System informations
*******************************
Name: SYMKLOUD
chassis: ms2900
Health: Healthy
*******************************
Fans: 
*******************************
Fan 1: 
	Present :true
	Status :Healthy
	5698 RPM
Fan 2: 
	Present :true
	Status :Healthy
	5698 RPM
Fan 3: 
	Present :true
	Status :Healthy
	5775 RPM
Fan 4: 
	Present :true
	Status :Healthy
	5852 RPM
Fan 5: 
	Present :true
	Status :Healthy
	5852 RPM


*******************************
PSU: 
*******************************
Name: PSU 1
Health: Healthy
Health Details: No details available
Hotswap Status: Active
FRU: Informations are invalid

Name: PSU 2
Health: Healthy
Health Details: No details available
Hotswap Status: Active
FRU: Informations are invalid



*******************************
HubNodes
*******************************

================================
Name: HubNode 1
Health: Healthy
Health Details: 
        | Sensor ID | Sensor Name      | Value   | Health                |
         ---------------------------------------------------------------- 
        | 0x0b      | Temp On-Board    | 32.00   | Healthy               |
        | 0x0c      | Temp Eth Switch  | 32.00   | Healthy               |
        | 0x0d      | Temp Quad Phy    | 38.00   | Healthy               |
        | 0x0e      | Temp Inlet       | 23.00   | Healthy               |
        | 0x0f      | Temp Phy 10G     | 54.00   | Healthy               |
        | 0x10      | Vcc +12V In      | 12.06   | Healthy               |
        | 0x11      | Vcc +5V SUS      | 5.08    | Healthy               |
        | 0x12      | Vcc +3.3V SUS    | 3.31    | Healthy               |
        | 0x13      | Vcc +1.8V SUS    | 1.78    | Healthy               |
        | 0x14      | Vcc +1.5V SUS    | 1.50    | Healthy               |
        | 0x15      | Vcc +1.25V SUS   | 1.24    | Healthy               |
        | 0x16      | Vcc +1.2V SUS    | 1.19    | Healthy               |
        | 0x17      | Vcc +0.75V SUS   | 0.75    | Healthy               |
        | 0x18      | Vcc +3.3V        | 3.31    | Healthy               |
        | 0x19      | Vcc +2.5V        | 2.47    | Healthy               |
        | 0x1a      | Vcc +1.8V        | 1.78    | Healthy               |
        | 0x1b      | Vcc +1.2V        | 1.21    | Healthy               |
        | 0x1c      | Vcc +1.0V        | 1.01    | Healthy               |
        | 0x1d      | Vbat +3V         | 3.07    | Healthy               |
        | 0x3f      | Power Good Latch | 0x8001  | Healthy               |
        | 0x40      | FPGA RW Status   | 0x8002  | Healthy               |
        | 0x41      | FPGA Heartbeat   | 0x8002  | Healthy               |
        | 0x48      | ShMC Redun State | 0x8008  | Healthy               |
Hotswap Status: Active
Product name: MSH8900
Part number: T4301X_2-X
Serial number: 9013123954
Manufacturing date: Mon Jun 27 13:19:00 2016
Type: HubNode
Status: Standby
Model: MSH8900
HPM versions:
	BMC: 3.18.093413FB
	FPGA: 2.4.00000000
Management Network:
        Management MAC: 00:a0:a5:89:db:4b
        IP Source: dhcp
        IP: 10.24.46.169
        Subnet: 255.255.255.0
        Gateway: 10.24.46.3
        VLAN: FFD
Payload IPs :
	Network Interfaces:
		Id: 1, 
		Backplane: Management, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:89:db:2c
		IP Source: static

================================

================================
Name: HubNode 2
Health: Healthy
Health Details: 
        | Sensor ID | Sensor Name      | Value   | Health                |
         ---------------------------------------------------------------- 
        | 0x0b      | Temp On-Board    | 31.00   | Healthy               |
        | 0x0c      | Temp Eth Switch  | 32.00   | Healthy               |
        | 0x0d      | Temp Quad Phy    | 39.00   | Healthy               |
        | 0x0e      | Temp Inlet       | 23.00   | Healthy               |
        | 0x0f      | Temp Phy 10G     | 51.00   | Healthy               |
        | 0x10      | Vcc +12V In      | 12.01   | Healthy               |
        | 0x11      | Vcc +5V SUS      | 5.08    | Healthy               |
        | 0x12      | Vcc +3.3V SUS    | 3.31    | Healthy               |
        | 0x13      | Vcc +1.8V SUS    | 1.78    | Healthy               |
        | 0x14      | Vcc +1.5V SUS    | 1.50    | Healthy               |
        | 0x15      | Vcc +1.25V SUS   | 1.25    | Healthy               |
        | 0x16      | Vcc +1.2V SUS    | 1.18    | Healthy               |
        | 0x17      | Vcc +0.75V SUS   | 0.75    | Healthy               |
        | 0x18      | Vcc +3.3V        | 3.31    | Healthy               |
        | 0x19      | Vcc +2.5V        | 2.47    | Healthy               |
        | 0x1a      | Vcc +1.8V        | 1.78    | Healthy               |
        | 0x1b      | Vcc +1.2V        | 1.21    | Healthy               |
        | 0x1c      | Vcc +1.0V        | 1.01    | Healthy               |
        | 0x1d      | Vbat +3V         | 3.09    | Healthy               |
        | 0x3f      | Power Good Latch | 0x8001  | Healthy               |
        | 0x40      | FPGA RW Status   | 0x8002  | Healthy               |
        | 0x41      | FPGA Heartbeat   | 0x8002  | Healthy               |
        | 0x48      | ShMC Redun State | 0x8002  | Healthy               |
Hotswap Status: Active
Product name: MSH8900
Part number: T4301X_2-X
Serial number: 9013123965
Manufacturing date: Mon Jun 27 13:52:00 2016
Type: HubNode
Status: Active
Model: MSH8900
HPM versions:
	BMC: 3.18.093413FB
	FPGA: 2.4.00000000
Management Network:
        Management MAC: 00:a0:a5:90:d3:b3
        IP Source: dhcp
        IP: 10.24.46.187
        Subnet: 255.255.255.0
        Gateway: 10.24.46.3
        VLAN: FFD
Payload IPs :
	Network Interfaces:
		Id: 1, 
		Backplane: Management, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:90:d3:94
		IP Source: static

