Fabric1, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:91:aa:c5
		IP Source: static


	Network Interfaces:
		Id: 1, 
		Backplane: Base1, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:91:aa:c6
		IP Source: static


		Id: 2, 
		Backplane: Fabric2, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:91:aa:c7
		IP Source: static

================================

================================
SLOT #6
================================
Name: Node 6
Health: Healthy
Health Details: 
        Node BMC sensors aggregated for Health Status:
        | Sensor ID | Sensor Name      | Value     | Health                |
         ------------------------------------------------------------------ 
        | 0x0e      | Vcc +12.0V SUS   | 12.18     | Healthy               |
        | 0x0f      | Vcc +3.3V SUS    | 3.34      | Healthy               |
        | 0x10      | Vcc +1.5V SUS    | 1.49      | Healthy               |
        | 0x11      | Vcc +1.2V SUS    | 1.21      | Healthy               |
        | 0x04      | Temp Brd Inlet   | 26.00     | Healthy               |
        | 0x05      | Temp Brd Outlet  | 28.00     | Healthy               |
        | 0x07      | Temp BMC         | 29.00     | Healthy               |
        | 0x08      | Temp CPU 1       | 0.00      | Healthy               |
        | 0x09      | Temp CPU 2       | 0.00      | Healthy               |
        Payload Specific Health Status (for Nodes with more than 1 payload/mmc):
            Payload 1: Invalid Health Status
            Payload 2: Invalid Health Status

Hotswap Status: Active
Product name: 4005
Part number: T4005CXXX_2-CXX
Serial number: 9017048946
Manufacturing date: Thu Apr 23 17:32:00 2020
Type: Node
Model: MSP8022
HPM versions:
	BMC: 2.18.08FA45E0
	FPGA: 2.12.00000000
	BIOS: 2.14.00000000
Management Network:
        Management MAC: 00:a0:a5:dc:37:9c
        IP Source: dhcp
        IP: 10.24.35.171
        Subnet: 255.255.255.0
        Gateway: 10.24.35.3
        VLAN: 4093
Payload IPs :
	Network Interfaces:
		Id: 1, 
		Backplane: Base2, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:dc:37:98
		IP Source: static


		Id: 2, 
		Backplane: Fabric1, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:dc:37:99
		IP Source: static


	Network Interfaces:
		Id: 1, 
		Backplane: Base1, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:dc:37:9a
		IP Source: static


		Id: 2, 
		Backplane: Fabric2, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:dc:37:9b
		IP Source: static

================================

================================
SLOT #7
================================
Name: Node 7
Health: Healthy
Health Details: 
        Node BMC sensors aggregated for Health Status:
        | Sensor ID | Sensor Name      | Value     | Health                |
         ------------------------------------------------------------------ 
        | 0x0e      | Vcc +12.0V SUS   | 12.06     | Healthy               |
        | 0x0f      | Vcc +3.3V SUS    | 3.34      | Healthy               |
        | 0x10      | Vcc +1.5V SUS    | 1.50      | Healthy               |
        | 0x11      | Vcc +1.2V SUS    | 1.21      | Healthy               |
        | 0x04      | Temp Brd Inlet   | 25.00     | Healthy               |
        | 0x05      | Temp Brd Outlet  | 26.00     | Healthy               |
        | 0x07      | Temp BMC         | 29.00     | Healthy               |
        | 0x08      | Temp CPU 1       | 42.00     | Healthy               |
        | 0x09      | Temp CPU 2       | 36.00     | Healthy               |
        Payload Specific Health Status (for Nodes with more than 1 payload/mmc):
            Payload 1: Healthy
            Payload 2: Healthy

Hotswap Status: Active
Product name: 4005
Part number: T4005CXXX_2-CXX
Serial number: 9013144644
Manufacturing date: Tue Sep 20 18:07:00 2016
Type: Node
Model: MSP8022
HPM versions:
	BMC: 2.20.09363399
	FPGA: 3.0.00000000
	BIOS: 2.20.0926E48B
Management Network:
        Management MAC: 00:a0:a5:8d:66:e6
        IP Source: dhcp
        IP: 10.24.35.102
        Subnet: 255.255.255.0
        Gateway: 10.24.35.3
        VLAN: 4093
Payload IPs :
	Network Interfaces:
		Id: 1, 
		Backplane: Base2, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:8d:66:e2
		IP Source: static


