System informations
*******************************
Name: SYMKLOUD
chassis: ms2900
Health: Healthy
*******************************
Fans: 
*******************************
Fan 1: 
	Present :true
	Status :Healthy
	8239 RPM
Fan 2: 
	Present :true
	Status :Healthy
	8239 RPM
Fan 3: 
	Present :true
	Status :Healthy
	8239 RPM
Fan 4: 
	Present :true
	Status :Healthy
	8316 RPM
Fan 5: 
	Present :true
	Status :Healthy
	8239 RPM


*******************************
PSU: 
*******************************
Name: PSU 1
Health: Healthy
Health Details: No details available
Hotswap Status: Active
FRU: Informations are invalid

Name: PSU 2
Health: Healthy
Health Details: No details available
Hotswap Status: Active
FRU: Informations are invalid



*******************************
HubNodes
*******************************

================================
Name: HubNode 1
Health: Healthy
Health Details: 
        | Sensor ID | Sensor Name      | Value   | Health                |
         ---------------------------------------------------------------- 
        | 0x0b      | Temp On-Board    | 30.00   | Healthy               |
        | 0x0c      | Temp Eth Switch  | 30.00   | Healthy               |
        | 0x0d      | Temp Quad Phy    | 36.00   | Healthy               |
        | 0x0e      | Temp Inlet       | 23.00   | Healthy               |
        | 0x0f      | Temp Phy 10G     | 54.00   | Healthy               |
        | 0x10      | Vcc +12V In      | 12.18   | Healthy               |
        | 0x11      | Vcc +5V SUS      | 5.08    | Healthy               |
        | 0x12      | Vcc +3.3V SUS    | 3.31    | Healthy               |
        | 0x13      | Vcc +1.8V SUS    | 1.79    | Healthy               |
        | 0x14      | Vcc +1.5V SUS    | 1.51    | Healthy               |
        | 0x15      | Vcc +1.25V SUS   | 1.24    | Healthy               |
        | 0x16      | Vcc +1.2V SUS    | 1.21    | Healthy               |
        | 0x17      | Vcc +0.75V SUS   | 0.75    | Healthy               |
        | 0x18      | Vcc +3.3V        | 3.29    | Healthy               |
        | 0x19      | Vcc +2.5V        | 2.47    | Healthy               |
        | 0x1a      | Vcc +1.8V        | 1.78    | Healthy               |
        | 0x1b      | Vcc +1.2V        | 1.21    | Healthy               |
        | 0x1c      | Vcc +1.0V        | 1.01    | Healthy               |
        | 0x1d      | Vbat +3V         | 3.06    | Healthy               |
        | 0x3f      | Power Good Latch | 0x8001  | Healthy               |
        | 0x40      | FPGA RW Status   | 0x8002  | Healthy               |
        | 0x41      | FPGA Heartbeat   | 0x8002  | Healthy               |
        | 0x48      | ShMC Redun State | 0x8002  | Healthy               |
Hotswap Status: Active
Product name: MSH8900
Part number: T4301X_2-X
Serial number: 9017009237
Manufacturing date: Wed Oct 24 14:57:00 2018
Type: HubNode
Status: Active
Model: MSH8900
HPM versions:
	BMC: 3.16.09289D46
	FPGA: 2.6.00000000
Management Network:
        Management MAC: 00:a0:a5:cf:9f:3b
        IP Source: dhcp
        IP: 10.24.97.89
        Subnet: 255.255.255.0
        Gateway: 10.24.97.3
        VLAN: FFD
Payload IPs :
	Network Interfaces:
		Id: 1, 
		Backplane: Unknown, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:cf:9f:3b
		IP Source: static

