System informations
*******************************
Name: SYMKLOUD
chassis: ms2900
Health: Healthy
*******************************
Fans: 
*******************************
Fan 1: 
	Present :true
	Status :Healthy
	8393 RPM
Fan 2: 
	Present :true
	Status :Healthy
	8316 RPM
Fan 3: 
	Present :true
	Status :Healthy
	8470 RPM
Fan 4: 
	Present :true
	Status :Healthy
	8393 RPM
Fan 5: 
	Present :true
	Status :Healthy
	8316 RPM


*******************************
PSU: 
*******************************
Name: PSU 1
Health: Healthy
Health Details: No details available
Hotswap Status: Active
FRU: Informations are invalid

Name: PSU 2
Health: Healthy
Health Details: No details available
Hotswap Status: Active
FRU: Informations are invalid



*******************************
HubNodes
*******************************

================================
Name: HubNode 1
Health: Healthy
Health Details: 
        | Sensor ID | Sensor Name      | Value   | Health                |
         ---------------------------------------------------------------- 
        | 0x0b      | Temp On-Board    | 30.00   | Healthy               |
        | 0x0c      | Temp Eth Switch  | 28.00   | Healthy               |
        | 0x0d      | Temp Quad Phy    | 35.00   | Healthy               |
        | 0x0e      | Temp Inlet       | 22.00   | Healthy               |
        | 0x0f      | Temp Phy 10G     | 54.00   | Healthy               |
        | 0x10      | Vcc +12V In      | 12.06   | Healthy               |
        | 0x11      | Vcc +5V SUS      | 5.03    | Healthy               |
        | 0x12      | Vcc +3.3V SUS    | 3.31    | Healthy               |
        | 0x13      | Vcc +1.8V SUS    | 1.78    | Healthy               |
        | 0x14      | Vcc +1.5V SUS    | 1.50    | Healthy               |
        | 0x15      | Vcc +1.25V SUS   | 1.24    | Healthy               |
        | 0x16      | Vcc +1.2V SUS    | 1.18    | Healthy               |
        | 0x17      | Vcc +0.75V SUS   | 0.75    | Healthy               |
        | 0x18      | Vcc +3.3V        | 3.29    | Healthy               |
        | 0x19      | Vcc +2.5V        | 2.46    | Healthy               |
        | 0x1a      | Vcc +1.8V        | 1.78    | Healthy               |
        | 0x1b      | Vcc +1.2V        | 1.21    | Healthy               |
        | 0x1c      | Vcc +1.0V        | 1.01    | Healthy               |
        | 0x1d      | Vbat +3V         | 3.07    | Healthy               |
        | 0x3f      | Power Good Latch | 0x8001  | Healthy               |
        | 0x40      | FPGA RW Status   | 0x8002  | Healthy               |
        | 0x41      | FPGA Heartbeat   | 0x8002  | Healthy               |
        | 0x48      | ShMC Redun State | 0x8002  | Healthy               |
Hotswap Status: Active
Product name: MSH8900
Part number: T4301X_2-X
Serial number: 9016242282
Manufacturing date: Wed Mar 14 13:08:00 2018
Type: HubNode
Status: Active
Model: MSH8900
HPM versions:
	BMC: 3.18.093413FB
	FPGA: 2.4.00000000
Management Network:
        Management MAC: 00:a0:a5:c1:27:99
        IP Source: dhcp
        IP: 10.24.58.112
        Subnet: 255.255.255.0
        Gateway: 10.24.58.3
        VLAN: FFD
Payload IPs :
	Network Interfaces:
		Id: 1, 
		Backplane: Management, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:c1:27:7a
		IP Source: static

================================

================================
Name: HubNode 2
Health: Healthy
Health Details: 
        | Sensor ID | Sensor Name      | Value   | Health                |
         ---------------------------------------------------------------- 
        | 0x0b      | Temp On-Board    | 28.00   | Healthy               |
        | 0x0c      | Temp Eth Switch  | 27.00   | Healthy               |
        | 0x0d      | Temp Quad Phy    | 34.00   | Healthy               |
        | 0x0e      | Temp Inlet       | 22.00   | Healthy               |
        | 0x0f      | Temp Phy 10G     | 51.00   | Healthy               |
        | 0x10      | Vcc +12V In      | 12.01   | Healthy               |
        | 0x11      | Vcc +5V SUS      | 5.03    | Healthy               |
        | 0x12      | Vcc +3.3V SUS    | 3.31    | Healthy               |
        | 0x13      | Vcc +1.8V SUS    | 1.79    | Healthy               |
        | 0x14      | Vcc +1.5V SUS    | 1.51    | Healthy               |
        | 0x15      | Vcc +1.25V SUS   | 1.24    | Healthy               |
        | 0x16      | Vcc +1.2V SUS    | 1.19    | Healthy               |
        | 0x17      | Vcc +0.75V SUS   | 0.75    | Healthy               |
        | 0x18      | Vcc +3.3V        | 3.29    | Healthy               |
        | 0x19      | Vcc +2.5V        | 2.48    | Healthy               |
        | 0x1a      | Vcc +1.8V        | 1.78    | Healthy               |
        | 0x1b      | Vcc +1.2V        | 1.21    | Healthy               |
        | 0x1c      | Vcc +1.0V        | 1.01    | Healthy               |
        | 0x1d      | Vbat +3V         | 3.06    | Healthy               |
        | 0x3f      | Power Good Latch | 0x8001  | Healthy               |
        | 0x40      | FPGA RW Status   | 0x8002  | Healthy               |
        | 0x41      | FPGA Heartbeat   | 0x8002  | Healthy               |
        | 0x48      | ShMC Redun State | 0x8008  | Healthy               |
Hotswap Status: Active
Product name: MSH8900
Part number: T4301X_2-X
Serial number: 9016242314
Manufacturing date: Wed Mar 14 13:08:00 2018
Type: HubNode
Status: Standby
Model: MSH8900
HPM versions:
	BMC: 3.18.093413FB
	FPGA: 2.4.00000000
Management Network:
        Management MAC: 00:a0:a5:c1:31:3d
        IP Source: dhcp
        IP: 10.24.58.123
        Subnet: 255.255.255.0
        Gateway: 10.24.58.3
        VLAN: FFD
Payload IPs :
	Network Interfaces:
		Id: 1, 
		Backplane: Management, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:c1:31:1e
		IP Source: static

