System informations
*******************************
Name: SYMKLOUD
chassis: ms2900
Health: Healthy
*******************************
Fans: 
*******************************
Fan 1: 
	Present :true
	Status :Healthy
	3003 RPM
Fan 2: 
	Present :true
	Status :Healthy
	3157 RPM
Fan 3: 
	Present :true
	Status :Healthy
	3080 RPM
Fan 4: 
	Present :true
	Status :Healthy
	3157 RPM
Fan 5: 
	Present :true
	Status :Healthy
	3157 RPM


*******************************
PSU: 
*******************************
Name: PSU 1
Health: Healthy
Health Details: No details available
Hotswap Status: Active
FRU: Informations are invalid

Name: PSU 2
Health: Healthy
Health Details: No details available
Hotswap Status: Active
FRU: Informations are invalid



*******************************
HubNodes
*******************************

================================
Name: HubNode 1
Health: Healthy
Health Details: 
        Node BMC sensors aggregated for Health Status:
        | Sensor ID | Sensor Name      | Value     | Health                |
         ------------------------------------------------------------------ 
        | 0x0b      | Temp On-Board    | 38.00     | Healthy               |
        | 0x0c      | Temp Eth Switch  | 37.00     | Healthy               |
        | 0x0d      | Temp Quad Phy    | 44.00     | Healthy               |
        | 0x0e      | Temp Inlet       | 28.00     | Healthy               |
        | 0x0f      | Temp Phy 10G     | 60.00     | Healthy               |
        | 0x10      | Vcc +12V In      | 12.06     | Healthy               |
        | 0x11      | Vcc +5V SUS      | 5.12      | Healthy               |
        | 0x12      | Vcc +3.3V SUS    | 3.32      | Healthy               |
        | 0x13      | Vcc +1.8V SUS    | 1.79      | Healthy               |
        | 0x14      | Vcc +1.5V SUS    | 1.50      | Healthy               |
        | 0x15      | Vcc +1.25V SUS   | 1.25      | Healthy               |
        | 0x16      | Vcc +1.2V SUS    | 1.19      | Healthy               |
        | 0x17      | Vcc +0.75V SUS   | 0.75      | Healthy               |
        | 0x18      | Vcc +3.3V        | 3.32      | Healthy               |
        | 0x19      | Vcc +2.5V        | 2.47      | Healthy               |
        | 0x1a      | Vcc +1.8V        | 1.79      | Healthy               |
        | 0x1b      | Vcc +1.2V        | 1.22      | Healthy               |
        | 0x1c      | Vcc +1.0V        | 1.01      | Healthy               |
        | 0x1d      | Vbat +3V         | 3.15      | Healthy               |
        | 0x3f      | Power Good Latch | 0x01 0x80 | Healthy               |
        | 0x40      | FPGA RW Status   | 0x02 0x80 | Healthy               |
        | 0x41      | FPGA Heartbeat   | 0x02 0x80 | Healthy               |
        | 0x48      | ShMC Redun State | 0x02 0x80 | Healthy               |
Hotswap Status: Active
Product name: MSH8900
Part number: T4301X_2-X
Serial number: 9013133661
Manufacturing date: Wed Sep 28 18:11:00 2016
Type: HubNode
Status: Active
Model: MSH8900
HPM versions:
	BMC: 3.20.093AA546
	FPGA: 2.6.00000000
Management Network:
        Management MAC: 00:a0:a5:8a:77:a9
        IP Source: dhcp
        IP: 10.24.38.145
        Subnet: 255.255.255.0
        Gateway: 10.24.38.3
        VLAN: 4093
Payload IPs :
	Network Interfaces:
		Id: 1, 
		Backplane: Management, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:8a:77:8a
		IP Source: static

================================

================================
Name: HubNode 2
Health: Healthy
Health Details: 
        Node BMC sensors aggregated for Health Status:
        | Sensor ID | Sensor Name      | Value     | Health                |
         ------------------------------------------------------------------ 
        | 0x0b      | Temp On-Board    | 37.00     | Healthy               |
        | 0x0c      | Temp Eth Switch  | 36.00     | Healthy               |
        | 0x0d      | Temp Quad Phy    | 43.00     | Healthy               |
        | 0x0e      | Temp Inlet       | 27.00     | Healthy               |
        | 0x0f      | Temp Phy 10G     | 57.00     | Healthy               |
        | 0x10      | Vcc +12V In      | 12.06     | Healthy               |
        | 0x11      | Vcc +5V SUS      | 5.08      | Healthy               |
        | 0x12      | Vcc +3.3V SUS    | 3.31      | Healthy               |
        | 0x13      | Vcc +1.8V SUS    | 1.79      | Healthy               |
        | 0x14      | Vcc +1.5V SUS    | 1.51      | Healthy               |
        | 0x15      | Vcc +1.25V SUS   | 1.24      | Healthy               |
        | 0x16      | Vcc +1.2V SUS    | 1.19      | Healthy               |
        | 0x17      | Vcc +0.75V SUS   | 0.75      | Healthy               |
        | 0x18      | Vcc +3.3V        | 3.31      | Healthy               |
        | 0x19      | Vcc +2.5V        | 2.48      | Healthy               |
        | 0x1a      | Vcc +1.8V        | 1.79      | Healthy               |
        | 0x1b      | Vcc +1.2V        | 1.21      | Healthy               |
        | 0x1c      | Vcc +1.0V        | 1.01      | Healthy               |
        | 0x1d      | Vbat +3V         | 3.12      | Healthy               |
        | 0x3f      | Power Good Latch | 0x01 0x80 | Healthy               |
        | 0x40      | FPGA RW Status   | 0x02 0x80 | Healthy               |
        | 0x41      | FPGA Heartbeat   | 0x02 0x80 | Healthy               |
        | 0x48      | ShMC Redun State | 0x08 0x80 | Healthy               |
Hotswap Status: Active
Product name: MSH8900
Part number: T4301X_2-X
Serial number: 9013133548
Manufacturing date: Wed Sep 28 17:58:00 2016
Type: HubNode
Status: Standby
Model: MSH8900
HPM versions:
	BMC: 3.20.093AA546
	FPGA: 2.6.00000000
Management Network:
        Management MAC: 00:a0:a5:8a:a2:e1
        IP Source: dhcp
        IP: 10.24.38.112
        Subnet: 255.255.255.0
        Gateway: 10.24.38.3
        VLAN: 4093
Payload IPs :
	Network Interfaces:
		Id: 1, 
		Backplane: Management, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:8a:a2:c2
		IP Source: static