================================

================================
Name: HubNode 2
Health: Healthy
Health Details: 
        | Sensor ID | Sensor Name      | Value   | Health                |
         ---------------------------------------------------------------- 
        | 0x0b      | Temp On-Board    | 30.00   | Healthy               |
        | 0x0c      | Temp Eth Switch  | 30.00   | Healthy               |
        | 0x0d      | Temp Quad Phy    | 36.00   | Healthy               |
        | 0x0e      | Temp Inlet       | 23.00   | Healthy               |
        | 0x0f      | Temp Phy 10G     | 51.00   | Healthy               |
        | 0x10      | Vcc +12V In      | 12.06   | Healthy               |
        | 0x11      | Vcc +5V SUS      | 5.05    | Healthy               |
        | 0x12      | Vcc +3.3V SUS    | 3.31    | Healthy               |
        | 0x13      | Vcc +1.8V SUS    | 1.79    | Healthy               |
        | 0x14      | Vcc +1.5V SUS    | 1.51    | Healthy               |
        | 0x15      | Vcc +1.25V SUS   | 1.24    | Healthy               |
        | 0x16      | Vcc +1.2V SUS    | 1.19    | Healthy               |
        | 0x17      | Vcc +0.75V SUS   | 0.75    | Healthy               |
        | 0x18      | Vcc +3.3V        | 3.31    | Healthy               |
        | 0x19      | Vcc +2.5V        | 2.47    | Healthy               |
        | 0x1a      | Vcc +1.8V        | 1.79    | Healthy               |
        | 0x1b      | Vcc +1.2V        | 1.21    | Healthy               |
        | 0x1c      | Vcc +1.0V        | 1.01    | Healthy               |
        | 0x1d      | Vbat +3V         | 3.06    | Healthy               |
        | 0x3f      | Power Good Latch | 0x8001  | Healthy               |
        | 0x40      | FPGA RW Status   | 0x8002  | Healthy               |
        | 0x41      | FPGA Heartbeat   | 0x8002  | Healthy               |
        | 0x48      | ShMC Redun State | 0x8008  | Healthy               |
Hotswap Status: Active
Product name: MSH8900
Part number: T4301X_2-X
Serial number: 9017009261
Manufacturing date: Wed Oct 24 15:05:00 2018
Type: HubNode
Status: Standby
Model: MSH8900
HPM versions:
	BMC: 3.16.09289D46
	FPGA: 2.6.00000000
Management Network:
        Management MAC: 00:a0:a5:cf:a0:5b
        IP Source: dhcp
        IP: 10.24.97.79
        Subnet: 255.255.255.0
        Gateway: 10.24.97.3
        VLAN: FFD
Payload IPs :
	Network Interfaces:
		Id: 1, 
		Backplane: Unknown, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:cf:a0:5b
		IP Source: static

================================

*******************************
Nodes
*******************************

================================
SLOT #1
================================
Name: Node 1
Health: Healthy
Health Details: 
        | Sensor ID | Sensor Name      | Value   | Health                |
         ---------------------------------------------------------------- 
        | 0x0e      | Vcc +12V SUS     | 12.06   | Healthy               |
        | 0x0f      | Vcc +5V SUS      | 4.98    | Healthy               |
        | 0x10      | Vcc +2.5V SUS    | 2.48    | Healthy               |
        | 0x11      | Vcc +1.8V SUS    | 1.81    | Healthy               |
        | 0x12      | Vcc +1.5V SUS    | 1.49    | Healthy               |
        | 0x13      | Vcc +1.25V SUS   | 1.24    | Healthy               |
        | 0x14      | Vcc +0.75V SUS   | 0.75    | Healthy               |
        | 0x04      | Temp Inlet       | 30.00   | Healthy               |
        | 0x05      | Temp Outlet      | 47.00   | Healthy               |
        | 0x07      | Temp BMC         | 49.00   | Healthy               |
        | 0x08      | Temp CPU 1       | 62.00   | Healthy               |
        | 0x09      | Temp CPU 2       | 48.00   | Healthy               |
Hotswap Status: Active
Product name: 4009
Part number: 1062-0224
Serial number: 9017009440
Manufacturing date: Mon Oct 22 16:31:00 2018
Type: Node
Model: MSP805x
HPM versions:
	BMC: 1.3.091805DF
	FPGA: 1.0.00000000
	BIOS: 1.1.0916DD5E
Management Network:
        Management MAC: 00:a0:a5:cf:13:30
        IP Source: dhcp
        IP: 10.24.97.92
        Subnet: 255.255.255.0
        Gateway: 10.24.97.3
        VLAN: FFD
Payload IPs :
	Network Interfaces:
		Id: 1, 
		Backplane: Base2, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:cf:13:2a
		IP Source: static


		Id: 2, 
		Backplane: Fabric1p1, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:cf:13:2b
		IP Source: static


		Id: 3, 
		Backplane: Fabric2p2, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:cf:13:2c
		IP Source: static


	Network Interfaces:
		Id: 1, 
		Backplane: Base1, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:cf:13:2d
		IP Source: static


		Id: 2, 
		Backplane: Fabric1p2, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:cf:13:2e
		IP Source: static


		Id: 3, 
		Backplane: Fabric2p1, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:cf:13:2f
		IP Source: static