================================

*******************************
Nodes
*******************************

================================
SLOT #1
================================
Name: Node 1
Health: Healthy
Health Details: 
        | Sensor ID | Sensor Name      | Value   | Health                |
         ---------------------------------------------------------------- 
        | 0x0e      | Vcc +12.0V SUS   | 12.01   | Healthy               |
        | 0x0f      | Vcc +3.3V SUS    | 3.35    | Healthy               |
        | 0x10      | Vcc +1.5V SUS    | 1.50    | Healthy               |
        | 0x11      | Vcc +1.2V SUS    | 1.21    | Healthy               |
        | 0x04      | Temp Brd Inlet   | 29.00   | Healthy               |
        | 0x05      | Temp Brd Outlet  | 57.00   | Healthy               |
        | 0x07      | Temp BMC         | 50.00   | Healthy               |
        | 0x08      | Temp CPU 1       | 76.00   | Healthy               |
        | 0x09      | Temp CPU 2       | 55.00   | Healthy               |
Hotswap Status: Active
Product name: 4005
Part number: T4005CXXX_2-CXX
Serial number: 9013110481
Manufacturing date: Mon May 30 17:40:00 2016
Type: Node
Model: MSP8022
HPM versions:
	BMC: 2.18.08FA45E0
	FPGA: 2.C.00000000
	BIOS: 2.E.00000000
Management Network:
        Management MAC: 00:a0:a5:90:77:1e
        IP Source: dhcp
        IP: 10.24.46.144
        Subnet: 255.255.255.0
        Gateway: 10.24.46.3
        VLAN: FFD
Payload IPs :
	Network Interfaces:
		Id: 1, 
		Backplane: Base2, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:90:77:1a
		IP Source: dhcp


		Id: 2, 
		Backplane: Fabric1, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:90:77:1b
		IP Source: static


	Network Interfaces:
		Id: 1, 
		Backplane: Base1, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:90:77:1c
		IP Source: dhcp


		Id: 2, 
		Backplane: Fabric2, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:90:77:1d
		IP Source: static

================================

================================
SLOT #2
================================
Name: Node 2
Health: Healthy
Health Details: 
        | Sensor ID | Sensor Name      | Value   | Health                |
         ---------------------------------------------------------------- 
        | 0x0e      | Vcc +12.0V SUS   | 12.06   | Healthy               |
        | 0x0f      | Vcc +3.3V SUS    | 3.34    | Healthy               |
        | 0x10      | Vcc +1.5V SUS    | 1.50    | Healthy               |
        | 0x11      | Vcc +1.2V SUS    | 1.21    | Healthy               |
        | 0x04      | Temp Brd Inlet   | 28.00   | Healthy               |
        | 0x05      | Temp Brd Outlet  | 49.00   | Healthy               |
        | 0x07      | Temp BMC         | 44.00   | Healthy               |
        | 0x08      | Temp CPU 1       | 60.00   | Healthy               |
        | 0x09      | Temp CPU 2       | 45.00   | Healthy               |
Hotswap Status: Active
Product name: 4005
Part number: T4005CXXX_2-CXX
Serial number: 9013101130
Manufacturing date: Mon May 30 17:40:00 2016
Type: Node
Model: MSP8022
HPM versions:
	BMC: 2.18.08FA45E0
	FPGA: 2.C.00000000
	BIOS: 2.E.00000000
Management Network:
        Management MAC: 00:a0:a5:88:7c:74
        IP Source: dhcp
        IP: 10.24.46.152
        Subnet: 255.255.255.0
        Gateway: 10.24.46.3
        VLAN: FFD
Payload IPs :
	Network Interfaces:
		Id: 1, 
		Backplane: Base2, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:88:7c:70
		IP Source: dhcp


		Id: 2, 
		Backplane: Fabric1, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:88:7c:71
		IP Source: static


	Network Interfaces:
		Id: 1, 
		Backplane: Base1, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:88:7c:72
		IP Source: dhcp


		Id: 2, 
		Backplane: Fabric2, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:88:7c:73
		IP Source: static