================================

*******************************
Nodes
*******************************

================================
SLOT #1
================================
Name: Node 1
Health: Healthy
Health Details: 
        | Sensor ID | Sensor Name      | Value   | Health                |
         ---------------------------------------------------------------- 
        | 0x0e      | Vcc +12V SUS     | 11.95   | Healthy               |
        | 0x0f      | Vcc +5V SUS      | 4.98    | Healthy               |
        | 0x10      | Vcc +2.5V SUS    | 2.49    | Healthy               |
        | 0x11      | Vcc +1.8V SUS    | 1.80    | Healthy               |
        | 0x12      | Vcc +1.5V SUS    | 1.50    | Healthy               |
        | 0x13      | Vcc +1.25V SUS   | 1.26    | Healthy               |
        | 0x14      | Vcc +0.75V SUS   | 0.74    | Healthy               |
        | 0x04      | Temp Inlet       | 28.00   | Healthy               |
        | 0x05      | Temp Outlet      | 46.00   | Healthy               |
        | 0x07      | Temp BMC         | 47.00   | Healthy               |
        | 0x08      | Temp CPU 1       | 57.00   | Healthy               |
        | 0x09      | Temp CPU 2       | 47.00   | Healthy               |
Hotswap Status: Active
Product name: 4009
Part number: 1062-0224
Serial number: 9016252652
Manufacturing date: Wed Mar 14 12:41:00 2018
Type: Node
Model: MSP805x
HPM versions:
	BMC: 1.3.091805DF
	FPGA: 1.0.00000000
	BIOS: 1.1.0916DD5E
Management Network:
        Management MAC: 00:a0:a5:c2:ca:e2
        IP Source: dhcp
        IP: 10.24.58.146
        Subnet: 255.255.255.0
        Gateway: 10.24.58.3
        VLAN: FFD
Payload IPs :
	Network Interfaces:
		Id: 1, 
		Backplane: Base2, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:c2:ca:dc
		IP Source: static


		Id: 2, 
		Backplane: Fabric1p1, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:c2:ca:dd
		IP Source: static


		Id: 3, 
		Backplane: Fabric2p2, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:c2:ca:de
		IP Source: static


	Network Interfaces:
		Id: 1, 
		Backplane: Base1, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:c2:ca:df
		IP Source: static


		Id: 2, 
		Backplane: Fabric1p2, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:c2:ca:e0
		IP Source: static


		Id: 3, 
		Backplane: Fabric2p1, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:c2:ca:e1
		IP Source: static

================================

================================
SLOT #2
================================
Name: Node 2
Health: Healthy
Health Details: 
        | Sensor ID | Sensor Name      | Value   | Health                |
         ---------------------------------------------------------------- 
        | 0x0e      | Vcc +12V SUS     | 11.95   | Healthy               |
        | 0x0f      | Vcc +5V SUS      | 5.05    | Healthy               |
        | 0x10      | Vcc +2.5V SUS    | 2.48    | Healthy               |
        | 0x11      | Vcc +1.8V SUS    | 1.79    | Healthy               |
        | 0x12      | Vcc +1.5V SUS    | 1.47    | Healthy               |
        | 0x13      | Vcc +1.25V SUS   | 1.25    | Healthy               |
        | 0x14      | Vcc +0.75V SUS   | 0.74    | Healthy               |
        | 0x04      | Temp Inlet       | 26.00   | Healthy               |
        | 0x05      | Temp Outlet      | 45.00   | Healthy               |
        | 0x07      | Temp BMC         | 45.00   | Healthy               |
        | 0x08      | Temp CPU 1       | 57.00   | Healthy               |
        | 0x09      | Temp CPU 2       | 43.00   | Healthy               |
Hotswap Status: Active
Product name: 4009
Part number: 1062-0224
Serial number: 9016240704
Manufacturing date: Wed Mar 14 12:42:00 2018
Type: Node
Model: MSP805x
HPM versions:
	BMC: 1.3.091805DF
	FPGA: 1.0.00000000
	BIOS: 1.1.0916DD5E
Management Network:
        Management MAC: 00:a0:a5:bf:24:30
        IP Source: dhcp
        IP: 10.24.58.132
        Subnet: 255.255.255.0
        Gateway: 10.24.58.3
        VLAN: FFD
Payload IPs :
	Network Interfaces:
		Id: 1, 
		Backplane: Base2, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:bf:24:2a
		IP Source: static


		Id: 2, 
		Backplane: Fabric1p1, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:bf:24:2b
		IP Source: static


		Id: 3, 
		Backplane: Fabric2p2, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:bf:24:2c
		IP Source: static


	Network Interfaces:
		Id: 1, 
		Backplane: Base1, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:bf:24:2d
		IP Source: static


		Id: 2, 
		Backplane: Fabric1p2, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:bf:24:2e
		IP Source: static


		Id: 3, 
		Backplane: Fabric2p1, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:bf:24:2f
		IP Source: static