================================

*******************************
Nodes
*******************************

================================
SLOT #1
================================
Name: Node 1
Health: Healthy
Health Details: 
        Node BMC sensors aggregated for Health Status:
        | Sensor ID | Sensor Name      | Value     | Health                |
         ------------------------------------------------------------------ 
        | 0x0e      | Vcc +12.0V SUS   | 12.01     | Healthy               |
        | 0x0f      | Vcc +3.3V SUS    | 3.35      | Healthy               |
        | 0x10      | Vcc +1.5V SUS    | 1.50      | Healthy               |
        | 0x11      | Vcc +1.2V SUS    | 1.19      | Healthy               |
        | 0x04      | Temp Brd Inlet   | 32.00     | Healthy               |
        | 0x05      | Temp Brd Outlet  | 41.00     | Healthy               |
        | 0x07      | Temp BMC         | 43.00     | Healthy               |
        | 0x08      | Temp CPU 1       | 44.00     | Healthy               |
        | 0x09      | Temp CPU 2       | 37.00     | Healthy               |
        Payload Specific Health Status (for Nodes with more than 1 payload/mmc):
            Payload 1: Healthy
            Payload 2: Healthy

Hotswap Status: Active
Product name: 4005
Part number: T4005CXXX_2-CXX
Serial number: 9013144801
Manufacturing date: Tue Sep 20 18:52:00 2016
Type: Node
Model: MSP8022
HPM versions:
	BMC: 2.21.0940E3AB
	FPGA: 3.0.00000000
	BIOS: 2.21.093A2A53
Management Network:
        Management MAC: 00:a0:a5:91:ab:04
        IP Source: dhcp
        IP: 10.24.38.179
        Subnet: 255.255.255.0
        Gateway: 10.24.38.3
        VLAN: 4093
Payload IPs :
	Network Interfaces:
		Id: 1, 
		Backplane: Base2, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:91:ab:00
		IP Source: static


		Id: 2, 
		Backplane: Fabric1, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:91:ab:01
		IP Source: static


	Network Interfaces:
		Id: 1, 
		Backplane: Base1, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:91:ab:02
		IP Source: static


		Id: 2, 
		Backplane: Fabric2, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:91:ab:03
		IP Source: static

================================

================================
SLOT #2
================================
Name: Node 2
Health: Healthy
Health Details: 
        Node BMC sensors aggregated for Health Status:
        | Sensor ID | Sensor Name      | Value     | Health                |
         ------------------------------------------------------------------ 
        | 0x0e      | Vcc +12.0V SUS   | 12.06     | Healthy               |
        | 0x0f      | Vcc +3.3V SUS    | 3.35      | Healthy               |
        | 0x10      | Vcc +1.5V SUS    | 1.50      | Healthy               |
        | 0x11      | Vcc +1.2V SUS    | 1.21      | Healthy               |
        | 0x04      | Temp Brd Inlet   | 32.00     | Healthy               |
        | 0x05      | Temp Brd Outlet  | 41.00     | Healthy               |
        | 0x07      | Temp BMC         | 42.00     | Healthy               |
        | 0x08      | Temp CPU 1       | 43.00     | Healthy               |
        | 0x09      | Temp CPU 2       | 37.00     | Healthy               |
        Payload Specific Health Status (for Nodes with more than 1 payload/mmc):
            Payload 1: Healthy
            Payload 2: Healthy

Hotswap Status: Active
Product name: 4005
Part number: T4005CXXX_2-CXX
Serial number: 9013144398
Manufacturing date: Tue Sep 20 18:10:00 2016
Type: Node
Model: MSP8022
HPM versions:
	BMC: 2.21.0940E3AB
	FPGA: 3.0.00000000
	BIOS: 2.21.093A2A53
Management Network:
        Management MAC: 00:a0:a5:8d:66:48
        IP Source: dhcp
        IP: 10.24.38.125
        Subnet: 255.255.255.0
        Gateway: 10.24.38.3
        VLAN: 4093
Payload IPs :
	Network Interfaces:
		Id: 1, 
		Backplane: Base2, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:8d:66:44
		IP Source: static


		Id: 2, 
		Backplane: Fabric1, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:8d:66:45
		IP Source: static


	Network Interfaces:
		Id: 1, 
		Backplane: Base1, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:8d:66:46
		IP Source: static


		Id: 2, 
		Backplane: Fabric2, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:8d:66:47
		IP Source: static