================================

================================
SLOT #3
================================
Name: Node 3
Health: Healthy
Health Details: 
        | Sensor ID | Sensor Name      | Value   | Health                |
         ---------------------------------------------------------------- 
        | 0x0e      | Vcc +12.0V SUS   | 12.01   | Healthy               |
        | 0x0f      | Vcc +3.3V SUS    | 3.34    | Healthy               |
        | 0x10      | Vcc +1.5V SUS    | 1.50    | Healthy               |
        | 0x11      | Vcc +1.2V SUS    | 1.19    | Healthy               |
        | 0x04      | Temp Brd Inlet   | 25.00   | Healthy               |
        | 0x05      | Temp Brd Outlet  | 53.00   | Healthy               |
        | 0x07      | Temp BMC         | 45.00   | Healthy               |
        | 0x08      | Temp CPU 1       | 69.00   | Healthy               |
        | 0x09      | Temp CPU 2       | 46.00   | Healthy               |
Hotswap Status: Active
Product name: 4005
Part number: T4005CXXX_2-CXX
Serial number: 9013110525
Manufacturing date: Mon May 30 18:10:00 2016
Type: Node
Model: MSP8022
HPM versions:
	BMC: 2.18.08FA45E0
	FPGA: 2.C.00000000
	BIOS: 2.E.00000000
Management Network:
        Management MAC: 00:a0:a5:89:33:b6
        IP Source: dhcp
        IP: 10.24.46.151
        Subnet: 255.255.255.0
        Gateway: 10.24.46.3
        VLAN: FFD
Payload IPs :
	Network Interfaces:
		Id: 1, 
		Backplane: Base2, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:89:33:b2
		IP Source: dhcp


		Id: 2, 
		Backplane: Fabric1, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:89:33:b3
		IP Source: static


	Network Interfaces:
		Id: 1, 
		Backplane: Base1, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:89:33:b4
		IP Source: dhcp


		Id: 2, 
		Backplane: Fabric2, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:89:33:b5
		IP Source: static

================================

================================
SLOT #4
================================
Name: Node 4
Health: Healthy
Health Details: 
        | Sensor ID | Sensor Name      | Value   | Health                |
         ---------------------------------------------------------------- 
        | 0x0e      | Vcc +12.0V SUS   | 12.12   | Healthy               |
        | 0x0f      | Vcc +3.3V SUS    | 3.35    | Healthy               |
        | 0x10      | Vcc +1.5V SUS    | 1.50    | Healthy               |
        | 0x11      | Vcc +1.2V SUS    | 1.21    | Healthy               |
        | 0x04      | Temp Brd Inlet   | 25.00   | Healthy               |
        | 0x05      | Temp Brd Outlet  | 51.00   | Healthy               |
        | 0x07      | Temp BMC         | 43.00   | Healthy               |
        | 0x08      | Temp CPU 1       | 64.00   | Healthy               |
        | 0x09      | Temp CPU 2       | 44.00   | Healthy               |
Hotswap Status: Active
Product name: 4005
Part number: T4005CXXX_2-CXX
Serial number: 9013110552
Manufacturing date: Mon May 30 19:17:00 2016
Type: Node
Model: MSP8022
HPM versions:
	BMC: 2.18.08FA45E0
	FPGA: 2.C.00000000
	BIOS: 2.E.00000000
Management Network:
        Management MAC: 00:a0:a5:90:8a:ce
        IP Source: dhcp
        IP: 10.24.46.160
        Subnet: 255.255.255.0
        Gateway: 10.24.46.3
        VLAN: FFD
Payload IPs :
	Network Interfaces:
		Id: 1, 
		Backplane: Base2, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:90:8a:ca
		IP Source: dhcp


		Id: 2, 
		Backplane: Fabric1, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:90:8a:cb
		IP Source: static


	Network Interfaces:
		Id: 1, 
		Backplane: Base1, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:90:8a:cc
		IP Source: dhcp


		Id: 2, 
		Backplane: Fabric2, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:90:8a:cd
		IP Source: static

================================

================================
SLOT #5
================================
Name: Node 5
Health: Healthy
Health Details: 
        | Sensor ID | Sensor Name      | Value   | Health                |
         ---------------------------------------------------------------- 
        | 0x0e      | Vcc +12.0V SUS   | 12.06   | Healthy               |
        | 0x0f      | Vcc +3.3V SUS    | 3.35    | Healthy               |
        | 0x10      | Vcc +1.5V SUS    | 1.49    | Healthy               |
        | 0x11      | Vcc +1.2V SUS    | 1.21    | Healthy               |
        | 0x04      | Temp Brd Inlet   | 25.00   | Healthy               |
        | 0x05      | Temp Brd Outlet  | 51.00   | Healthy               |
        | 0x07      | Temp BMC         | 46.00   | Healthy               |
        | 0x08      | Temp CPU 1       | 64.00   | Healthy               |
        | 0x09      | Temp CPU 2       | 47.00   | Healthy               |
Hotswap Status: Active
Product name: 4005
Part number: T4005CXXX_2-CXX
Serial number: 9013110526
Manufacturing date: Mon May 30 19:30:00 2016
Type: Node
Model: MSP8022
HPM versions:
	BMC: 2.18.08FA45E0
	FPGA: 2.C.00000000
	BIOS: 2.E.00000000
Management Network:
        Management MAC: 00:a0:a5:90:8b:52
        IP Source: dhcp
        IP: 10.24.46.156
        Subnet: 255.255.255.0
        Gateway: 10.24.46.3
        VLAN: FFD
Payload IPs :
	Network Interfaces:
		Id: 1, 
		Backplane: Base2, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:90:8b:4e
		IP Source: dhcp


		Id: 2, 
		Backplane: Fabric1, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:90:8b:4f
		IP Source: static


	Network Interfaces:
		Id: 1, 
		Backplane: Base1, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:90:8b:50
		IP Source: dhcp


		Id: 2, 
		Backplane: Fabric2, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:90:8b:51
		IP Source: static