================================

================================
SLOT #3
================================
Name: Node 3
Health: Healthy
Health Details: 
        | Sensor ID | Sensor Name      | Value   | Health                |
         ---------------------------------------------------------------- 
        | 0x0e      | Vcc +12V SUS     | 11.95   | Healthy               |
        | 0x0f      | Vcc +5V SUS      | 5.05    | Healthy               |
        | 0x10      | Vcc +2.5V SUS    | 2.48    | Healthy               |
        | 0x11      | Vcc +1.8V SUS    | 1.81    | Healthy               |
        | 0x12      | Vcc +1.5V SUS    | 1.49    | Healthy               |
        | 0x13      | Vcc +1.25V SUS   | 1.24    | Healthy               |
        | 0x14      | Vcc +0.75V SUS   | 0.74    | Healthy               |
        | 0x04      | Temp Inlet       | 25.00   | Healthy               |
        | 0x05      | Temp Outlet      | 43.00   | Healthy               |
        | 0x07      | Temp BMC         | 44.00   | Healthy               |
        | 0x08      | Temp CPU 1       | 55.00   | Healthy               |
        | 0x09      | Temp CPU 2       | 42.00   | Healthy               |
Hotswap Status: Active
Product name: 4009
Part number: 1062-0224
Serial number: 9016240691
Manufacturing date: Wed Mar 14 14:20:00 2018
Type: Node
Model: MSP805x
HPM versions:
	BMC: 1.3.091805DF
	FPGA: 1.0.00000000
	BIOS: 1.1.0916DD5E
Management Network:
        Management MAC: 00:a0:a5:bf:23:74
        IP Source: dhcp
        IP: 10.24.58.166
        Subnet: 255.255.255.0
        Gateway: 10.24.58.3
        VLAN: FFD
Payload IPs :
	Network Interfaces:
		Id: 1, 
		Backplane: Base2, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:bf:23:6e
		IP Source: static


		Id: 2, 
		Backplane: Fabric1p1, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:bf:23:6f
		IP Source: static


		Id: 3, 
		Backplane: Fabric2p2, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:bf:23:70
		IP Source: static


	Network Interfaces:
		Id: 1, 
		Backplane: Base1, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:bf:23:71
		IP Source: static


		Id: 2, 
		Backplane: Fabric1p2, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:bf:23:72
		IP Source: static


		Id: 3, 
		Backplane: Fabric2p1, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:bf:23:73
		IP Source: static

================================

================================
SLOT #4
================================
Name: Node 4
Health: Healthy
Health Details: 
        | Sensor ID | Sensor Name      | Value   | Health                |
         ---------------------------------------------------------------- 
        | 0x0e      | Vcc +12V SUS     | 11.95   | Healthy               |
        | 0x0f      | Vcc +5V SUS      | 4.98    | Healthy               |
        | 0x10      | Vcc +2.5V SUS    | 2.48    | Healthy               |
        | 0x11      | Vcc +1.8V SUS    | 1.81    | Healthy               |
        | 0x12      | Vcc +1.5V SUS    | 1.47    | Healthy               |
        | 0x13      | Vcc +1.25V SUS   | 1.24    | Healthy               |
        | 0x14      | Vcc +0.75V SUS   | 0.75    | Healthy               |
        | 0x04      | Temp Inlet       | 25.00   | Healthy               |
        | 0x05      | Temp Outlet      | 45.00   | Healthy               |
        | 0x07      | Temp BMC         | 47.00   | Healthy               |
        | 0x08      | Temp CPU 1       | 59.00   | Healthy               |
        | 0x09      | Temp CPU 2       | 46.00   | Healthy               |
Hotswap Status: Active
Product name: 4009
Part number: 1062-0224
Serial number: 9016252749
Manufacturing date: Wed Mar 14 14:17:00 2018
Type: Node
Model: MSP805x
HPM versions:
	BMC: 1.3.091805DF
	FPGA: 1.0.00000000
	BIOS: 1.1.0916DD5E
Management Network:
        Management MAC: 00:a0:a5:c2:ce:2c
        IP Source: dhcp
        IP: 10.24.58.192
        Subnet: 255.255.255.0
        Gateway: 10.24.58.3
        VLAN: FFD
Payload IPs :
	Network Interfaces:
		Id: 1, 
		Backplane: Base2, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:c2:ce:26
		IP Source: static


		Id: 2, 
		Backplane: Fabric1p1, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:c2:ce:27
		IP Source: static


		Id: 3, 
		Backplane: Fabric2p2, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:c2:ce:28
		IP Source: static


	Network Interfaces:
		Id: 1, 
		Backplane: Base1, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:c2:ce:29
		IP Source: static


		Id: 2, 
		Backplane: Fabric1p2, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:c2:ce:2a
		IP Source: static


		Id: 3, 
		Backplane: Fabric2p1, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:c2:ce:2b
		IP Source: static

================================

================================
SLOT #5
================================
Name: Node 5
Health: Healthy
Health Details: 
        | Sensor ID | Sensor Name      | Value   | Health                |
         ---------------------------------------------------------------- 
        | 0x0e      | Vcc +12V SUS     | 11.95   | Healthy               |
        | 0x0f      | Vcc +5V SUS      | 4.98    | Healthy               |
        | 0x10      | Vcc +2.5V SUS    | 2.48    | Healthy               |
        | 0x11      | Vcc +1.8V SUS    | 1.80    | Healthy               |
        | 0x12      | Vcc +1.5V SUS    | 1.49    | Healthy               |
        | 0x13      | Vcc +1.25V SUS   | 1.25    | Healthy               |
        | 0x14      | Vcc +0.75V SUS   | 0.74    | Healthy               |
        | 0x04      | Temp Inlet       | 25.00   | Healthy               |
        | 0x05      | Temp Outlet      | 45.00   | Healthy               |
        | 0x07      | Temp BMC         | 45.00   | Healthy               |
        | 0x08      | Temp CPU 1       | 58.00   | Healthy               |
        | 0x09      | Temp CPU 2       | 46.00   | Healthy               |
Hotswap Status: Active
Product name: 4009
Part number: 1062-0224
Serial number: 9016252735
Manufacturing date: Wed Mar 14 17:04:00 2018
Type: Node
Model: MSP805x
HPM versions:
	BMC: 1.3.091805DF
	FPGA: 1.0.00000000
	BIOS: 1.1.0916DD5E
Management Network:
        Management MAC: 00:a0:a5:c2:ca:aa
        IP Source: dhcp
        IP: 10.24.58.140
        Subnet: 255.255.255.0
        Gateway: 10.24.58.3
        VLAN: FFD
Payload IPs :
	Network Interfaces:
		Id: 1, 
		Backplane: Base2, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:c2:ca:a4
		IP Source: static


		Id: 2, 
		Backplane: Fabric1p1, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:c2:ca:a5
		IP Source: static


		Id: 3, 
		Backplane: Fabric2p2, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:c2:ca:a6
		IP Source: static