================================

================================
SLOT #2
================================
Name: Node 2
Health: Healthy
Health Details: 
        | Sensor ID | Sensor Name      | Value   | Health                |
         ---------------------------------------------------------------- 
        | 0x0e      | Vcc +12V SUS     | 12.01   | Healthy               |
        | 0x0f      | Vcc +5V SUS      | 5.03    | Healthy               |
        | 0x10      | Vcc +2.5V SUS    | 2.48    | Healthy               |
        | 0x11      | Vcc +1.8V SUS    | 1.80    | Healthy               |
        | 0x12      | Vcc +1.5V SUS    | 1.49    | Healthy               |
        | 0x13      | Vcc +1.25V SUS   | 1.24    | Healthy               |
        | 0x14      | Vcc +0.75V SUS   | 0.74    | Healthy               |
        | 0x04      | Temp Inlet       | 28.00   | Healthy               |
        | 0x05      | Temp Outlet      | 47.00   | Healthy               |
        | 0x07      | Temp BMC         | 46.00   | Healthy               |
        | 0x08      | Temp CPU 1       | 59.00   | Healthy               |
        | 0x09      | Temp CPU 2       | 48.00   | Healthy               |
Hotswap Status: Active
Product name: 4009
Part number: 1062-0224
Serial number: 9017009444
Manufacturing date: Mon Oct 22 16:31:00 2018
Type: Node
Model: MSP805x
HPM versions:
	BMC: 1.3.091805DF
	FPGA: 1.0.00000000
	BIOS: 1.1.0916DD5E
Management Network:
        Management MAC: 00:a0:a5:cf:16:e4
        IP Source: dhcp
        IP: 10.24.97.50
        Subnet: 255.255.255.0
        Gateway: 10.24.97.3
        VLAN: FFD
Payload IPs :
	Network Interfaces:
		Id: 1, 
		Backplane: Base2, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:cf:16:de
		IP Source: static


		Id: 2, 
		Backplane: Fabric1p1, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:cf:16:df
		IP Source: static


		Id: 3, 
		Backplane: Fabric2p2, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:cf:16:e0
		IP Source: static


	Network Interfaces:
		Id: 1, 
		Backplane: Base1, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:cf:16:e1
		IP Source: static


		Id: 2, 
		Backplane: Fabric1p2, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:cf:16:e2
		IP Source: static


		Id: 3, 
		Backplane: Fabric2p1, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:cf:16:e3
		IP Source: static

================================

================================
SLOT #3
================================
Name: Node 3
Health: Healthy
Health Details: 
        | Sensor ID | Sensor Name      | Value   | Health                |
         ---------------------------------------------------------------- 
        | 0x0e      | Vcc +12V SUS     | 12.06   | Healthy               |
        | 0x0f      | Vcc +5V SUS      | 5.03    | Healthy               |
        | 0x10      | Vcc +2.5V SUS    | 2.48    | Healthy               |
        | 0x11      | Vcc +1.8V SUS    | 1.81    | Healthy               |
        | 0x12      | Vcc +1.5V SUS    | 1.49    | Healthy               |
        | 0x13      | Vcc +1.25V SUS   | 1.25    | Healthy               |
        | 0x14      | Vcc +0.75V SUS   | 0.74    | Healthy               |
        | 0x04      | Temp Inlet       | 26.00   | Healthy               |
        | 0x05      | Temp Outlet      | 46.00   | Healthy               |
        | 0x07      | Temp BMC         | 45.00   | Healthy               |
        | 0x08      | Temp CPU 1       | 59.00   | Healthy               |
        | 0x09      | Temp CPU 2       | 46.00   | Healthy               |
Hotswap Status: Active
Product name: 4009
Part number: 1062-0224
Serial number: 9017009451
Manufacturing date: Mon Oct 22 16:34:00 2018
Type: Node
Model: MSP805x
HPM versions:
	BMC: 1.3.091805DF
	FPGA: 1.0.00000000
	BIOS: 1.1.0916DD5E
Management Network:
        Management MAC: 00:a0:a5:cf:16:54
        IP Source: dhcp
        IP: 10.24.97.144
        Subnet: 255.255.255.0
        Gateway: 10.24.97.3
        VLAN: FFD
Payload IPs :
	Network Interfaces:
		Id: 1, 
		Backplane: Base2, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:cf:16:4e
		IP Source: static


		Id: 2, 
		Backplane: Fabric1p1, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:cf:16:4f
		IP Source: static


		Id: 3, 
		Backplane: Fabric2p2, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:cf:16:50
		IP Source: static


	Network Interfaces:
		Id: 1, 
		Backplane: Base1, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:cf:16:51
		IP Source: static


		Id: 2, 
		Backplane: Fabric1p2, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:cf:16:52
		IP Source: static