================================

================================
SLOT #6
================================
Name: Node 6
Health: Healthy
Health Details: 
        | Sensor ID | Sensor Name      | Value   | Health                |
         ---------------------------------------------------------------- 
        | 0x0e      | Vcc +12.0V SUS   | 12.12   | Healthy               |
        | 0x0f      | Vcc +3.3V SUS    | 3.34    | Healthy               |
        | 0x10      | Vcc +1.5V SUS    | 1.50    | Healthy               |
        | 0x11      | Vcc +1.2V SUS    | 1.19    | Healthy               |
        | 0x04      | Temp Brd Inlet   | 25.00   | Healthy               |
        | 0x05      | Temp Brd Outlet  | 51.00   | Healthy               |
        | 0x07      | Temp BMC         | 44.00   | Healthy               |
        | 0x08      | Temp CPU 1       | 65.00   | Healthy               |
        | 0x09      | Temp CPU 2       | 44.00   | Healthy               |
Hotswap Status: Active
Product name: 4005
Part number: T4005CXXX_2-CXX
Serial number: 9013110491
Manufacturing date: Mon May 30 19:26:00 2016
Type: Node
Model: MSP8022
HPM versions:
	BMC: 2.18.08FA45E0
	FPGA: 2.C.00000000
	BIOS: 2.E.00000000
Management Network:
        Management MAC: 00:a0:a5:90:77:80
        IP Source: dhcp
        IP: 10.24.46.139
        Subnet: 255.255.255.0
        Gateway: 10.24.46.3
        VLAN: FFD
Payload IPs :
	Network Interfaces:
		Id: 1, 
		Backplane: Base2, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:90:77:7c
		IP Source: dhcp


		Id: 2, 
		Backplane: Fabric1, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:90:77:7d
		IP Source: static


	Network Interfaces:
		Id: 1, 
		Backplane: Base1, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:90:77:7e
		IP Source: dhcp


		Id: 2, 
		Backplane: Fabric2, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:90:77:7f
		IP Source: static

================================

================================
SLOT #7
================================
Name: Node 7
Health: Healthy
Health Details: 
        | Sensor ID | Sensor Name      | Value   | Health                |
         ---------------------------------------------------------------- 
        | 0x0e      | Vcc +12.0V SUS   | 11.95   | Healthy               |
        | 0x0f      | Vcc +3.3V SUS    | 3.35    | Healthy               |
        | 0x10      | Vcc +1.5V SUS    | 1.50    | Healthy               |
        | 0x11      | Vcc +1.2V SUS    | 1.19    | Healthy               |
        | 0x04      | Temp Brd Inlet   | 24.00   | Healthy               |
        | 0x05      | Temp Brd Outlet  | 45.00   | Healthy               |
        | 0x07      | Temp BMC         | 38.00   | Healthy               |
        | 0x08      | Temp CPU 1       | 59.00   | Healthy               |
        | 0x09      | Temp CPU 2       | 33.00   | Healthy               |
Hotswap Status: Active
Product name: 4005
Part number: T4005CXXX_2-CXX
Serial number: 9013113468
Manufacturing date: Mon May 30 17:40:00 2016
Type: Node
Model: MSP8022
HPM versions:
	BMC: 2.18.08FA45E0
	FPGA: 2.C.00000000
	BIOS: 2.E.00000000
Management Network:
        Management MAC: 00:a0:a5:90:8a:e6
        IP Source: dhcp
        IP: 10.24.46.192
        Subnet: 255.255.255.0
        Gateway: 10.24.46.3
        VLAN: FFD
Payload IPs :
	Network Interfaces:
		Id: 1, 
		Backplane: Base2, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:90:8a:e2
		IP Source: dhcp


		Id: 2, 
		Backplane: Fabric1, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:90:8a:e3
		IP Source: static


	Network Interfaces:
		Id: 1, 
		Backplane: Base1, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:90:8a:e4
		IP Source: dhcp


		Id: 2, 
		Backplane: Fabric2, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:90:8a:e5
		IP Source: static

================================

================================
SLOT #8
================================
Name: Node 8
Health: Healthy
Health Details: 
        | Sensor ID | Sensor Name      | Value   | Health                |
         ---------------------------------------------------------------- 
        | 0x0e      | Vcc +12.0V SUS   | 12.12   | Healthy               |
        | 0x0f      | Vcc +3.3V SUS    | 3.35    | Healthy               |
        | 0x10      | Vcc +1.5V SUS    | 1.50    | Healthy               |
        | 0x11      | Vcc +1.2V SUS    | 1.21    | Healthy               |
        | 0x04      | Temp Brd Inlet   | 24.00   | Healthy               |
        | 0x05      | Temp Brd Outlet  | 52.00   | Healthy               |
        | 0x07      | Temp BMC         | 44.00   | Healthy               |
        | 0x08      | Temp CPU 1       | 76.00   | Healthy               |
        | 0x09      | Temp CPU 2       | 50.00   | Healthy               |
Hotswap Status: Active
Product name: 4005
Part number: T4005CXXX_2-CXX
Serial number: 9013110503
Manufacturing date: Mon May 30 18:08:00 2016
Type: Node
Model: MSP8022
HPM versions:
	BMC: 2.18.08FA45E0
	FPGA: 2.C.00000000
	BIOS: 2.E.00000000
Management Network:
        Management MAC: 00:a0:a5:89:0f:f6
        IP Source: dhcp
        IP: 10.24.46.125
        Subnet: 255.255.255.0
        Gateway: 10.24.46.3
        VLAN: FFD
Payload IPs :
	Network Interfaces:
		Id: 1, 
		Backplane: Base2, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:89:0f:f2
		IP Source: dhcp