		Id: 2, 
		Backplane: Fabric1, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:8d:66:e3
		IP Source: static


	Network Interfaces:
		Id: 1, 
		Backplane: Base1, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:8d:66:e4
		IP Source: static


		Id: 2, 
		Backplane: Fabric2, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:8d:66:e5
		IP Source: static

================================

================================
SLOT #8
================================
Name: Node 8
Health: Healthy
Health Details: 
        Node BMC sensors aggregated for Health Status:
        | Sensor ID | Sensor Name      | Value     | Health                |
         ------------------------------------------------------------------ 
        | 0x0e      | Vcc +12.0V SUS   | 12.18     | Healthy               |
        | 0x0f      | Vcc +3.3V SUS    | 3.34      | Healthy               |
        | 0x10      | Vcc +1.5V SUS    | 1.50      | Healthy               |
        | 0x11      | Vcc +1.2V SUS    | 1.21      | Healthy               |
        | 0x04      | Temp Brd Inlet   | 25.00     | Healthy               |
        | 0x05      | Temp Brd Outlet  | 27.00     | Healthy               |
        | 0x07      | Temp BMC         | 29.00     | Healthy               |
        | 0x08      | Temp CPU 1       | 40.00     | Healthy               |
        | 0x09      | Temp CPU 2       | 35.00     | Healthy               |
        Payload Specific Health Status (for Nodes with more than 1 payload/mmc):
            Payload 1: Healthy
            Payload 2: Healthy

Hotswap Status: Active
Product name: 4005
Part number: T4005CXXX_2-CXX
Serial number: 9013144711
Manufacturing date: Tue Sep 20 18:11:00 2016
Type: Node
Model: MSP8022
HPM versions:
	BMC: 2.20.09363399
	FPGA: 3.0.00000000
	BIOS: 2.20.0926E48B
Management Network:
        Management MAC: 00:a0:a5:91:b2:0e
        IP Source: dhcp
        IP: 10.24.35.103
        Subnet: 255.255.255.0
        Gateway: 10.24.35.3
        VLAN: 4093
Payload IPs :
	Network Interfaces:
		Id: 1, 
		Backplane: Base2, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:91:b2:0a
		IP Source: static


		Id: 2, 
		Backplane: Fabric1, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:91:b2:0b
		IP Source: static


	Network Interfaces:
		Id: 1, 
		Backplane: Base1, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:91:b2:0c
		IP Source: static


		Id: 2, 
		Backplane: Fabric2, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:91:b2:0d
		IP Source: static

================================

================================
SLOT #9
================================
Name: Node 9
Health: Healthy
Health Details: 
        Node BMC sensors aggregated for Health Status:
        | Sensor ID | Sensor Name      | Value     | Health                |
         ------------------------------------------------------------------ 
        | 0x0e      | Vcc +12.0V SUS   | 12.18     | Healthy               |
        | 0x0f      | Vcc +3.3V SUS    | 3.34      | Healthy               |
        | 0x10      | Vcc +1.5V SUS    | 1.49      | Healthy               |
        | 0x11      | Vcc +1.2V SUS    | 1.19      | Healthy               |
        | 0x04      | Temp Brd Inlet   | 26.00     | Healthy               |
        | 0x05      | Temp Brd Outlet  | 27.00     | Healthy               |
        | 0x07      | Temp BMC         | 29.00     | Healthy               |
        | 0x08      | Temp CPU 1       | 42.00     | Healthy               |
        | 0x09      | Temp CPU 2       | 36.00     | Healthy               |
        Payload Specific Health Status (for Nodes with more than 1 payload/mmc):
            Payload 1: Healthy
            Payload 2: Healthy