	Network Interfaces:
		Id: 1, 
		Backplane: Base1, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:c2:ca:a7
		IP Source: static


		Id: 2, 
		Backplane: Fabric1p2, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:c2:ca:a8
		IP Source: static


		Id: 3, 
		Backplane: Fabric2p1, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:c2:ca:a9
		IP Source: static

================================

================================
SLOT #6
================================
Name: Node 6
Health: Healthy
Health Details: 
        | Sensor ID | Sensor Name      | Value   | Health                |
         ---------------------------------------------------------------- 
        | 0x0e      | Vcc +12V SUS     | 12.01   | Healthy               |
        | 0x0f      | Vcc +5V SUS      | 5.05    | Healthy               |
        | 0x10      | Vcc +2.5V SUS    | 2.47    | Healthy               |
        | 0x11      | Vcc +1.8V SUS    | 1.80    | Healthy               |
        | 0x12      | Vcc +1.5V SUS    | 1.50    | Healthy               |
        | 0x13      | Vcc +1.25V SUS   | 1.24    | Healthy               |
        | 0x14      | Vcc +0.75V SUS   | 0.76    | Healthy               |
        | 0x04      | Temp Inlet       | 25.00   | Healthy               |
        | 0x05      | Temp Outlet      | 44.00   | Healthy               |
        | 0x07      | Temp BMC         | 44.00   | Healthy               |
        | 0x08      | Temp CPU 1       | 55.00   | Healthy               |
        | 0x09      | Temp CPU 2       | 44.00   | Healthy               |
Hotswap Status: Active
Product name: 4009
Part number: 1062-0224
Serial number: 9016240767
Manufacturing date: Wed Mar 14 17:04:00 2018
Type: Node
Model: MSP805x
HPM versions:
	BMC: 1.3.091805DF
	FPGA: 1.0.00000000
	BIOS: 1.1.0916DD5E
Management Network:
        Management MAC: 00:a0:a5:be:93:b4
        IP Source: dhcp
        IP: 10.24.58.160
        Subnet: 255.255.255.0
        Gateway: 10.24.58.3
        VLAN: FFD
Payload IPs :
	Network Interfaces:
		Id: 1, 
		Backplane: Base2, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:be:93:ae
		IP Source: static


		Id: 2, 
		Backplane: Fabric1p1, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:be:93:af
		IP Source: static


		Id: 3, 
		Backplane: Fabric2p2, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:be:93:b0
		IP Source: static


	Network Interfaces:
		Id: 1, 
		Backplane: Base1, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:be:93:b1
		IP Source: static


		Id: 2, 
		Backplane: Fabric1p2, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:be:93:b2
		IP Source: static


		Id: 3, 
		Backplane: Fabric2p1, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:be:93:b3
		IP Source: static

================================

================================
SLOT #7
================================
Name: Node 7
Health: Healthy
Health Details: 
        | Sensor ID | Sensor Name      | Value   | Health                |
         ---------------------------------------------------------------- 
        | 0x0e      | Vcc +12V SUS     | 11.95   | Healthy               |
        | 0x0f      | Vcc +5V SUS      | 4.98    | Healthy               |
        | 0x10      | Vcc +2.5V SUS    | 2.48    | Healthy               |
        | 0x11      | Vcc +1.8V SUS    | 1.80    | Healthy               |
        | 0x12      | Vcc +1.5V SUS    | 1.49    | Healthy               |
        | 0x13      | Vcc +1.25V SUS   | 1.25    | Healthy               |
        | 0x14      | Vcc +0.75V SUS   | 0.74    | Healthy               |
        | 0x04      | Temp Inlet       | 24.00   | Healthy               |
        | 0x05      | Temp Outlet      | 42.00   | Healthy               |
        | 0x07      | Temp BMC         | 45.00   | Healthy               |
        | 0x08      | Temp CPU 1       | 56.00   | Healthy               |
        | 0x09      | Temp CPU 2       | 47.00   | Healthy               |
Hotswap Status: Active
Product name: 4009
Part number: 1062-0224
Serial number: 9016240745
Manufacturing date: Wed Mar 14 17:04:00 2018
Type: Node
Model: MSP805x
HPM versions:
	BMC: 1.3.091805DF
	FPGA: 1.0.00000000
	BIOS: 1.1.0916DD5E
Management Network:
        Management MAC: 00:a0:a5:be:94:a8
        IP Source: dhcp
        IP: 10.24.58.142
        Subnet: 255.255.255.0
        Gateway: 10.24.58.3
        VLAN: FFD
Payload IPs :
	Network Interfaces:
		Id: 1, 
		Backplane: Base2, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:be:94:a2
		IP Source: static


		Id: 2, 
		Backplane: Fabric1p1, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:be:94:a3
		IP Source: static


		Id: 3, 
		Backplane: Fabric2p2, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:be:94:a4
		IP Source: static


	Network Interfaces:
		Id: 1, 
		Backplane: Base1, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:be:94:a5
		IP Source: static


		Id: 2, 
		Backplane: Fabric1p2, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:be:94:a6
		IP Source: static


		Id: 3, 
		Backplane: Fabric2p1, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:be:94:a7
		IP Source: static