		Id: 3, 
		Backplane: Fabric2p1, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:cf:16:53
		IP Source: static

================================

================================
SLOT #4
================================
Name: Node 4
Health: Healthy
Health Details: 
        | Sensor ID | Sensor Name      | Value   | Health                |
         ---------------------------------------------------------------- 
        | 0x0e      | Vcc +12V SUS     | 12.01   | Healthy               |
        | 0x0f      | Vcc +5V SUS      | 5.03    | Healthy               |
        | 0x10      | Vcc +2.5V SUS    | 2.48    | Healthy               |
        | 0x11      | Vcc +1.8V SUS    | 1.80    | Healthy               |
        | 0x12      | Vcc +1.5V SUS    | 1.49    | Healthy               |
        | 0x13      | Vcc +1.25V SUS   | 1.25    | Healthy               |
        | 0x14      | Vcc +0.75V SUS   | 0.74    | Healthy               |
        | 0x04      | Temp Inlet       | 27.00   | Healthy               |
        | 0x05      | Temp Outlet      | 46.00   | Healthy               |
        | 0x07      | Temp BMC         | 49.00   | Healthy               |
        | 0x08      | Temp CPU 1       | 60.00   | Healthy               |
        | 0x09      | Temp CPU 2       | 48.00   | Healthy               |
Hotswap Status: Active
Product name: 4009
Part number: 1062-0224
Serial number: 9017009406
Manufacturing date: Mon Oct 22 17:29:00 2018
Type: Node
Model: MSP805x
HPM versions:
	BMC: 1.3.091805DF
	FPGA: 1.0.00000000
	BIOS: 1.1.0916DD5E
Management Network:
        Management MAC: 00:a0:a5:cf:15:f8
        IP Source: dhcp
        IP: 10.24.97.167
        Subnet: 255.255.255.0
        Gateway: 10.24.97.3
        VLAN: FFD
Payload IPs :
	Network Interfaces:
		Id: 1, 
		Backplane: Base2, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:cf:15:f2
		IP Source: static


		Id: 2, 
		Backplane: Fabric1p1, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:cf:15:f3
		IP Source: static


		Id: 3, 
		Backplane: Fabric2p2, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:cf:15:f4
		IP Source: static


	Network Interfaces:
		Id: 1, 
		Backplane: Base1, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:cf:15:f5
		IP Source: static


		Id: 2, 
		Backplane: Fabric1p2, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:cf:15:f6
		IP Source: static


		Id: 3, 
		Backplane: Fabric2p1, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:cf:15:f7
		IP Source: static

================================

================================
SLOT #5
================================
Name: Node 5
Health: Healthy
Health Details: 
        | Sensor ID | Sensor Name      | Value   | Health                |
         ---------------------------------------------------------------- 
        | 0x0e      | Vcc +12V SUS     | 12.06   | Healthy               |
        | 0x0f      | Vcc +5V SUS      | 5.03    | Healthy               |
        | 0x10      | Vcc +2.5V SUS    | 2.48    | Healthy               |
        | 0x11      | Vcc +1.8V SUS    | 1.80    | Healthy               |
        | 0x12      | Vcc +1.5V SUS    | 1.49    | Healthy               |
        | 0x13      | Vcc +1.25V SUS   | 1.25    | Healthy               |
        | 0x14      | Vcc +0.75V SUS   | 0.75    | Healthy               |
        | 0x04      | Temp Inlet       | 27.00   | Healthy               |
        | 0x05      | Temp Outlet      | 50.00   | Healthy               |
        | 0x07      | Temp BMC         | 49.00   | Healthy               |
        | 0x08      | Temp CPU 1       | 63.00   | Healthy               |
        | 0x09      | Temp CPU 2       | 53.00   | Healthy               |
Hotswap Status: Active
Product name: 4009
Part number: 1062-0224
Serial number: 9017009420
Manufacturing date: Mon Oct 22 17:31:00 2018
Type: Node
Model: MSP805x
HPM versions:
	BMC: 1.3.091805DF
	FPGA: 1.0.00000000
	BIOS: 1.1.0916DD5E
Management Network:
        Management MAC: 00:a0:a5:cf:15:e8
        IP Source: dhcp
        IP: 10.24.97.76
        Subnet: 255.255.255.0
        Gateway: 10.24.97.3
        VLAN: FFD
Payload IPs :
	Network Interfaces:
		Id: 1, 
		Backplane: Base2, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:cf:15:e2
		IP Source: static


		Id: 2, 
		Backplane: Fabric1p1, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:cf:15:e3
		IP Source: static