Hotswap Status: Active
Product name: 4005
Part number: T4005CXXX_2-CXX
Serial number: 9013144455
Manufacturing date: Tue Sep 20 17:58:00 2016
Type: Node
Model: MSP8022
HPM versions:
	BMC: 2.20.09363399
	FPGA: 3.0.00000000
	BIOS: 2.20.0926E48B
Management Network:
        Management MAC: 00:a0:a5:91:aa:bc
        IP Source: dhcp
        IP: 10.24.35.104
        Subnet: 255.255.255.0
        Gateway: 10.24.35.3
        VLAN: 4093
Payload IPs :
	Network Interfaces:
		Id: 1, 
		Backplane: Base2, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:91:aa:b8
		IP Source: static


		Id: 2, 
		Backplane: Fabric1, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:91:aa:b9
		IP Source: static


	Network Interfaces:
		Id: 1, 
		Backplane: Base1, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:91:aa:ba
		IP Source: static


		Id: 2, 
		Backplane: Fabric2, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:91:aa:bb
		IP Source: static

================================

*******************************
Original JSON string
*******************************
{ "name": "Platform #1", "number": "1", "chassis": "ms2900", "health": "Green", "fans":[ {"number": "1", "name": "Fan 1", "type": "fan", "health": "Green", "rpm": "3080","alarm": {"alarmlevel": "None"}, "LedIdentify": {"status": "off"}, "hotswapStatus":{"state": "M4", "text": "Active"}}, {"number": "2", "name": "Fan 2", "type": "fan", "health": "Green", "rpm": "3080","alarm": {"alarmlevel": "None"}, "LedIdentify": {"status": "off"}, "hotswapStatus":{"state": "M4", "text": "Active"}}, {"number": "3", "name": "Fan 3", "type": "fan", "health": "Green", "rpm": "3157","alarm": {"alarmlevel": "None"}, "LedIdentify": {"status": "off"}, "hotswapStatus":{"state": "M4", "text": "Active"}}, {"number": "4", "name": "Fan 4", "type": "fan", "health": "Green", "rpm": "3080","alarm": {"alarmlevel": "None"}, "LedIdentify": {"status": "off"}, "hotswapStatus":{"state": "M4", "text": "Active"}}, {"number": "5", "name": "Fan 5", "type": "fan", "health": "Green", "rpm": "3157","alarm": {"alarmlevel": "None"}, "LedIdentify": {"status": "off"}, "hotswapStatus":{"state": "M4", "text": "Active"}} ], "type": "platform", "components": [{"number": "10", "name": "HubNode 1", "health": "Green", "fruInfo": {"mfgDate": "Tue Sep 27 18:52:00 2016", "boardMfg": "Kontron", "boardProductName": "MSH8900", "boardProductPart": "T4301X_2-X", "boardSerialNumber": "9016015618"},"hotswapStatus":{"state": "M4", "text": "Active"},"type":"hubnode", "HubNodeFeatures":{"SwitchSpeedSupport": "1", "PortModeSupport": "0"}, "versions" : [{ "name" : "BMC", "major" : "3", "minor" : "19", "revision" : "09377D23"},{ "name" : "FPGA", "major" : "2", "minor" : "06", "revision" : "00000000"}],"model": "MSH8900", "isUpdating" : "0", "managementIP": "10.24.35.94", "managementMAC": "00:a0:a5:8d:7e:b5", "alarm": {"alarmlevel": "None", "sensors":[]}, "LedIdentify": {"status": "off"}, "components": [{ "description": "Switch 1", "number": "1", "hotswapStatus":{"state": "M4", "text": "Active"}, "health": "Green", "networkInterfaces": [{ "id": "1", "backplane": "Management", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:8d:7e:96"}]}], "status": "Active"}, {"number": "11", "name": "HubNode 2", "health": "Green", "fruInfo": {"mfgDate": "Tue Sep 27 19:31:00 2016", "boardMfg": "Kontron", "boardProductName": "MSH8900", "boardProductPart": "T4301X_2-X", "boardSerialNumber": "9016015638"},"hotswapStatus":{"state": "M4", "text": "Active"},"type":"hubnode", "HubNodeFeatures":{"SwitchSpeedSupport": "1", "PortModeSupport": "0"}, "versions" : [{ "name" : "BMC", "major" : "3", "minor" : "19", "revision" : "09377D23"},{ "name" : "FPGA", "major" : "2", "minor" : "06", "revision" : "00000000"}],"model": "MSH8900", "isUpdating" : "0", "managementIP": "10.24.35.95", "managementMAC": "00:a0:a5:91:bf:c1", "alarm": {"alarmlevel": "None", "sensors":[]}, "LedIdentify": {"status": "off"}, "components": [{ "description": "Switch 2", "number": "1", "hotswapStatus":{"state": "M4", "text": "Active"}, "health": "Green", "networkInterfaces": [{ "id": "1", "backplane": "Management", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:91:bf:a2"}]}], "status": "Standby"}, {"number": "1", "name": "Node 1", "health": "Green", "fruInfo": {"mfgDate": "Tue Sep 20 17:24:00 2016", "boardMfg": "Kontron", "boardProductName": "4005", "boardProductPart": "T4005CXXX_2-CXX", "boardSerialNumber": "9013144735"},"hotswapStatus":{"state": "M4", "text": "Active"},"type":"node", "versions" : [{ "name" : "BMC", "major" : "2", "minor" : "20", "revision" : "09363399"},{ "name" : "FPGA", "major" : "3", "minor" : "00", "revision" : "00000000"},{ "name" : "BIOS", "major" : "2", "minor" : "20", "revision" : "0926E48B"}],"model": "MSP8022", "isUpdating" : "0", "managementIP": "10.24.35.96", "managementMAC": "00:a0:a5:8d:6b:c4", "alarm": {"alarmlevel": "None", "sensors":[]}, "LedIdentify": {"status": "off"}, "components": [{ "description": "Payload1       ", "number": "1", "hotswapStatus":{"state": "M1", "text": "Inactive"}, "health": "Green", "networkInterfaces": [{ "id": "1", "backplane": "Base2", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:8d:6b:c0"}, { "id": "2", "backplane": "Fabric1", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:8d:6b:c1"}]}, { "description": "Payload2       ", "number": "2", "hotswapStatus":{"state": "M1", "text": "Inactive"}, "health": "Green", "networkInterfaces": [{ "id": "1", "backplane": "Base1", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:8d:6b:c2"}, { "id": "2", "backplane": "Fabric2", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:8d:6b:c3"}]}] }, {"number": "2", "name": "Node 2", "health": "Green", "fruInfo": {"mfgDate": "Tue Sep 20 18:06:00 2016", "boardMfg": "Kontron", "boardProductName": "4005", "boardProductPart": "T4005CXXX_2-CXX", "boardSerialNumber": "9013144599"},"hotswapStatus":{"state": "M4", "text": "Active"},"type":"node", "versions" : [{ "name" : "BMC", "major" : "2", "minor" : "20", "revision" : "09363399"},{ "name" : "FPGA", "major" : "3", "minor" : "00", "revision" : "00000000"},{ "name" : "BIOS", "major" : "2", "minor" : "20", "revision" : "0926E48B"}],"model": "MSP8022", "isUpdating" : "0", "managementIP": "10.24.35.97", "managementMAC": "00:a0:a5:8d:65:1a", "alarm": {"alarmlevel": "None", "sensors":[]}, "LedIdentify": {"status": "off"}, "components": [{ "description": "Payload1       ", "number": "1", "hotswapStatus":{"state": "M1", "text": "Inactive"}, "health": "Green", "networkInterfaces": [{ "id": "1", "backplane": "Base2", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:8d:65:16"}, { "id": "2", "backplane": "Fabric1", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:8d:65:17"}]}, { "description": "Payload2       ", "number": "2", "hotswapStatus":{"state": "M1", "text": "Inactive"}, "health": "Green", "networkInterfaces": [{ "id": "1", "backplane": "Base1", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:8d:65:18"}, { "id": "2", "backplane": "Fabric2", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:8d:65:19"}]}] }, {"number": "3", "name": "Node 3", "health": "Green", "fruInfo": {"mfgDate": "Tue Sep 20 17:58:00 