================================

================================
SLOT #3
================================
Name: Node 3
Health: Healthy
Health Details: 
        Node BMC sensors aggregated for Health Status:
        | Sensor ID | Sensor Name      | Value     | Health                |
         ------------------------------------------------------------------ 
        | 0x0e      | Vcc +12.0V SUS   | 12.12     | Healthy               |
        | 0x0f      | Vcc +3.3V SUS    | 3.34      | Healthy               |
        | 0x10      | Vcc +1.5V SUS    | 1.49      | Healthy               |
        | 0x11      | Vcc +1.2V SUS    | 1.21      | Healthy               |
        | 0x04      | Temp Brd Inlet   | 31.00     | Healthy               |
        | 0x05      | Temp Brd Outlet  | 46.00     | Healthy               |
        | 0x07      | Temp BMC         | 47.00     | Healthy               |
        | 0x08      | Temp CPU 1       | 54.00     | Healthy               |
        | 0x09      | Temp CPU 2       | 43.00     | Healthy               |
        Payload Specific Health Status (for Nodes with more than 1 payload/mmc):
            Payload 1: Healthy
            Payload 2: Healthy

Hotswap Status: Active
Product name: 4005
Part number: T4005CXXX_2-CXX
Serial number: 9017048939
Manufacturing date: Thu Apr 23 18:21:00 2020
Type: Node
Model: MSP8022
HPM versions:
	BMC: 2.21.0940E3AB
	FPGA: 3.0.00000000
	BIOS: 2.21.093A2A53
Management Network:
        Management MAC: 00:a0:a5:dc:2f:ae
        IP Source: dhcp
        IP: 10.24.38.180
        Subnet: 255.255.255.0
        Gateway: 10.24.38.3
        VLAN: 4093
Payload IPs :
	Network Interfaces:
		Id: 1, 
		Backplane: Base2, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:dc:2f:aa
		IP Source: static


		Id: 2, 
		Backplane: Fabric1, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:dc:2f:ab
		IP Source: static


	Network Interfaces:
		Id: 1, 
		Backplane: Base1, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:dc:2f:ac
		IP Source: static


		Id: 2, 
		Backplane: Fabric2, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:dc:2f:ad
		IP Source: static

================================

================================
SLOT #4
================================
Name: Node 4
Health: Healthy
Health Details: 
        Node BMC sensors aggregated for Health Status:
        | Sensor ID | Sensor Name      | Value     | Health                |
         ------------------------------------------------------------------ 
        | 0x0e      | Vcc +12.0V SUS   | 12.06     | Healthy               |
        | 0x0f      | Vcc +3.3V SUS    | 3.35      | Healthy               |
        | 0x10      | Vcc +1.5V SUS    | 1.50      | Healthy               |
        | 0x11      | Vcc +1.2V SUS    | 1.21      | Healthy               |
        | 0x04      | Temp Brd Inlet   | 29.00     | Healthy               |
        | 0x05      | Temp Brd Outlet  | 41.00     | Healthy               |
        | 0x07      | Temp BMC         | 41.00     | Healthy               |
        | 0x08      | Temp CPU 1       | 42.00     | Healthy               |
        | 0x09      | Temp CPU 2       | 36.00     | Healthy               |
        Payload Specific Health Status (for Nodes with more than 1 payload/mmc):
            Payload 1: Healthy
            Payload 2: Healthy

Hotswap Status: Active
Product name: 4005
Part number: T4005CXXX_2-CXX
Serial number: 9013144491
Manufacturing date: Tue Sep 20 18:11:00 2016
Type: Node
Model: MSP8022
HPM versions:
	BMC: 2.21.0940E3AB
	FPGA: 3.0.00000000
	BIOS: 2.21.093A2A53
Management Network:
        Management MAC: 00:a0:a5:91:aa:c2
        IP Source: dhcp
        IP: 10.24.38.185
        Subnet: 255.255.255.0
        Gateway: 10.24.38.3
        VLAN: 4093
Payload IPs :
	Network Interfaces:
		Id: 1, 
		Backplane: Base2, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:91:aa:be
		IP Source: static


		Id: 2, 
		Backplane: Fabric1, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:91:aa:bf
		IP Source: static


	Network Interfaces:
		Id: 1, 
		Backplane: Base1, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:91:aa:c0
		IP Source: static


		Id: 2, 
		Backplane: Fabric2, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:91:aa:c1
		IP Source: static

================================

================================
SLOT #5
================================
Name: Node 5
Health: Healthy
Health Details: 
        Node BMC sensors aggregated for Health Status:
        | Sensor ID | Sensor Name      | Value     | Health                |
         ------------------------------------------------------------------ 
        | 0x0e      | Vcc +12.0V SUS   | 11.95     | Healthy               |
        | 0x0f      | Vcc +3.3V SUS    | 3.37      | Healthy               |
        | 0x10      | Vcc +1.5V SUS    | 1.50      | Healthy               |
        | 0x11      | Vcc +1.2V SUS    | 1.19      | Healthy               |
        | 0x04      | Temp Brd Inlet   | 29.00     | Healthy               |
        | 0x05      | Temp Brd Outlet  | 42.00     | Healthy               |
        | 0x07      | Temp BMC         | 42.00     | Healthy               |
        | 0x08      | Temp CPU 1       | 47.00     | Healthy               |
        | 0x09      | Temp CPU 2       | 37.00     | Healthy               |
        Payload Specific Health Status (for Nodes with more than 1 payload/mmc):
            Payload 1: Healthy
            Payload 2: Healthy

Hotswap Status: Active
Product name: 4005
Part number: T4005CXXX_2-CXX
Serial number: 9013144765
Manufacturing date: Tue Sep 20 17:21:00 2016
Type: Node
Model: MSP8022
HPM versions:
	BMC: 2.21.0940E3AB
	FPGA: 3.0.00000000
	BIOS: 2.21.093A2A53
Management Network:
        Management MAC: 00:a0:a5:91:b1:b0
        IP Source: dhcp
        IP: 10.24.38.175
        Subnet: 255.255.255.0
        Gateway: 10.24.38.3
        VLAN: 4093
Payload IPs :
	Network Interfaces:
		Id: 1, 
		Backplane: Base2, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:91:b1:ac
		IP Source: static