		Id: 2, 
		Backplane: Fabric1, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:89:0f:f3
		IP Source: static


	Network Interfaces:
		Id: 1, 
		Backplane: Base1, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:89:0f:f4
		IP Source: dhcp


		Id: 2, 
		Backplane: Fabric2, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:89:0f:f5
		IP Source: static

================================

================================
SLOT #9
================================
Name: Node 9
Health: Healthy
Health Details: 
        | Sensor ID | Sensor Name      | Value   | Health                |
         ---------------------------------------------------------------- 
        | 0x0e      | Vcc +12.0V SUS   | 12.06   | Healthy               |
        | 0x0f      | Vcc +3.3V SUS    | 3.35    | Healthy               |
        | 0x10      | Vcc +1.5V SUS    | 1.50    | Healthy               |
        | 0x11      | Vcc +1.2V SUS    | 1.21    | Healthy               |
        | 0x04      | Temp Brd Inlet   | 26.00   | Healthy               |
        | 0x05      | Temp Brd Outlet  | 49.00   | Healthy               |
        | 0x07      | Temp BMC         | 44.00   | Healthy               |
        | 0x08      | Temp CPU 1       | 67.00   | Healthy               |
        | 0x09      | Temp CPU 2       | 53.00   | Healthy               |
Hotswap Status: Active
Product name: 4005
Part number: T4005CXXX_2-CXX
Serial number: 9013110440
Manufacturing date: Mon May 30 18:07:00 2016
Type: Node
Model: MSP8022
HPM versions:
	BMC: 2.18.08FA45E0
	FPGA: 2.C.00000000
	BIOS: 2.E.00000000
Management Network:
        Management MAC: 00:a0:a5:90:77:68
        IP Source: dhcp
        IP: 10.24.46.133
        Subnet: 255.255.255.0
        Gateway: 10.24.46.3
        VLAN: FFD
Payload IPs :
	Network Interfaces:
		Id: 1, 
		Backplane: Base2, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:90:77:64
		IP Source: dhcp


		Id: 2, 
		Backplane: Fabric1, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:90:77:65
		IP Source: static


	Network Interfaces:
		Id: 1, 
		Backplane: Base1, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:90:77:66
		IP Source: dhcp


		Id: 2, 
		Backplane: Fabric2, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:90:77:67
		IP Source: static