2016", "boardMfg": "Kontron", "boardProductName": "4005", "boardProductPart": "T4005CXXX_2-CXX", "boardSerialNumber": "9013144326"},"hotswapStatus":{"state": "M4", "text": "Active"},"type":"node", "versions" : [{ "name" : "BMC", "major" : "2", "minor" : "20", "revision" : "09363399"},{ "name" : "FPGA", "major" : "3", "minor" : "00", "revision" : "00000000"},{ "name" : "BIOS", "major" : "2", "minor" : "20", "revision" : "0926E48B"}],"model": "MSP8022", "isUpdating" : "0", "managementIP": "10.24.35.98", "managementMAC": "00:a0:a5:91:aa:7a", "alarm": {"alarmlevel": "None", "sensors":[]}, "LedIdentify": {"status": "off"}, "components": [{ "description": "Payload1       ", "number": "1", "hotswapStatus":{"state": "M1", "text": "Inactive"}, "health": "Green", "networkInterfaces": [{ "id": "1", "backplane": "Base2", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:91:aa:76"}, { "id": "2", "backplane": "Fabric1", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:91:aa:77"}]}, { "description": "Payload2       ", "number": "2", "hotswapStatus":{"state": "M1", "text": "Inactive"}, "health": "Green", "networkInterfaces": [{ "id": "1", "backplane": "Base1", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:91:aa:78"}, { "id": "2", "backplane": "Fabric2", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:91:aa:79"}]}] }, {"number": "4", "name": "Node 4", "health": "Green", "fruInfo": {"mfgDate": "Tue Sep 20 18:07:00 2016", "boardMfg": "Kontron", "boardProductName": "4005", "boardProductPart": "T4005CXXX_2-CXX", "boardSerialNumber": "9013144812"},"hotswapStatus":{"state": "M4", "text": "Active"},"type":"node", "versions" : [{ "name" : "BMC", "major" : "2", "minor" : "20", "revision" : "09363399"},{ "name" : "FPGA", "major" : "3", "minor" : "00", "revision" : "00000000"},{ "name" : "BIOS", "major" : "2", "minor" : "20", "revision" : "0926E48B"}],"model": "MSP8022", "isUpdating" : "0", "managementIP": "10.24.35.99", "managementMAC": "00:a0:a5:8d:67:be", "alarm": {"alarmlevel": "None", "sensors":[]}, "LedIdentify": {"status": "off"}, "components": [{ "description": "Payload1       ", "number": "1", "hotswapStatus":{"state": "M1", "text": "Inactive"}, "health": "Green", "networkInterfaces": [{ "id": "1", "backplane": "Base2", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:8d:67:ba"}, { "id": "2", "backplane": "Fabric1", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:8d:67:bb"}]}, { "description": "Payload2       ", "number": "2", "hotswapStatus":{"state": "M1", "text": "Inactive"}, "health": "Green", "networkInterfaces": [{ "id": "1", "backplane": "Base1", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:8d:67:bc"}, { "id": "2", "backplane": "Fabric2", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:8d:67:bd"}]}] }, {"number": "5", "name": "Node 5", "health": "Green", "fruInfo": {"mfgDate": "Tue Sep 20 17:58:00 2016", "boardMfg": "Kontron", "boardProductName": "4005", "boardProductPart": "T4005CXXX_2-CXX", "boardSerialNumber": "9013144351"},"hotswapStatus":{"state": "M4", "text": "Active"},"type":"node", "versions" : [{ "name" : "BMC", "major" : "2", "minor" : "20", "revision" : "09363399"},{ "name" : "FPGA", "major" : "3", "minor" : "00", "revision" : "00000000"},{ "name" : "BIOS", "major" : "2", "minor" : "20", "revision" : "0926E48B"}],"model": "MSP8022", "isUpdating" : "0", "managementIP": "10.24.35.100", "managementMAC": "00:a0:a5:91:aa:c8", "alarm": {"alarmlevel": "None", "sensors":[]}, "LedIdentify": {"status": "off"}, "components": [{ "description": "Payload1       ", "number": "1", "hotswapStatus":{"state": "M1", "text": "Inactive"}, "health": "Green", "networkInterfaces": [{ "id": "1", "backplane": "Base2", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:91:aa:c4"}, { "id": "2", "backplane": "Fabric1", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:91:aa:c5"}]}, { "description": "Payload2       ", "number": "2", "hotswapStatus":{"state": "M1", "text": "Inactive"}, "health": "Green", "networkInterfaces": [{ "id": "1", "backplane": "Base1", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:91:aa:c6"}, { "id": "2", "backplane": "Fabric2", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:91:aa:c7"}]}] }, {"number": "6", "name": "Node 6", "health": "Green", "fruInfo": {"mfgDate": "Thu Apr 23 17:32:00 2020", "boardMfg": "Kontron", "boardProductName": "4005", "boardProductPart": "T4005CXXX_2-CXX", "boardSerialNumber": "9017048946"},"hotswapStatus":{"state": "M4", "text": "Active"},"type":"node", "versions" : [{ "name" : "BMC", "major" : "2", "minor" : "18", "revision" : "08FA45E0"},{ "name" : "FPGA", "major" : "2", "minor" : "12", "revision" : "00000000"},{ "name" : "BIOS", "major" : "2", "minor" : "14", "revision" : "00000000"}],"model": "MSP8022", "isUpdating" : "0", "managementIP": "10.24.35.171", "managementMAC": "00:a0:a5:dc:37:9c", "alarm": {"alarmlevel": "None", "sensors":[]}, "LedIdentify": {"status": "off"}, "components": [{ "description": "Payload1       ", "number": "1", "hotswapStatus":{"state": "M1", "text": "Inactive"}, "health": "Red", "networkInterfaces": [{ "id": "1", "backplane": "Base2", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:dc:37:98"}, { "id": "2", "backplane": "Fabric1", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:dc:37:99"}]}, { "description": "Payload2       ", "number": "2", "hotswapStatus":{"state": "M1", "text": "Inactive"}, "health": "Red", "networkInterfaces": [{ "id": "1", "backplane": "Base1", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:dc:37:9a"}, { "id": "2", "backplane": "Fabric2", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:dc:37:9b"}]}] }, {"number": "7", "name": "Node 7", "health": "Green", "fruInfo": {"mfgDate": "Tue Sep 20 18:07:00 2016", "boardMfg": "Kontron", "boardProductName": "4005", "boardProductPart": "T4005CXXX_2-CXX", "boardSerialNumber": "9013144644"},"hotswapStatus":{"state": "M4", "text": "Active"},"type":"node", "versions" : [{ "name" : "BMC", "major" : "2", "minor" : "20", "revision" : "09363399"},{ "name" : "FPGA", "major" : "3", "minor" : "00", "revision" : "00000000"},{ "name" : "BIOS", "major" : "2", "minor" : "20", "revision" : "0926E48B"}],"model": "MSP8022", "isUpdating" : "0", "managementIP": "10.24.35.102", "managementMAC": "00:a0:a5:8d:66:e6", "alarm": {"alarmlevel": "None", "sensors":[]}, "LedIdentify": {"status": "off"}, "components": [{ "description": "Payload1       ", "number": "1", "hotswapStatus":{"state": "M1", "text": "Inactive"}, "health": "Green", "networkInterfaces": [{ "id": "1", "backplane": "Base2", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:8d:66:e2"}, { "id": "2", "backplane": "Fabric1", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:8d:66:e3"}]}, { "description": "Payload2       ", "number": "2", "hotswapStatus":{"state": "M1", "text": "Inactive"}, "health": "Green", "networkInterfaces": [{ "id": "1", "backplane": "Base1", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:8d:66:e4"}, { "id": "2", "backplane": "Fabric2", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:8d:66:e5"}]}] }, {"number": "8", "name": "Node 8", "health": "Green", "fruInfo": {"mfgDate": "Tue Sep 20 18:11:00 