================================

================================
SLOT #8
================================
Name: Node 8
Health: Healthy
Health Details: 
        | Sensor ID | Sensor Name      | Value   | Health                |
         ---------------------------------------------------------------- 
        | 0x0e      | Vcc +12V SUS     | 11.95   | Healthy               |
        | 0x0f      | Vcc +5V SUS      | 5.10    | Healthy               |
        | 0x10      | Vcc +2.5V SUS    | 2.49    | Healthy               |
        | 0x11      | Vcc +1.8V SUS    | 1.81    | Healthy               |
        | 0x12      | Vcc +1.5V SUS    | 1.50    | Healthy               |
        | 0x13      | Vcc +1.25V SUS   | 1.25    | Healthy               |
        | 0x14      | Vcc +0.75V SUS   | 0.75    | Healthy               |
        | 0x04      | Temp Inlet       | 24.00   | Healthy               |
        | 0x05      | Temp Outlet      | 43.00   | Healthy               |
        | 0x07      | Temp BMC         | 44.00   | Healthy               |
        | 0x08      | Temp CPU 1       | 59.00   | Healthy               |
        | 0x09      | Temp CPU 2       | 42.00   | Healthy               |
Hotswap Status: Active
Product name: 4009
Part number: 1062-0224
Serial number: 9016252643
Manufacturing date: Wed Mar 14 17:30:00 2018
Type: Node
Model: MSP805x
HPM versions:
	BMC: 1.3.091805DF
	FPGA: 1.0.00000000
	BIOS: 1.1.0916DD5E
Management Network:
        Management MAC: 00:a0:a5:c2:cb:f4
        IP Source: dhcp
        IP: 10.24.58.158
        Subnet: 255.255.255.0
        Gateway: 10.24.58.3
        VLAN: FFD
Payload IPs :
	Network Interfaces:
		Id: 1, 
		Backplane: Base2, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:c2:cb:ee
		IP Source: static


		Id: 2, 
		Backplane: Fabric1p1, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:c2:cb:ef
		IP Source: static


		Id: 3, 
		Backplane: Fabric2p2, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:c2:cb:f0
		IP Source: static


	Network Interfaces:
		Id: 1, 
		Backplane: Base1, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:c2:cb:f1
		IP Source: static


		Id: 2, 
		Backplane: Fabric1p2, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:c2:cb:f2
		IP Source: static


		Id: 3, 
		Backplane: Fabric2p1, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:c2:cb:f3
		IP Source: static

================================

================================
SLOT #9
================================
Name: Node 9
Health: Healthy
Health Details: 
        | Sensor ID | Sensor Name      | Value   | Health                |
         ---------------------------------------------------------------- 
        | 0x0e      | Vcc +12V SUS     | 12.01   | Healthy               |
        | 0x0f      | Vcc +5V SUS      | 4.96    | Healthy               |
        | 0x10      | Vcc +2.5V SUS    | 2.49    | Healthy               |
        | 0x11      | Vcc +1.8V SUS    | 1.80    | Healthy               |
        | 0x12      | Vcc +1.5V SUS    | 1.49    | Healthy               |
        | 0x13      | Vcc +1.25V SUS   | 1.25    | Healthy               |
        | 0x14      | Vcc +0.75V SUS   | 0.74    | Healthy               |
        | 0x04      | Temp Inlet       | 26.00   | Healthy               |
        | 0x05      | Temp Outlet      | 43.00   | Healthy               |
        | 0x07      | Temp BMC         | 44.00   | Healthy               |
        | 0x08      | Temp CPU 1       | 60.00   | Healthy               |
        | 0x09      | Temp CPU 2       | 45.00   | Healthy               |
Hotswap Status: Active
Product name: 4009
Part number: 1062-0224
Serial number: 9016252690
Manufacturing date: Wed Mar 14 17:30:00 2018
Type: Node
Model: MSP805x
HPM versions:
	BMC: 1.3.091805DF
	FPGA: 1.0.00000000
	BIOS: 1.1.0916DD5E
Management Network:
        Management MAC: 00:a0:a5:c2:ce:64
        IP Source: dhcp
        IP: 10.24.58.188
        Subnet: 255.255.255.0
        Gateway: 10.24.58.3
        VLAN: FFD
Payload IPs :
	Network Interfaces:
		Id: 1, 
		Backplane: Base2, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:c2:ce:5e
		IP Source: static


		Id: 2, 
		Backplane: Fabric1p1, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:c2:ce:5f
		IP Source: static


		Id: 3, 
		Backplane: Fabric2p2, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:c2:ce:60
		IP Source: static


	Network Interfaces:
		Id: 1, 
		Backplane: Base1, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:c2:ce:61
		IP Source: static


		Id: 2, 
		Backplane: Fabric1p2, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:c2:ce:62
		IP Source: static


		Id: 3, 
		Backplane: Fabric2p1, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:c2:ce:63
		IP Source: static