		Id: 2, 
		Backplane: Fabric1, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:91:b1:ad
		IP Source: static


	Network Interfaces:
		Id: 1, 
		Backplane: Base1, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:91:b1:ae
		IP Source: static


		Id: 2, 
		Backplane: Fabric2, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:91:b1:af
		IP Source: static

================================

================================
SLOT #6
================================
Name: Node 6
Health: Healthy
Health Details: 
        Node BMC sensors aggregated for Health Status:
        | Sensor ID | Sensor Name      | Value     | Health                |
         ------------------------------------------------------------------ 
        | 0x0e      | Vcc +12.0V SUS   | 12.01     | Healthy               |
        | 0x0f      | Vcc +3.3V SUS    | 3.35      | Healthy               |
        | 0x10      | Vcc +1.5V SUS    | 1.49      | Healthy               |
        | 0x11      | Vcc +1.2V SUS    | 1.21      | Healthy               |
        | 0x04      | Temp Brd Inlet   | 31.00     | Healthy               |
        | 0x05      | Temp Brd Outlet  | 44.00     | Healthy               |
        | 0x07      | Temp BMC         | 44.00     | Healthy               |
        | 0x08      | Temp CPU 1       | 47.00     | Healthy               |
        | 0x09      | Temp CPU 2       | 40.00     | Healthy               |
        Payload Specific Health Status (for Nodes with more than 1 payload/mmc):
            Payload 1: Healthy
            Payload 2: Healthy

Hotswap Status: Active
Product name: 4005
Part number: T4005CXXX_2-CXX
Serial number: 9013144660
Manufacturing date: Tue Sep 20 18:52:00 2016
Type: Node
Model: MSP8022
HPM versions:
	BMC: 2.21.0940E3AB
	FPGA: 3.0.00000000
	BIOS: 2.21.093A2A53
Management Network:
        Management MAC: 00:a0:a5:91:ac:2c
        IP Source: dhcp
        IP: 10.24.38.140
        Subnet: 255.255.255.0
        Gateway: 10.24.38.3
        VLAN: 4093
Payload IPs :
	Network Interfaces:
		Id: 1, 
		Backplane: Base2, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:91:ac:28
		IP Source: static


		Id: 2, 
		Backplane: Fabric1, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:91:ac:29
		IP Source: static


	Network Interfaces:
		Id: 1, 
		Backplane: Base1, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:91:ac:2a
		IP Source: static


		Id: 2, 
		Backplane: Fabric2, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:91:ac:2b
		IP Source: static

================================

================================
SLOT #7
================================
Name: Node 7
Health: Healthy
Health Details: 
        Node BMC sensors aggregated for Health Status:
        | Sensor ID | Sensor Name      | Value     | Health                |
         ------------------------------------------------------------------ 
        | 0x0e      | Vcc +12.0V SUS   | 11.95     | Healthy               |
        | 0x0f      | Vcc +3.3V SUS    | 3.35      | Healthy               |
        | 0x10      | Vcc +1.5V SUS    | 1.49      | Healthy               |
        | 0x11      | Vcc +1.2V SUS    | 1.21      | Healthy               |
        | 0x04      | Temp Brd Inlet   | 28.00     | Healthy               |
        | 0x05      | Temp Brd Outlet  | 40.00     | Healthy               |
        | 0x07      | Temp BMC         | 42.00     | Healthy               |
        | 0x08      | Temp CPU 1       | 45.00     | Healthy               |
        | 0x09      | Temp CPU 2       | 36.00     | Healthy               |
        Payload Specific Health Status (for Nodes with more than 1 payload/mmc):
            Payload 1: Healthy
            Payload 2: Healthy

Hotswap Status: Active
Product name: 4005
Part number: T4005CXXX_2-CXX
Serial number: 9013144779
Manufacturing date: Tue Sep 20 18:11:00 2016
Type: Node
Model: MSP8022
HPM versions:
	BMC: 2.21.0940E3AB
	FPGA: 3.0.00000000
	BIOS: 2.21.093A2A53
Management Network:
        Management MAC: 00:a0:a5:8d:74:2a
        IP Source: dhcp
        IP: 10.24.38.142
        Subnet: 255.255.255.0
        Gateway: 10.24.38.3
        VLAN: 4093
Payload IPs :
	Network Interfaces:
		Id: 1, 
		Backplane: Base2, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:8d:74:26
		IP Source: static


		Id: 2, 
		Backplane: Fabric1, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:8d:74:27
		IP Source: static


	Network Interfaces:
		Id: 1, 
		Backplane: Base1, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:8d:74:28
		IP Source: static


		Id: 2, 
		Backplane: Fabric2, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:8d:74:29
		IP Source: static

================================

================================
SLOT #8
================================
Name: Node 8
Health: Healthy
Health Details: 
        Node BMC sensors aggregated for Health Status:
        | Sensor ID | Sensor Name      | Value     | Health                |
         ------------------------------------------------------------------ 
        | 0x0e      | Vcc +12.0V SUS   | 12.06     | Healthy               |
        | 0x0f      | Vcc +3.3V SUS    | 3.35      | Healthy               |
        | 0x10      | Vcc +1.5V SUS    | 1.50      | Healthy               |
        | 0x11      | Vcc +1.2V SUS    | 1.19      | Healthy               |
        | 0x04      | Temp Brd Inlet   | 29.00     | Healthy               |
        | 0x05      | Temp Brd Outlet  | 40.00     | Healthy               |
        | 0x07      | Temp BMC         | 40.00     | Healthy               |
        | 0x08      | Temp CPU 1       | 44.00     | Healthy               |
        | 0x09      | Temp CPU 2       | 34.00     | Healthy               |
        Payload Specific Health Status (for Nodes with more than 1 payload/mmc):
            Payload 1: Healthy
            Payload 2: Healthy