================================

*******************************
Original JSON string
*******************************
{ "name": "Platform #1", "number": "1", "chassis": "ms2900", "health": "Green", "fans":[ {"number": "1", "name": "Fan 1", "type": "fan", "health": "Green", "rpm": "5698","alarm": {"alarmlevel": "None"}, "LedIdentify": {"status": "off"}, "hotswapStatus":{"state": "M4", "text": "Active"}}, {"number": "2", "name": "Fan 2", "type": "fan", "health": "Green", "rpm": "5698","alarm": {"alarmlevel": "None"}, "LedIdentify": {"status": "off"}, "hotswapStatus":{"state": "M4", "text": "Active"}}, {"number": "3", "name": "Fan 3", "type": "fan", "health": "Green", "rpm": "5775","alarm": {"alarmlevel": "None"}, "LedIdentify": {"status": "off"}, "hotswapStatus":{"state": "M4", "text": "Active"}}, {"number": "4", "name": "Fan 4", "type": "fan", "health": "Green", "rpm": "5852","alarm": {"alarmlevel": "None"}, "LedIdentify": {"status": "off"}, "hotswapStatus":{"state": "M4", "text": "Active"}}, {"number": "5", "name": "Fan 5", "type": "fan", "health": "Green", "rpm": "5852","alarm": {"alarmlevel": "None"}, "LedIdentify": {"status": "off"}, "hotswapStatus":{"state": "M4", "text": "Active"}} ], "type": "platform", "components": [{"number": "10", "name": "HubNode 1", "health": "Green", "fruInfo": {"mfgDate": "Mon Jun 27 13:19:00 2016", "boardMfg": "Kontron", "boardProductName": "MSH8900", "boardProductPart": "T4301X_2-X", "boardSerialNumber": "9013123954"},"hotswapStatus":{"state": "M4", "text": "Active"},"type":"hubnode", "HubNodeFeatures":{"SwitchSpeedSupport": "1", "PortModeSupport": "0"}, "versions" : [{ "name" : "BMC", "major" : "3", "minor" : "18", "revision" : "093413FB"},{ "name" : "FPGA", "major" : "2", "minor" : "04", "revision" : "00000000"}],"model": "MSH8900", "isUpdating" : "0", "managementIP": "10.24.46.169", "managementMAC": "00:a0:a5:89:db:4b", "alarm": {"alarmlevel": "None", "sensors":[]}, "LedIdentify": {"status": "off"}, "components": [{ "description": "Switch 1", "number": "1", "hotswapStatus":{"state": "M4", "text": "Active"}, "networkInterfaces": [{ "id": "1", "backplane": "Management", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:89:db:2c"}]}], "status": "Standby"}, {"number": "11", "name": "HubNode 2", "health": "Green", "fruInfo": {"mfgDate": "Mon Jun 27 13:52:00 2016", "boardMfg": "Kontron", "boardProductName": "MSH8900", "boardProductPart": "T4301X_2-X", "boardSerialNumber": "9013123965"},"hotswapStatus":{"state": "M4", "text": "Active"},"type":"hubnode", "HubNodeFeatures":{"SwitchSpeedSupport": "1", "PortModeSupport": "0"}, "versions" : [{ "name" : "BMC", "major" : "3", "minor" : "18", "revision" : "093413FB"},{ "name" : "FPGA", "major" : "2", "minor" : "04", "revision" : "00000000"}],"model": "MSH8900", "isUpdating" : "0", "managementIP": "10.24.46.187", "managementMAC": "00:a0:a5:90:d3:b3", "alarm": {"alarmlevel": "None", "sensors":[]}, "LedIdentify": {"status": "off"}, "components": [{ "description": "Switch 2", "number": "1", "hotswapStatus":{"state": "M4", "text": "Active"}, "networkInterfaces": [{ "id": "1", "backplane": "Management", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:90:d3:94"}]}], "status": "Active"}, {"number": "1", "name": "Node 1", "health": "Green", "fruInfo": {"mfgDate": "Mon May 30 17:40:00 2016", "boardMfg": "Kontron", "boardProductName": "4005", "boardProductPart": "T4005CXXX_2-CXX", "boardSerialNumber": "9013110481"},"hotswapStatus":{"state": "M4", "text": "Active"},"type":"node", "versions" : [{ "name" : "BMC", "major" : "2", "minor" : "18", "revision" : "08FA45E0"},{ "name" : "FPGA", "major" : "2", "minor" : "12", "revision" : "00000000"},{ "name" : "BIOS", "major" : "2", "minor" : "14", "revision" : "00000000"}],"model": "MSP8022", "isUpdating" : "0", "managementIP": "10.24.46.144", "managementMAC": "00:a0:a5:90:77:1e", "alarm": {"alarmlevel": "None", "sensors":[]}, "LedIdentify": {"status": "off"}, "components": [{ "description": "Payload1       ", "number": "1", "hotswapStatus":{"state": "M4", "text": "Active"}, "networkInterfaces": [{ "id": "1", "backplane": "Base2", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "dhcp", "mac": "00:a0:a5:90:77:1a"}, { "id": "2", "backplane": "Fabric1", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:90:77:1b"}]}, { "description": "Payload2       ", "number": "2", "hotswapStatus":{"state": "M4", "text": "Active"}, "networkInterfaces": [{ "id": "1", "backplane": "Base1", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "dhcp", "mac": "00:a0:a5:90:77:1c"}, { "id": "2", "backplane": "Fabric2", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:90:77:1d"}]}] }, {"number": "2", "name": "Node 2", "health": "Green", "fruInfo": {"mfgDate": "Mon May 30 17:40:00 2016", "boardMfg": "Kontron", "boardProductName": "4005", "boardProductPart": "T4005CXXX_2-CXX", "boardSerialNumber": "9013101130"},"hotswapStatus":{"state": "M4", "text": "Active"},"type":"node", "versions" : [{ "name" : "BMC", "major" : "2", "minor" : "18", "revision" : "08FA45E0"},{ "name" : "FPGA", "major" : "2", "minor" : "12", "revision" : "00000000"},{ "name" : "BIOS", "major" : "2", "minor" : "14", "revision" : "00000000"}],"model": "MSP8022", "isUpdating" : "0", "managementIP": "10.24.46.152", "managementMAC": "00:a0:a5:88:7c:74", "alarm": {"alarmlevel": "None", "sensors":[]}, "LedIdentify": {"status": "off"}, "components": [{ "description": "Payload1       ", "number": "1", "hotswapStatus":{"state": "M4", "text": "Active"}, "networkInterfaces": [{ "id": "1", "backplane": "Base2", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "dhcp", "mac": "00:a0:a5:88:7c:70"}, { "id": "2", "backplane": "Fabric1", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:88:7c:71"}]}, { "description": "Payload2       ", "number": "2", "hotswapStatus":{"state": "M4", "text": "Active"}, "networkInterfaces": [{ "id": "1", "backplane": "Base1", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "dhcp", "mac": "00:a0:a5:88:7c:72"}, { "id": "2", "backplane": "Fabric2", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:88:7c:73"}]}] }, {"number": "3", "name": "Node 3", "health": "Green", "fruInfo": {"mfgDate": "Mon May 30 18:10:00 2016", "boardMfg": "Kontron", "boardProductName": "4005", "boardProductPart": "T4005CXXX_2-CXX", "boardSerialNumber": "9013110525"},"hotswapStatus":{"state": "M4", "text": "Active"},"type":"node", "versions" : [{ "name" : "BMC", "major" : "2", "minor" : "18", "revision" : "08FA45E0"},{ "name" : "FPGA", "major" : "2", "minor" : "12", "revision" : "00000000"},{ "name" : "BIOS", "major" : "2", "minor" : "14", "revision" : "00000000"}],"model": "MSP8022", "isUpdating" : "0", "managementIP": "10.24.46.151", "managementMAC": "00:a0:a5:89:33:b6", "alarm": {"alarmlevel": "None", "sensors":[]}, "LedIdentify": {"status": "off"}, "components": [{ "description": "Payload1       ", "number": "1", "hotswapStatus":{"state": "M4", "text": "Active"}, "networkInterfaces": [{ "id": "1", "backplane": "Base2", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "dhcp", "mac": "00:a0:a5:89:33:b2"}, { "id": "2", "backplane": "Fabric1", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:89:33:b3"}]}, { "description": "Payload2       ", "number": "2", "hotswapStatus":{"state": "M4", "text": "Active"}, "networkInterfaces": [{ "id": "1", "backplane": "Base1", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "dhcp", "mac": "00:a0:a5:89:33:b4"}, { "id": "2", "backplane": "Fabric2", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:89:33:b5"}]}] }, {"number": "4", "name": "Node 4", "health": "Green", "fruInfo": {"mfgDate": "Mon May 30 19:17:00 2016", "boardMfg": "Kontron", "boardProductName": "4005", "boardProductPart": "T4005CXXX_2-CXX", "boardSerialNumber": "9013110552"},"hotswapStatus":{"state": "M4", "text": "Active"},"type":"node", "versions" : [{ "name" : "BMC", "major" : "2", "minor" : "18", "revision" : "08FA45E0"},{ "name" : "FPGA", "major" : "2", "minor" : "12", "revision" : "00000000"},{ "name" : "BIOS", "major" : "2", "minor" : "14", "revision" : "00000000"}],"model": "MSP8022", "isUpdating" : "0", "managementIP": "10.24.46.160", "managementMAC": "00:a0:a5:90:8a:ce", "alarm": {"alarmlevel": "None", "sensors":[]}, "LedIdentify": {"status": "off"}, "components": [{ "description": "Payload1       ", "number": "1", "hotswapStatus":{"state": "M4", "text": "Active"}, "networkInterfaces": [{ "id": "1", "backplane": "Base2", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "dhcp", "mac": "00:a0:a5:90:8a:ca"}, { "id": "2", "backplane": "Fabric1", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:90:8a:cb"}]}, { "description": "Payload2       ", "number": "2", "hotswapStatus":{"state": "M4", "text": "Active"}, "networkInterfaces": [{ "id": "1", "backplane": "Base1", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "dhcp", "mac": "00:a0:a5:90:8a:cc"}, { "id": "2", "backplane": "Fabric2", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:90:8a:cd"}]}] }, {"number": "5", "name": "Node 5", "health": "Green", "fruInfo": {"mfgDate": "Mon May 30 19:30:00 2016", "boardMfg": "Kontron", "boardProductName": "4005", "boardProductPart": "T4005CXXX_2-CXX", "boardSerialNumber": "9013110526"},"hotswapStatus":{"state": "M4", "text": "Active"},"type":"node", "versions" : [{ "name" : "BMC", "major" : "2", "minor" : "18", "revision" : "08FA45E0"},{ "name" : "FPGA", "major" : "2", "minor" : "12", "revision" : "00000000"},{ "name" : "BIOS", "major" : "2", "minor" : "14", "revision" : "00000000"}],"model": "MSP8022", "isUpdating" : "0", "managementIP": "10.24.46.156", "managementMAC": "00:a0:a5:90:8b:52", "alarm": {"alarmlevel": "None", "sensors":[]}, "LedIdentify": {"status": "off"}, "components": [{ "description": "Payload1       ", "number": "1", "hotswapStatus":{"state": "M4", "text": "Active"}, "networkInterfaces": [{ "id": "1", "backplane": "Base2", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "dhcp", "mac": "00:a0:a5:90:8b:4e"}, { "id": "2", "backplane": "Fabric1", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:90:8b:4f"}]}, { "description": "Payload2       ", "number": "2", "hotswapStatus":{"state": "M4", "text": "Active"}, "networkInterfaces": [{ "id": "1", "backplane": "Base1", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "dhcp", "mac": "00:a0:a5:90:8b:50"}, { "id": "2", "backplane": "Fabric2", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:90:8b:51"}]}] }, {"number": "6", "name": "Node 6", "health": "Green", "fruInfo": {"mfgDate": "Mon May 30 19:26:00 2016", "boardMfg": "Kontron", "boardProductName": "4005", "boardProductPart": "T4005CXXX_2-CXX", "boardSerialNumber": "9013110491"},"hotswapStatus":{"state": "M4", "text": "Active"},"type":"node", "versions" : [{ "name" : "BMC", "major" : "2", "minor" : "18", "revision" : "08FA45E0"},{ "name" : "FPGA", "major" : "2", "minor" : "12", "revision" : "00000000"},{ "name" : "BIOS", "major" : "2", "minor" : "14", "revision" : "00000000"}],"model": "MSP8022", "isUpdating" : "0", "managementIP": "10.24.46.139", "managementMAC": "00:a0:a5:90:77:80", "alarm": {"alarmlevel": "None", "sensors":[]}, "LedIdentify": {"status": "off"}, "components": [{ "description": "Payload1       ", "number": "1", "hotswapStatus":{"state": "M4", "text": "Active"}, "networkInterfaces": [{ "id": "1", "backplane": "Base2", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "dhcp", "mac": "00:a0:a5:90:77:7c"}, { "id": "2", "backplane": "Fabric1", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:90:77:7d"}]}, { "description": "Payload2       ", "number": "2", "hotswapStatus":{"state": "M4", "text": "Active"}, "networkInterfaces": [{ "id": "1", "backplane": "Base1", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "dhcp", "mac": "00:a0:a5:90:77:7e"}, { "id": "2", "backplane": "Fabric2", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:90:77:7f"}]}] }, {"number": "7", "name": "Node 7", "health": "Green", "fruInfo": {"mfgDate": "Mon May 30 17:40:00 2016", "boardMfg": "Kontron", "boardProductName": "4005", "boardProductPart": "T4005CXXX_2-CXX", "boardSerialNumber": "9013113468"},"hotswapStatus":{"state": "M4", "text": "Active"},"type":"node", "versions" : [{ "name" : "BMC", "major" : "2", "minor" : "18", "revision" : "08FA45E0"},{ "name" : "FPGA", "major" : "2", "minor" : "12", "revision" : "00000000"},{ "name" : "BIOS", "major" : "2", "minor" : "14", "revision" : "00000000"}],"model": "MSP8022", "isUpdating" : "0", "managementIP": "10.24.46.192", "managementMAC": "00:a0:a5:90:8a:e6", "alarm": {"alarmlevel": "None", "sensors":[]}, "LedIdentify": {"status": "off"}, "components": [{ "description": "Payload1       ", "number": "1", "hotswapStatus":{"state": "M4", "text": "Active"}, "networkInterfaces": [{ "id": "1", "backplane": "Base2", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "dhcp", "mac": "00:a0:a5:90:8a:e2"}, { "id": "2", "backplane": "Fabric1", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:90:8a:e3"}]}, { "description": "Payload2       ", "number": "2", "hotswapStatus":{"state": "M4", "text": "Active"}, "networkInterfaces": [{ "id": "1", "backplane": "Base1", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "dhcp", "mac": "00:a0:a5:90:8a:e4"}, { "id": "2", "backplane": "Fabric2", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:90:8a:e5"}]}] }, {"number": "8", "name": "Node 8", "health": "Green", "fruInfo": {"mfgDate": "Mon May 30 18:08:00 2016", "boardMfg": "Kontron", "boardProductName": "4005", "boardProductPart": "T4005CXXX_2-CXX", "boardSerialNumber": "9013110503"},"hotswapStatus":{"state": "M4", "text": "Active"},"type":"node", "versions" : [{ "name" : "BMC", "major" : "2", "minor" : "18", "revision" : "08FA45E0"},{ "name" : "FPGA", "major" : "2", "minor" : "12", "revision" : "00000000"},{ "name" : "BIOS", "major" : "2", "minor" : "14", "revision" : "00000000"}],"model": "MSP8022", "isUpdating" : "0", "managementIP": "10.24.46.125", "managementMAC": "00:a0:a5:89:0f:f6", "alarm": {"alarmlevel": "None", "sensors":[]}, "LedIdentify": {"status": "off"}, "components": [{ "description": "Payload1       ", "number": "1", "hotswapStatus":{"state": "M4", "text": "Active"}, "networkInterfaces": [{ "id": "1", "backplane": "Base2", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "dhcp", "mac": "00:a0:a5:89:0f:f2"}, { "id": "2", "backplane": "Fabric1", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:89:0f:f3"}]}, { "description": "Payload2       ", "number": "2", "hotswapStatus":{"state": "M4", "text": "Active"}, "networkInterfaces": [{ "id": "1", "backplane": "Base1", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "dhcp", "mac": "00:a0:a5:89:0f:f4"}, { "id": "2", "backplane": "Fabric2", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:89:0f:f5"}]}] }, {"number": "9", "name": "Node 9", "health": "Green", "fruInfo": {"mfgDate": "Mon May 30 18:07:00 2016", "boardMfg": "Kontron", "boardProductName": "4005", "boardProductPart": "T4005CXXX_2-CXX", "boardSerialNumber": "9013110440"},"hotswapStatus":{"state": "M4", "text": "Active"},"type":"node", "versions" : [{ "name" : "BMC", "major" : "2", "minor" : "18", "revision" : "08FA45E0"},{ "name" : "FPGA", "major" : "2", "minor" : "12", "revision" : "00000000"},{ "name" : "BIOS", "major" : "2", "minor" : "14", "revision" : "00000000"}],"model": "MSP8022", "isUpdating" : "0", "managementIP": "10.24.46.133", "managementMAC": "00:a0:a5:90:77:68", "alarm": {"alarmlevel": "None", "sensors":[]}, "LedIdentify": {"status": "off"}, "components": [{ "description": "Payload1       ", "number": "1", "hotswapStatus":{"state": "M4", "text": "Active"}, "networkInterfaces": [{ "id": "1", "backplane": "Base2", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "dhcp", "mac": "00:a0:a5:90:77:64"}, { "id": "2", "backplane": "Fabric1", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:90:77:65"}]}, { "description": "Payload2       ", "number": "2", "hotswapStatus":{"state": "M4", "text": "Active"}, "networkInterfaces": [{ "id": "1", "backplane": "Base1", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "dhcp", "mac": "00:a0:a5:90:77:66"}, { "id": "2", "backplane": "Fabric2", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:90:77:67"}]}] }, { "name": "PSU", "components": [{"id": "PSU1", "number": "1", "name": "Power Supply 1", "health": "Green", "type": "psu", "hotswapStatus":{"state": "M4", "text": "Active"},"alarm": {"alarmlevel": "None"}, "tempInlet": "24.00", "tempOutlet": "34.00", "vIn": "204.00", "powerOut": "328", "powerScale": "1400","peakConsumption": "392", "averageConsumption": "328"},{"id": "PSU2", "number": "2", "name": "Power Supply 2", "health": "Green", "type": "psu", "hotswapStatus":{"state": "M4", "text": "Active"},"alarm": {"alarmlevel": "None"}, "tempInlet": "24.00", "tempOutlet": "34.00", "vIn": "204.00", "powerOut": "320", "powerScale": "1400","peakConsumption": "384", "averageConsumption": "320"}]}], "switchOID": {"oid": "1.3.6.1.4.1.6603"}, "alarm": {"alarmlevel": "None",  "components" : [ {"nodes" : [] } , {"psu" : [] }, {"fans" : [] }], "text": ""}, "LedIdentify": {"status": "off"}}