2016", "boardMfg": "Kontron", "boardProductName": "4005", "boardProductPart": "T4005CXXX_2-CXX", "boardSerialNumber": "9013144711"},"hotswapStatus":{"state": "M4", "text": "Active"},"type":"node", "versions" : [{ "name" : "BMC", "major" : "2", "minor" : "20", "revision" : "09363399"},{ "name" : "FPGA", "major" : "3", "minor" : "00", "revision" : "00000000"},{ "name" : "BIOS", "major" : "2", "minor" : "20", "revision" : "0926E48B"}],"model": "MSP8022", "isUpdating" : "0", "managementIP": "10.24.35.103", "managementMAC": "00:a0:a5:91:b2:0e", "alarm": {"alarmlevel": "None", "sensors":[]}, "LedIdentify": {"status": "off"}, "components": [{ "description": "Payload1       ", "number": "1", "hotswapStatus":{"state": "M1", "text": "Inactive"}, "health": "Green", "networkInterfaces": [{ "id": "1", "backplane": "Base2", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:91:b2:0a"}, { "id": "2", "backplane": "Fabric1", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:91:b2:0b"}]}, { "description": "Payload2       ", "number": "2", "hotswapStatus":{"state": "M1", "text": "Inactive"}, "health": "Green", "networkInterfaces": [{ "id": "1", "backplane": "Base1", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:91:b2:0c"}, { "id": "2", "backplane": "Fabric2", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:91:b2:0d"}]}] }, {"number": "9", "name": "Node 9", "health": "Green", "fruInfo": {"mfgDate": "Tue Sep 20 17:58:00 2016", "boardMfg": "Kontron", "boardProductName": "4005", "boardProductPart": "T4005CXXX_2-CXX", "boardSerialNumber": "9013144455"},"hotswapStatus":{"state": "M4", "text": "Active"},"type":"node", "versions" : [{ "name" : "BMC", "major" : "2", "minor" : "20", "revision" : "09363399"},{ "name" : "FPGA", "major" : "3", "minor" : "00", "revision" : "00000000"},{ "name" : "BIOS", "major" : "2", "minor" : "20", "revision" : "0926E48B"}],"model": "MSP8022", "isUpdating" : "0", "managementIP": "10.24.35.104", "managementMAC": "00:a0:a5:91:aa:bc", "alarm": {"alarmlevel": "None", "sensors":[]}, "LedIdentify": {"status": "off"}, "components": [{ "description": "Payload1       ", "number": "1", "hotswapStatus":{"state": "M1", "text": "Inactive"}, "health": "Green", "networkInterfaces": [{ "id": "1", "backplane": "Base2", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:91:aa:b8"}, { "id": "2", "backplane": "Fabric1", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:91:aa:b9"}]}, { "description": "Payload2       ", "number": "2", "hotswapStatus":{"state": "M1", "text": "Inactive"}, "health": "Green", "networkInterfaces": [{ "id": "1", "backplane": "Base1", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:91:aa:ba"}, { "id": "2", "backplane": "Fabric2", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:91:aa:bb"}]}] }, { "name": "PSU", "components": [{"id": "PSU1", "number": "1", "name": "Power Supply 1", "health": "Green", "type": "psu", "hotswapStatus":{"state": "M4", "text": "Active"},"alarm": {"alarmlevel": "None"}, "tempInlet": "26.00", "tempOutlet": "33.00", "vIn": "206.00", "powerOut": "48", "powerScale": "1400","peakConsumption": "168", "averageConsumption": "92"},{"id": "PSU2", "number": "2", "name": "Power Supply 2", "health": "Green", "type": "psu", "hotswapStatus":{"state": "M4", "text": "Active"},"alarm": {"alarmlevel": "None"}, "tempInlet": "26.00", "tempOutlet": "33.00", "vIn": "206.00", "powerOut": "32", "powerScale": "1400","peakConsumption": "160", "averageConsumption": "84"}]}], "switchOID": {"oid": "1.3.6.1.4.1.6603"}, "alarm": {"alarmlevel": "None",  "components" : [ {"nodes" : [] } , {"psu" : [] }, {"fans" : [] }], "text": ""}, "LedIdentify": {"status": "off"}}