Hotswap Status: Active
Product name: 4005
Part number: T4005CXXX_2-CXX
Serial number: 9013144751
Manufacturing date: Tue Sep 20 17:16:00 2016
Type: Node
Model: MSP8022
HPM versions:
	BMC: 2.21.0940E3AB
	FPGA: 3.0.00000000
	BIOS: 2.21.093A2A53
Management Network:
        Management MAC: 00:a0:a5:91:b5:f6
        IP Source: dhcp
        IP: 10.24.38.171
        Subnet: 255.255.255.0
        Gateway: 10.24.38.3
        VLAN: 4093
Payload IPs :
	Network Interfaces:
		Id: 1, 
		Backplane: Base2, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:91:b5:f2
		IP Source: static


		Id: 2, 
		Backplane: Fabric1, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:91:b5:f3
		IP Source: static


	Network Interfaces:
		Id: 1, 
		Backplane: Base1, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:91:b5:f4
		IP Source: static


		Id: 2, 
		Backplane: Fabric2, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:91:b5:f5
		IP Source: static

================================

================================
SLOT #9
================================
Name: Node 9
Health: Healthy
Health Details: 
        Node BMC sensors aggregated for Health Status:
        | Sensor ID | Sensor Name      | Value     | Health                |
         ------------------------------------------------------------------ 
        | 0x0e      | Vcc +12.0V SUS   | 12.06     | Healthy               |
        | 0x0f      | Vcc +3.3V SUS    | 3.35      | Healthy               |
        | 0x10      | Vcc +1.5V SUS    | 1.50      | Healthy               |
        | 0x11      | Vcc +1.2V SUS    | 1.21      | Healthy               |
        | 0x04      | Temp Brd Inlet   | 31.00     | Healthy               |
        | 0x05      | Temp Brd Outlet  | 41.00     | Healthy               |
        | 0x07      | Temp BMC         | 42.00     | Healthy               |
        | 0x08      | Temp CPU 1       | 46.00     | Healthy               |
        | 0x09      | Temp CPU 2       | 38.00     | Healthy               |
        Payload Specific Health Status (for Nodes with more than 1 payload/mmc):
            Payload 1: Healthy
            Payload 2: Healthy

Hotswap Status: Active
Product name: 4005
Part number: T4005CXXX_2-CXX
Serial number: 9013144681
Manufacturing date: Tue Sep 20 17:16:00 2016
Type: Node
Model: MSP8022
HPM versions:
	BMC: 2.21.0940E3AB
	FPGA: 3.0.00000000
	BIOS: 2.21.093A2A53
Management Network:
        Management MAC: 00:a0:a5:8d:75:f8
        IP Source: dhcp
        IP: 10.24.38.126
        Subnet: 255.255.255.0
        Gateway: 10.24.38.3
        VLAN: 4093
Payload IPs :
	Network Interfaces:
		Id: 1, 
		Backplane: Base2, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:8d:75:f4
		IP Source: static


		Id: 2, 
		Backplane: Fabric1, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:8d:75:f5
		IP Source: static


	Network Interfaces:
		Id: 1, 
		Backplane: Base1, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:8d:75:f6
		IP Source: static


		Id: 2, 
		Backplane: Fabric2, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:8d:75:f7
		IP Source: static