================================

*******************************
Original JSON string
*******************************
{ "name": "Platform #1", "number": "1", "chassis": "ms2900", "health": "Green", "fans":[ {"number": "1", "name": "Fan 1", "type": "fan", "health": "Green", "rpm": "8393","alarm": {"alarmlevel": "None"}, "LedIdentify": {"status": "off"}, "hotswapStatus":{"state": "M4", "text": "Active"}}, {"number": "2", "name": "Fan 2", "type": "fan", "health": "Green", "rpm": "8470","alarm": {"alarmlevel": "None"}, "LedIdentify": {"status": "off"}, "hotswapStatus":{"state": "M4", "text": "Active"}}, {"number": "3", "name": "Fan 3", "type": "fan", "health": "Green", "rpm": "8470","alarm": {"alarmlevel": "None"}, "LedIdentify": {"status": "off"}, "hotswapStatus":{"state": "M4", "text": "Active"}}, {"number": "4", "name": "Fan 4", "type": "fan", "health": "Green", "rpm": "8393","alarm": {"alarmlevel": "None"}, "LedIdentify": {"status": "off"}, "hotswapStatus":{"state": "M4", "text": "Active"}}, {"number": "5", "name": "Fan 5", "type": "fan", "health": "Green", "rpm": "8316","alarm": {"alarmlevel": "None"}, "LedIdentify": {"status": "off"}, "hotswapStatus":{"state": "M4", "text": "Active"}} ], "type": "platform", "components": [{"number": "10", "name": "HubNode 1", "health": "Green", "fruInfo": {"mfgDate": "Wed Mar 14 13:08:00 2018", "boardMfg": "Kontron", "boardProductName": "MSH8900", "boardProductPart": "T4301X_2-X", "boardSerialNumber": "9016242282"},"hotswapStatus":{"state": "M4", "text": "Active"},"type":"hubnode", "HubNodeFeatures":{"SwitchSpeedSupport": "1", "PortModeSupport": "0"}, "versions" : [{ "name" : "BMC", "major" : "3", "minor" : "18", "revision" : "093413FB"},{ "name" : "FPGA", "major" : "2", "minor" : "04", "revision" : "00000000"}],"model": "MSH8900", "isUpdating" : "0", "managementIP": "10.24.58.112", "managementMAC": "00:a0:a5:c1:27:99", "alarm": {"alarmlevel": "None", "sensors":[]}, "LedIdentify": {"status": "off"}, "components": [{ "description": "Switch 1", "number": "1", "hotswapStatus":{"state": "M4", "text": "Active"}, "networkInterfaces": [{ "id": "1", "backplane": "Management", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:c1:27:7a"}]}], "status": "Active"}, {"number": "11", "name": "HubNode 2", "health": "Green", "fruInfo": {"mfgDate": "Wed Mar 14 13:08:00 2018", "boardMfg": "Kontron", "boardProductName": "MSH8900", "boardProductPart": "T4301X_2-X", "boardSerialNumber": "9016242314"},"hotswapStatus":{"state": "M4", "text": "Active"},"type":"hubnode", "HubNodeFeatures":{"SwitchSpeedSupport": "1", "PortModeSupport": "0"}, "versions" : [{ "name" : "BMC", "major" : "3", "minor" : "18", "revision" : "093413FB"},{ "name" : "FPGA", "major" : "2", "minor" : "04", "revision" : "00000000"}],"model": "MSH8900", "isUpdating" : "0", "managementIP": "10.24.58.123", "managementMAC": "00:a0:a5:c1:31:3d", "alarm": {"alarmlevel": "None", "sensors":[]}, "LedIdentify": {"status": "off"}, "components": [{ "description": "Switch 2", "number": "1", "hotswapStatus":{"state": "M4", "text": "Active"}, "networkInterfaces": [{ "id": "1", "backplane": "Management", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:c1:31:1e"}]}], "status": "Standby"}, {"number": "1", "name": "Node 1", "health": "Green", "fruInfo": {"mfgDate": "Wed Mar 14 12:41:00 2018", "boardMfg": "Kontron", "boardProductName": "4009", "boardProductPart": "1062-0224", "boardSerialNumber": "9016252652"},"hotswapStatus":{"state": "M4", "text": "Active"},"type":"node", "versions" : [{ "name" : "BMC", "major" : "1", "minor" : "03", "revision" : "091805DF"},{ "name" : "FPGA", "major" : "1", "minor" : "00", "revision" : "00000000"},{ "name" : "BIOS", "major" : "1", "minor" : "01", "revision" : "0916DD5E"}],"model": "MSP805x", "isUpdating" : "0", "managementIP": "10.24.58.146", "managementMAC": "00:a0:a5:c2:ca:e2", "alarm": {"alarmlevel": "None", "sensors":[]}, "LedIdentify": {"status": "off"}, "components": [{ "description": "Payload1       ", "number": "1", "hotswapStatus":{"state": "M4", "text": "Active"}, "networkInterfaces": [{ "id": "1", "backplane": "Base2", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:c2:ca:dc"}, { "id": "2", "backplane": "Fabric1p1", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:c2:ca:dd"}, { "id": "3", "backplane": "Fabric2p2", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:c2:ca:de"}]}, { "description": "Payload2       ", "number": "2", "hotswapStatus":{"state": "M4", "text": "Active"}, "networkInterfaces": [{ "id": "1", "backplane": "Base1", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:c2:ca:df"}, { "id": "2", "backplane": "Fabric1p2", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:c2:ca:e0"}, { "id": "3", "backplane": "Fabric2p1", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:c2:ca:e1"}]}] }, {"number": "2", "name": "Node 2", "health": "Green", "fruInfo": {"mfgDate": "Wed Mar 14 12:42:00 2018", "boardMfg": "Kontron", "boardProductName": "4009", "boardProductPart": "1062-0224", "boardSerialNumber": "9016240704"},"hotswapStatus":{"state": "M4", "text": "Active"},"type":"node", "versions" : [{ "name" : "BMC", "major" : "1", "minor" : "03", "revision" : "091805DF"},{ "name" : "FPGA", "major" : "1", "minor" : "00", "revision" : "00000000"},{ "name" : "BIOS", "major" : "1", "minor" : "01", "revision" : "0916DD5E"}],"model": "MSP805x", "isUpdating" : "0", "managementIP": "10.24.58.132", "managementMAC": "00:a0:a5:bf:24:30", "alarm": {"alarmlevel": "None", "sensors":[]}, "LedIdentify": {"status": "off"}, "components": [{ "description": "Payload1       ", "number": "1", "hotswapStatus":{"state": "M4", "text": "Active"}, "networkInterfaces": [{ "id": "1", "backplane": "Base2", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:bf:24:2a"}, { "id": "2", "backplane": "Fabric1p1", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:bf:24:2b"}, { "id": "3", "backplane": "Fabric2p2", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:bf:24:2c"}]}, { "description": "Payload2       ", "number": "2", "hotswapStatus":{"state": "M4", "text": "Active"}, "networkInterfaces": [{ "id": "1", "backplane": "Base1", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:bf:24:2d"}, { "id": "2", "backplane": "Fabric1p2", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:bf:24:2e"}, { "id": "3", "backplane": "Fabric2p1", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:bf:24:2f"}]}] }, {"number": "3", "name": "Node 3", "health": "Green", "fruInfo": {"mfgDate": "Wed Mar 14 14:20:00 2018", "boardMfg": "Kontron", "boardProductName": "4009", "boardProductPart": "1062-0224", "boardSerialNumber": "9016240691"},"hotswapStatus":{"state": "M4", "text": "Active"},"type":"node", "versions" : [{ "name" : "BMC", "major" : "1", "minor" : "03", "revision" : "091805DF"},{ "name" : "FPGA", "major" : "1", "minor" : "00", "revision" : "00000000"},{ "name" : "BIOS", "major" : "1", "minor" : "01", "revision" : "0916DD5E"}],"model": "MSP805x", "isUpdating" : "0", "managementIP": "10.24.58.166", "managementMAC": "00:a0:a5:bf:23:74", "alarm": {"alarmlevel": "None", "sensors":[]}, "LedIdentify": {"status": "off"}, "components": [{ "description": "Payload1       ", "number": "1", "hotswapStatus":{"state": "M4", "text": "Active"}, "networkInterfaces": [{ "id": "1", "backplane": "Base2", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:bf:23:6e"}, { "id": "2", "backplane": "Fabric1p1", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:bf:23:6f"}, { "id": "3", "backplane": "Fabric2p2", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:bf:23:70"}]}, { "description": "Payload2       ", "number": "2", "hotswapStatus":{"state": "M4", "text": "Active"}, "networkInterfaces": [{ "id": "1", "backplane": "Base1", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:bf:23:71"}, { "id": "2", "backplane": "Fabric1p2", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:bf:23:72"}, { "id": "3", "backplane": "Fabric2p1", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:bf:23:73"}]}] }, {"number": "4", "name": "Node 4", "health": "Green", "fruInfo": {"mfgDate": "Wed Mar 14 14:17:00 2018", "boardMfg": "Kontron", "boardProductName": "4009", "boardProductPart": "1062-0224", "boardSerialNumber": "9016252749"},"hotswapStatus":{"state": "M4", "text": "Active"},"type":"node", "versions" : [{ "name" : "BMC", "major" : "1", "minor" : "03", "revision" : "091805DF"},{ "name" : "FPGA", "major" : "1", "minor" : "00", "revision" : "00000000"},{ "name" : "BIOS", "major" : "1", "minor" : "01", "revision" : "0916DD5E"}],"model": "MSP805x", "isUpdating" : "0", "managementIP": "10.24.58.192", "managementMAC": "00:a0:a5:c2:ce:2c", "alarm": {"alarmlevel": "None", "sensors":[]}, "LedIdentify": {"status": "off"}, "components": [{ "description": "Payload1       ", "number": "1", "hotswapStatus":{"state": "M4", "text": "Active"}, "networkInterfaces": [{ "id": "1", "backplane": "Base2", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:c2:ce:26"}, { "id": "2", "backplane": "Fabric1p1", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:c2:ce:27"}, { "id": "3", "backplane": "Fabric2p2", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:c2:ce:28"}]}, { "description": "Payload2       ", "number": "2", "hotswapStatus":{"state": "M4", "text": "Active"}, "networkInterfaces": [{ "id": "1", "backplane": "Base1", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:c2:ce:29"}, { "id": "2", "backplane": "Fabric1p2", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:c2:ce:2a"}, { "id": "3", "backplane": "Fabric2p1", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:c2:ce:2b"}]}] }, {"number": "5", "name": "Node 5", "health": "Green", "fruInfo": {"mfgDate": "Wed Mar 14 17:04:00 2018", "boardMfg": "Kontron", "boardProductName": "4009", "boardProductPart": "1062-0224", "boardSerialNumber": "9016252735"},"hotswapStatus":{"state": "M4", "text": "Active"},"type":"node", "versions" : [{ "name" : "BMC", "major" : "1", "minor" : "03", "revision" : "091805DF"},{ "name" : "FPGA", "major" : "1", "minor" : "00", "revision" : "00000000"},{ "name" : "BIOS", "major" : "1", "minor" : "01", "revision" : "0916DD5E"}],"model": "MSP805x", "isUpdating" : "0", "managementIP": "10.24.58.140", "managementMAC": "00:a0:a5:c2:ca:aa", "alarm": {"alarmlevel": "None", "sensors":[]}, "LedIdentify": {"status": "off"}, "components": [{ "description": "Payload1       ", "number": "1", "hotswapStatus":{"state": "M4", "text": "Active"}, "networkInterfaces": [{ "id": "1", "backplane": "Base2", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:c2:ca:a4"}, { "id": "2", "backplane": "Fabric1p1", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:c2:ca:a5"}, { "id": "3", "backplane": "Fabric2p2", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:c2:ca:a6"}]}, { "description": "Payload2       ", "number": "2", "hotswapStatus":{"state": "M4", "text": "Active"}, "networkInterfaces": [{ "id": "1", "backplane": "Base1", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:c2:ca:a7"}, { "id": "2", "backplane": "Fabric1p2", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:c2:ca:a8"}, { "id": "3", "backplane": "Fabric2p1", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:c2:ca:a9"}]}] }, {"number": "6", "name": "Node 6", "health": "Green", "fruInfo": {"mfgDate": "Wed Mar 14 17:04:00 2018", "boardMfg": "Kontron", "boardProductName": "4009", "boardProductPart": "1062-0224", "boardSerialNumber": "9016240767"},"hotswapStatus":{"state": "M4", "text": "Active"},"type":"node", "versions" : [{ "name" : "BMC", "major" : "1", "minor" : "03", "revision" : "091805DF"},{ "name" : "FPGA", "major" : "1", "minor" : "00", "revision" : "00000000"},{ "name" : "BIOS", "major" : "1", "minor" : "01", "revision" : "0916DD5E"}],"model": "MSP805x", "isUpdating" : "0", "managementIP": "10.24.58.160", "managementMAC": "00:a0:a5:be:93:b4", "alarm": {"alarmlevel": "None", "sensors":[]}, "LedIdentify": {"status": "off"}, "components": [{ "description": "Payload1       ", "number": "1", "hotswapStatus":{"state": "M4", "text": "Active"}, "networkInterfaces": [{ "id": "1", "backplane": "Base2", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:be:93:ae"}, { "id": "2", "backplane": "Fabric1p1", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:be:93:af"}, { "id": "3", "backplane": "Fabric2p2", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:be:93:b0"}]}, { "description": "Payload2       ", "number": "2", "hotswapStatus":{"state": "M4", "text": "Active"}, "networkInterfaces": [{ "id": "1", "backplane": "Base1", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:be:93:b1"}, { "id": "2", "backplane": "Fabric1p2", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:be:93:b2"}, { "id": "3", "backplane": "Fabric2p1", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:be:93:b3"}]}] }, {"number": "7", "name": "Node 7", "health": "Green", "fruInfo": {"mfgDate": "Wed Mar 14 17:04:00 2018", "boardMfg": "Kontron", "boardProductName": "4009", "boardProductPart": "1062-0224", "boardSerialNumber": "9016240745"},"hotswapStatus":{"state": "M4", "text": "Active"},"type":"node", "versions" : [{ "name" : "BMC", "major" : "1", "minor" : "03", "revision" : "091805DF"},{ "name" : "FPGA", "major" : "1", "minor" : "00", "revision" : "00000000"},{ "name" : "BIOS", "major" : "1", "minor" : "01", "revision" : "0916DD5E"}],"model": "MSP805x", "isUpdating" : "0", "managementIP": "10.24.58.142", "managementMAC": "00:a0:a5:be:94:a8", "alarm": {"alarmlevel": "None", "sensors":[]}, "LedIdentify": {"status": "off"}, "components": [{ "description": "Payload1       ", "number": "1", "hotswapStatus":{"state": "M4", "text": "Active"}, "networkInterfaces": [{ "id": "1", "backplane": "Base2", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:be:94:a2"}, { "id": "2", "backplane": "Fabric1p1", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:be:94:a3"}, { "id": "3", "backplane": "Fabric2p2", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:be:94:a4"}]}, { "description": "Payload2       ", "number": "2", "hotswapStatus":{"state": "M4", "text": "Active"}, "networkInterfaces": [{ "id": "1", "backplane": "Base1", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:be:94:a5"}, { "id": "2", "backplane": "Fabric1p2", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:be:94:a6"}, { "id": "3", "backplane": "Fabric2p1", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:be:94:a7"}]}] }, {"number": "8", "name": "Node 8", "health": "Green", "fruInfo": {"mfgDate": "Wed Mar 14 17:30:00 2018", "boardMfg": "Kontron", "boardProductName": "4009", "boardProductPart": "1062-0224", "boardSerialNumber": "9016252643"},"hotswapStatus":{"state": "M4", "text": "Active"},"type":"node", "versions" : [{ "name" : "BMC", "major" : "1", "minor" : "03", "revision" : "091805DF"},{ "name" : "FPGA", "major" : "1", "minor" : "00", "revision" : "00000000"},{ "name" : "BIOS", "major" : "1", "minor" : "01", "revision" : "0916DD5E"}],"model": "MSP805x", "isUpdating" : "0", "managementIP": "10.24.58.158", "managementMAC": "00:a0:a5:c2:cb:f4", "alarm": {"alarmlevel": "None", "sensors":[]}, "LedIdentify": {"status": "off"}, "components": [{ "description": "Payload1       ", "number": "1", "hotswapStatus":{"state": "M4", "text": "Active"}, "networkInterfaces": [{ "id": "1", "backplane": "Base2", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:c2:cb:ee"}, { "id": "2", "backplane": "Fabric1p1", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:c2:cb:ef"}, { "id": "3", "backplane": "Fabric2p2", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:c2:cb:f0"}]}, { "description": "Payload2       ", "number": "2", "hotswapStatus":{"state": "M4", "text": "Active"}, "networkInterfaces": [{ "id": "1", "backplane": "Base1", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:c2:cb:f1"}, { "id": "2", "backplane": "Fabric1p2", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:c2:cb:f2"}, { "id": "3", "backplane": "Fabric2p1", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:c2:cb:f3"}]}] }, {"number": "9", "name": "Node 9", "health": "Green", "fruInfo": {"mfgDate": "Wed Mar 14 17:30:00 2018", "boardMfg": "Kontron", "boardProductName": "4009", "boardProductPart": "1062-0224", "boardSerialNumber": "9016252690"},"hotswapStatus":{"state": "M4", "text": "Active"},"type":"node", "versions" : [{ "name" : "BMC", "major" : "1", "minor" : "03", "revision" : "091805DF"},{ "name" : "FPGA", "major" : "1", "minor" : "00", "revision" : "00000000"},{ "name" : "BIOS", "major" : "1", "minor" : "01", "revision" : "0916DD5E"}],"model": "MSP805x", "isUpdating" : "0", "managementIP": "10.24.58.188", "managementMAC": "00:a0:a5:c2:ce:64", "alarm": {"alarmlevel": "None", "sensors":[]}, "LedIdentify": {"status": "off"}, "components": [{ "description": "Payload1       ", "number": "1", "hotswapStatus":{"state": "M4", "text": "Active"}, "networkInterfaces": [{ "id": "1", "backplane": "Base2", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:c2:ce:5e"}, { "id": "2", "backplane": "Fabric1p1", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:c2:ce:5f"}, { "id": "3", "backplane": "Fabric2p2", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:c2:ce:60"}]}, { "description": "Payload2       ", "number": "2", "hotswapStatus":{"state": "M4", "text": "Active"}, "networkInterfaces": [{ "id": "1", "backplane": "Base1", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:c2:ce:61"}, { "id": "2", "backplane": "Fabric1p2", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:c2:ce:62"}, { "id": "3", "backplane": "Fabric2p1", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:c2:ce:63"}]}] }, { "name": "PSU", "components": [{"id": "PSU1", "number": "1", "name": "Power Supply 1", "health": "Green", "type": "psu", "hotswapStatus":{"state": "M4", "text": "Active"},"alarm": {"alarmlevel": "None"}, "tempInlet": "20.00", "tempOutlet": "27.00", "vIn": "204.00", "powerOut": "400", "powerScale": "1400","peakConsumption": "480", "averageConsumption": "379"},{"id": "PSU2", "number": "2", "name": "Power Supply 2", "health": "Green", "type": "psu", "hotswapStatus":{"state": "M4", "text": "Active"},"alarm": {"alarmlevel": "None"}, "tempInlet": "19.00", "tempOutlet": "26.00", "vIn": "204.00", "powerOut": "376", "powerScale": "1400","peakConsumption": "472", "averageConsumption": "381"}]}], "switchOID": {"oid": "1.3.6.1.4.1.6603"}, "alarm": {"alarmlevel": "None",  "components" : [ {"nodes" : [] } , {"psu" : [] }, {"fans" : [] }], "text": ""}, "LedIdentify": {"status": "off"}}