================================

*******************************
Original JSON string
*******************************
{ "name": "Platform #1", "number": "1", "chassis": "ms2900", "health": "Green", "fans":[ {"number": "1", "name": "Fan 1", "type": "fan", "health": "Green", "rpm": "3003","alarm": {"alarmlevel": "None"}, "LedIdentify": {"status": "off"}, "hotswapStatus":{"state": "M4", "text": "Active"}}, {"number": "2", "name": "Fan 2", "type": "fan", "health": "Green", "rpm": "3080","alarm": {"alarmlevel": "None"}, "LedIdentify": {"status": "off"}, "hotswapStatus":{"state": "M4", "text": "Active"}}, {"number": "3", "name": "Fan 3", "type": "fan", "health": "Green", "rpm": "3080","alarm": {"alarmlevel": "None"}, "LedIdentify": {"status": "off"}, "hotswapStatus":{"state": "M4", "text": "Active"}}, {"number": "4", "name": "Fan 4", "type": "fan", "health": "Green", "rpm": "3157","alarm": {"alarmlevel": "None"}, "LedIdentify": {"status": "off"}, "hotswapStatus":{"state": "M4", "text": "Active"}}, {"number": "5", "name": "Fan 5", "type": "fan", "health": "Green", "rpm": "3157","alarm": {"alarmlevel": "None"}, "LedIdentify": {"status": "off"}, "hotswapStatus":{"state": "M4", "text": "Active"}} ], "type": "platform", "components": [{"number": "10", "name": "HubNode 1", "health": "Green", "fruInfo": {"mfgDate": "Wed Sep 28 18:11:00 2016", "boardMfg": "Kontron", "boardProductName": "MSH8900", "boardProductPart": "T4301X_2-X", "boardSerialNumber": "9013133661"},"hotswapStatus":{"state": "M4", "text": "Active"},"type":"hubnode", "HubNodeFeatures":{"SwitchSpeedSupport": "1", "PortModeSupport": "0"}, "versions" : [{ "name" : "BMC", "major" : "3", "minor" : "20", "revision" : "093AA546"},{ "name" : "FPGA", "major" : "2", "minor" : "06", "revision" : "00000000"}],"model": "MSH8900", "isUpdating" : "0", "managementIP": "10.24.38.145", "managementMAC": "00:a0:a5:8a:77:a9", "alarm": {"alarmlevel": "None", "sensors":[]}, "LedIdentify": {"status": "off"}, "components": [{ "description": "Switch 1", "number": "1", "hotswapStatus":{"state": "M4", "text": "Active"}, "health": "Green", "networkInterfaces": [{ "id": "1", "backplane": "Management", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:8a:77:8a"}]}], "status": "Active"}, {"number": "11", "name": "HubNode 2", "health": "Green", "fruInfo": {"mfgDate": "Wed Sep 28 17:58:00 2016", "boardMfg": "Kontron", "boardProductName": "MSH8900", "boardProductPart": "T4301X_2-X", "boardSerialNumber": "9013133548"},"hotswapStatus":{"state": "M4", "text": "Active"},"type":"hubnode", "HubNodeFeatures":{"SwitchSpeedSupport": "1", "PortModeSupport": "0"}, "versions" : [{ "name" : "BMC", "major" : "3", "minor" : "20", "revision" : "093AA546"},{ "name" : "FPGA", "major" : "2", "minor" : "06", "revision" : "00000000"}],"model": "MSH8900", "isUpdating" : "0", "managementIP": "10.24.38.112", "managementMAC": "00:a0:a5:8a:a2:e1", "alarm": {"alarmlevel": "None", "sensors":[]}, "LedIdentify": {"status": "off"}, "components": [{ "description": "Switch 2", "number": "1", "hotswapStatus":{"state": "M4", "text": "Active"}, "health": "Green", "networkInterfaces": [{ "id": "1", "backplane": "Management", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:8a:a2:c2"}]}], "status": "Standby"}, {"number": "1", "name": "Node 1", "health": "Green", "fruInfo": {"mfgDate": "Tue Sep 20 18:52:00 2016", "boardMfg": "Kontron", "boardProductName": "4005", "boardProductPart": "T4005CXXX_2-CXX", "boardSerialNumber": "9013144801"},"hotswapStatus":{"state": "M4", "text": "Active"},"type":"node", "versions" : [{ "name" : "BMC", "major" : "2", "minor" : "21", "revision" : "0940E3AB"},{ "name" : "FPGA", "major" : "3", "minor" : "00", "revision" : "00000000"},{ "name" : "BIOS", "major" : "2", "minor" : "21", "revision" : "093A2A53"}],"model": "MSP8022", "isUpdating" : "0", "managementIP": "10.24.38.179", "managementMAC": "00:a0:a5:91:ab:04", "alarm": {"alarmlevel": "None", "sensors":[]}, "LedIdentify": {"status": "off"}, "components": [{ "description": "Payload1       ", "number": "1", "hotswapStatus":{"state": "M4", "text": "Active"}, "health": "Green", "networkInterfaces": [{ "id": "1", "backplane": "Base2", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:91:ab:00"}, { "id": "2", "backplane": "Fabric1", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:91:ab:01"}]}, { "description": "Payload2       ", "number": "2", "hotswapStatus":{"state": "M4", "text": "Active"}, "health": "Green", "networkInterfaces": [{ "id": "1", "backplane": "Base1", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:91:ab:02"}, { "id": "2", "backplane": "Fabric2", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:91:ab:03"}]}] }, {"number": "2", "name": "Node 2", "health": "Green", "fruInfo": {"mfgDate": "Tue Sep 20 18:10:00 2016", "boardMfg": "Kontron", "boardProductName": "4005", "boardProductPart": "T4005CXXX_2-CXX", "boardSerialNumber": "9013144398"},"hotswapStatus":{"state": "M4", "text": "Active"},"type":"node", "versions" : [{ "name" : "BMC", "major" : "2", "minor" : "21", "revision" : "0940E3AB"},{ "name" : "FPGA", "major" : "3", "minor" : "00", "revision" : "00000000"},{ "name" : "BIOS", "major" : "2", "minor" : "21", "revision" : "093A2A53"}],"model": "MSP8022", "isUpdating" : "0", "managementIP": "10.24.38.125", "managementMAC": "00:a0:a5:8d:66:48", "alarm": {"alarmlevel": "None", "sensors":[]}, "LedIdentify": {"status": "off"}, "components": [{ "description": "Payload1       ", "number": "1", "hotswapStatus":{"state": "M4", "text": "Active"}, "health": "Green", "networkInterfaces": [{ "id": "1", "backplane": "Base2", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:8d:66:44"}, { "id": "2", "backplane": "Fabric1", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:8d:66:45"}]}, { "description": "Payload2       ", "number": "2", "hotswapStatus":{"state": "M4", "text": "Active"}, "health": "Green", "networkInterfaces": [{ "id": "1", "backplane": "Base1", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:8d:66:46"}, { "id": "2", "backplane": "Fabric2", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:8d:66:47"}]}] }, {"number": "3", "name": "Node 3", "health": "Green", "fruInfo": {"mfgDate": "Thu Apr 23 18:21:00 2020", "boardMfg": "Kontron", "boardProductName": "4005", "boardProductPart": "T4005CXXX_2-CXX", "boardSerialNumber": "9017048939"},"hotswapStatus":{"state": "M4", "text": "Active"},"type":"node", "versions" : [{ "name" : "BMC", "major" : "2", "minor" : "21", "revision" : "0940E3AB"},{ "name" : "FPGA", "major" : "3", "minor" : "00", "revision" : "00000000"},{ "name" : "BIOS", "major" : "2", "minor" : "21", "revision" : "093A2A53"}],"model": "MSP8022", "isUpdating" : "0", "managementIP": "10.24.38.180", "managementMAC": "00:a0:a5:dc:2f:ae", "alarm": {"alarmlevel": "None", "sensors":[]}, "LedIdentify": {"status": "off"}, "components": [{ "description": "Payload1       ", "number": "1", "hotswapStatus":{"state": "M4", "text": "Active"}, "health": "Green", "networkInterfaces": [{ "id": "1", "backplane": "Base2", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:dc:2f:aa"}, { "id": "2", "backplane": "Fabric1", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:dc:2f:ab"}]}, { "description": "Payload2       ", "number": "2", "hotswapStatus":{"state": "M4", "text": "Active"}, "health": "Green", "networkInterfaces": [{ "id": "1", "backplane": "Base1", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:dc:2f:ac"}, { "id": "2", "backplane": "Fabric2", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:dc:2f:ad"}]}] }, {"number": "4", "name": "Node 4", "health": "Green", "fruInfo": {"mfgDate": "Tue Sep 20 18:11:00 2016", "boardMfg": "Kontron", "boardProductName": "4005", "boardProductPart": "T4005CXXX_2-CXX", "boardSerialNumber": "9013144491"},"hotswapStatus":{"state": "M4", "text": "Active"},"type":"node", "versions" : [{ "name" : "BMC", "major" : "2", "minor" : "21", "revision" : "0940E3AB"},{ "name" : "FPGA", "major" : "3", "minor" : "00", "revision" : "00000000"},{ "name" : "BIOS", "major" : "2", "minor" : "21", "revision" : "093A2A53"}],"model": "MSP8022", "isUpdating" : "0", "managementIP": "10.24.38.185", "managementMAC": "00:a0:a5:91:aa:c2", "alarm": {"alarmlevel": "None", "sensors":[]}, "LedIdentify": {"status": "off"}, "components": [{ "description": "Payload1       ", "number": "1", "hotswapStatus":{"state": "M4", "text": "Active"}, "health": "Green", "networkInterfaces": [{ "id": "1", "backplane": "Base2", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:91:aa:be"}, { "id": "2", "backplane": "Fabric1", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:91:aa:bf"}]}, { "description": "Payload2       ", "number": "2", "hotswapStatus":{"state": "M4", "text": "Active"}, "health": "Green", "networkInterfaces": [{ "id": "1", "backplane": "Base1", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:91:aa:c0"}, { "id": "2", "backplane": "Fabric2", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:91:aa:c1"}]}] }, {"number": "5", "name": "Node 5", "health": "Green", "fruInfo": {"mfgDate": "Tue Sep 20 17:21:00 2016", "boardMfg": "Kontron", "boardProductName": "4005", "boardProductPart": "T4005CXXX_2-CXX", "boardSerialNumber": "9013144765"},"hotswapStatus":{"state": "M4", "text": "Active"},"type":"node", "versions" : [{ "name" : "BMC", "major" : "2", "minor" : "21", "revision" : "0940E3AB"},{ "name" : "FPGA", "major" : "3", "minor" : "00", "revision" : "00000000"},{ "name" : "BIOS", "major" : "2", "minor" : "21", "revision" : "093A2A53"}],"model": "MSP8022", "isUpdating" : "0", "managementIP": "10.24.38.175", "managementMAC": "00:a0:a5:91:b1:b0", "alarm": {"alarmlevel": "None", "sensors":[]}, "LedIdentify": {"status": "off"}, "components": [{ "description": "Payload1       ", "number": "1", "hotswapStatus":{"state": "M4", "text": "Active"}, "health": "Green", "networkInterfaces": [{ "id": "1", "backplane": "Base2", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:91:b1:ac"}, { "id": "2", "backplane": "Fabric1", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:91:b1:ad"}]}, { "description": "Payload2       ", "number": "2", "hotswapStatus":{"state": "M4", "text": "Active"}, "health": "Green", "networkInterfaces": [{ "id": "1", "backplane": "Base1", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:91:b1:ae"}, { "id": "2", "backplane": "Fabric2", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:91:b1:af"}]}] }, {"number": "6", "name": "Node 6", "health": "Green", "fruInfo": {"mfgDate": "Tue Sep 20 18:52:00 2016", "boardMfg": "Kontron", "boardProductName": "4005", "boardProductPart": "T4005CXXX_2-CXX", "boardSerialNumber": "9013144660"},"hotswapStatus":{"state": "M4", "text": "Active"},"type":"node", "versions" : [{ "name" : "BMC", "major" : "2", "minor" : "21", "revision" : "0940E3AB"},{ "name" : "FPGA", "major" : "3", "minor" : "00", "revision" : "00000000"},{ "name" : "BIOS", "major" : "2", "minor" : "21", "revision" : "093A2A53"}],"model": "MSP8022", "isUpdating" : "0", "managementIP": "10.24.38.140", "managementMAC": "00:a0:a5:91:ac:2c", "alarm": {"alarmlevel": "None", "sensors":[]}, "LedIdentify": {"status": "off"}, "components": [{ "description": "Payload1       ", "number": "1", "hotswapStatus":{"state": "M4", "text": "Active"}, "health": "Green", "networkInterfaces": [{ "id": "1", "backplane": "Base2", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:91:ac:28"}, { "id": "2", "backplane": "Fabric1", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:91:ac:29"}]}, { "description": "Payload2       ", "number": "2", "hotswapStatus":{"state": "M4", "text": "Active"}, "health": "Green", "networkInterfaces": [{ "id": "1", "backplane": "Base1", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:91:ac:2a"}, { "id": "2", "backplane": "Fabric2", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:91:ac:2b"}]}] }, {"number": "7", "name": "Node 7", "health": "Green", "fruInfo": {"mfgDate": "Tue Sep 20 18:11:00 2016", "boardMfg": "Kontron", "boardProductName": "4005", "boardProductPart": "T4005CXXX_2-CXX", "boardSerialNumber": "9013144779"},"hotswapStatus":{"state": "M4", "text": "Active"},"type":"node", "versions" : [{ "name" : "BMC", "major" : "2", "minor" : "21", "revision" : "0940E3AB"},{ "name" : "FPGA", "major" : "3", "minor" : "00", "revision" : "00000000"},{ "name" : "BIOS", "major" : "2", "minor" : "21", "revision" : "093A2A53"}],"model": "MSP8022", "isUpdating" : "0", "managementIP": "10.24.38.142", "managementMAC": "00:a0:a5:8d:74:2a", "alarm": {"alarmlevel": "None", "sensors":[]}, "LedIdentify": {"status": "off"}, "components": [{ "description": "Payload1       ", "number": "1", "hotswapStatus":{"state": "M4", "text": "Active"}, "health": "Green", "networkInterfaces": [{ "id": "1", "backplane": "Base2", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:8d:74:26"}, { "id": "2", "backplane": "Fabric1", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:8d:74:27"}]}, { "description": "Payload2       ", "number": "2", "hotswapStatus":{"state": "M4", "text": "Active"}, "health": "Green", "networkInterfaces": [{ "id": "1", "backplane": "Base1", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:8d:74:28"}, { "id": "2", "backplane": "Fabric2", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:8d:74:29"}]}] }, {"number": "8", "name": "Node 8", "health": "Green", "fruInfo": {"mfgDate": "Tue Sep 20 17:16:00 2016", "boardMfg": "Kontron", "boardProductName": "4005", "boardProductPart": "T4005CXXX_2-CXX", "boardSerialNumber": "9013144751"},"hotswapStatus":{"state": "M4", "text": "Active"},"type":"node", "versions" : [{ "name" : "BMC", "major" : "2", "minor" : "21", "revision" : "0940E3AB"},{ "name" : "FPGA", "major" : "3", "minor" : "00", "revision" : "00000000"},{ "name" : "BIOS", "major" : "2", "minor" : "21", "revision" : "093A2A53"}],"model": "MSP8022", "isUpdating" : "0", "managementIP": "10.24.38.171", "managementMAC": "00:a0:a5:91:b5:f6", "alarm": {"alarmlevel": "None", "sensors":[]}, "LedIdentify": {"status": "off"}, "components": [{ "description": "Payload1       ", "number": "1", "hotswapStatus":{"state": "M4", "text": "Active"}, "health": "Green", "networkInterfaces": [{ "id": "1", "backplane": "Base2", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:91:b5:f2"}, { "id": "2", "backplane": "Fabric1", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:91:b5:f3"}]}, { "description": "Payload2       ", "number": "2", "hotswapStatus":{"state": "M4", "text": "Active"}, "health": "Green", "networkInterfaces": [{ "id": "1", "backplane": "Base1", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:91:b5:f4"}, { "id": "2", "backplane": "Fabric2", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:91:b5:f5"}]}] }, {"number": "9", "name": "Node 9", "health": "Green", "fruInfo": {"mfgDate": "Tue Sep 20 17:16:00 2016", "boardMfg": "Kontron", "boardProductName": "4005", "boardProductPart": "T4005CXXX_2-CXX", "boardSerialNumber": "9013144681"},"hotswapStatus":{"state": "M4", "text": "Active"},"type":"node", "versions" : [{ "name" : "BMC", "major" : "2", "minor" : "21", "revision" : "0940E3AB"},{ "name" : "FPGA", "major" : "3", "minor" : "00", "revision" : "00000000"},{ "name" : "BIOS", "major" : "2", "minor" : "21", "revision" : "093A2A53"}],"model": "MSP8022", "isUpdating" : "0", "managementIP": "10.24.38.126", "managementMAC": "00:a0:a5:8d:75:f8", "alarm": {"alarmlevel": "None", "sensors":[]}, "LedIdentify": {"status": "off"}, "components": [{ "description": "Payload1       ", "number": "1", "hotswapStatus":{"state": "M4", "text": "Active"}, "health": "Green", "networkInterfaces": [{ "id": "1", "backplane": "Base2", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:8d:75:f4"}, { "id": "2", "backplane": "Fabric1", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:8d:75:f5"}]}, { "description": "Payload2       ", "number": "2", "hotswapStatus":{"state": "M4", "text": "Active"}, "health": "Green", "networkInterfaces": [{ "id": "1", "backplane": "Base1", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:8d:75:f6"}, { "id": "2", "backplane": "Fabric2", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:8d:75:f7"}]}] }, { "name": "PSU", "components": [{"id": "PSU1", "number": "1", "name": "Power Supply 1", "health": "Green", "type": "psu", "hotswapStatus":{"state": "M4", "text": "Active"},"alarm": {"alarmlevel": "None"}, "tempInlet": "28.00", "tempOutlet": "36.00", "vIn": "205.00", "powerOut": "112", "powerScale": "1400","peakConsumption": "200", "averageConsumption": "118"},{"id": "PSU2", "number": "2", "name": "Power Supply 2", "health": "Green", "type": "psu", "hotswapStatus":{"state": "M4", "text": "Active"},"alarm": {"alarmlevel": "None"}, "tempInlet": "28.00", "tempOutlet": "37.00", "vIn": "202.00", "powerOut": "112", "powerScale": "1400","peakConsumption": "208", "averageConsumption": "121"}]}], "switchOID": {"oid": "1.3.6.1.4.1.6603"}, "alarm": {"alarmlevel": "None",  "components" : [ {"nodes" : [] } , {"psu" : [] }, {"fans" : [] }], "text": ""}, "LedIdentify": {"status": "off"}}