		Id: 3, 
		Backplane: Fabric2p2, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:cf:15:e4
		IP Source: static


	Network Interfaces:
		Id: 1, 
		Backplane: Base1, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:cf:15:e5
		IP Source: static


		Id: 2, 
		Backplane: Fabric1p2, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:cf:15:e6
		IP Source: static


		Id: 3, 
		Backplane: Fabric2p1, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:cf:15:e7
		IP Source: static

================================

================================
SLOT #6
================================
Name: Node 6
Health: Healthy
Health Details: 
        | Sensor ID | Sensor Name      | Value   | Health                |
         ---------------------------------------------------------------- 
        | 0x0e      | Vcc +12V SUS     | 12.01   | Healthy               |
        | 0x0f      | Vcc +5V SUS      | 5.03    | Healthy               |
        | 0x10      | Vcc +2.5V SUS    | 2.48    | Healthy               |
        | 0x11      | Vcc +1.8V SUS    | 1.80    | Healthy               |
        | 0x12      | Vcc +1.5V SUS    | 1.49    | Healthy               |
        | 0x13      | Vcc +1.25V SUS   | 1.25    | Healthy               |
        | 0x14      | Vcc +0.75V SUS   | 0.75    | Healthy               |
        | 0x04      | Temp Inlet       | 27.00   | Healthy               |
        | 0x05      | Temp Outlet      | 48.00   | Healthy               |
        | 0x07      | Temp BMC         | 47.00   | Healthy               |
        | 0x08      | Temp CPU 1       | 60.00   | Healthy               |
        | 0x09      | Temp CPU 2       | 48.00   | Healthy               |
Hotswap Status: Active
Product name: 4009
Part number: 1062-0224
Serial number: 9017009473
Manufacturing date: Mon Oct 22 17:41:00 2018
Type: Node
Model: MSP805x
HPM versions:
	BMC: 1.3.091805DF
	FPGA: 1.0.00000000
	BIOS: 1.1.0916DD5E
Management Network:
        Management MAC: 00:a0:a5:cf:16:5c
        IP Source: dhcp
        IP: 10.24.97.164
        Subnet: 255.255.255.0
        Gateway: 10.24.97.3
        VLAN: FFD
Payload IPs :
	Network Interfaces:
		Id: 1, 
		Backplane: Base2, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:cf:16:56
		IP Source: static


		Id: 2, 
		Backplane: Fabric1p1, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:cf:16:57
		IP Source: static


		Id: 3, 
		Backplane: Fabric2p2, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:cf:16:58
		IP Source: static


	Network Interfaces:
		Id: 1, 
		Backplane: Base1, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:cf:16:59
		IP Source: static


		Id: 2, 
		Backplane: Fabric1p2, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:cf:16:5a
		IP Source: static


		Id: 3, 
		Backplane: Fabric2p1, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:cf:16:5b
		IP Source: static

================================

================================
SLOT #7
================================
Name: Node 7
Health: Healthy
Health Details: 
        | Sensor ID | Sensor Name      | Value   | Health                |
         ---------------------------------------------------------------- 
        | 0x0e      | Vcc +12V SUS     | 12.01   | Healthy               |
        | 0x0f      | Vcc +5V SUS      | 5.05    | Healthy               |
        | 0x10      | Vcc +2.5V SUS    | 2.48    | Healthy               |
        | 0x11      | Vcc +1.8V SUS    | 1.80    | Healthy               |
        | 0x12      | Vcc +1.5V SUS    | 1.50    | Healthy               |
        | 0x13      | Vcc +1.25V SUS   | 1.25    | Healthy               |
        | 0x14      | Vcc +0.75V SUS   | 0.76    | Healthy               |
        | 0x04      | Temp Inlet       | 26.00   | Healthy               |
        | 0x05      | Temp Outlet      | 45.00   | Healthy               |
        | 0x07      | Temp BMC         | 47.00   | Healthy               |
        | 0x08      | Temp CPU 1       | 61.00   | Healthy               |
        | 0x09      | Temp CPU 2       | 45.00   | Healthy               |
Hotswap Status: Active
Product name: 4009
Part number: 1062-0224
Serial number: 9017009348
Manufacturing date: Mon Oct 22 17:31:00 2018
Type: Node
Model: MSP805x
HPM versions:
	BMC: 1.3.091805DF
	FPGA: 1.0.00000000
	BIOS: 1.1.0916DD5E
Management Network:
        Management MAC: 00:a0:a5:cf:2d:9c
        IP Source: dhcp
        IP: 10.24.97.170
        Subnet: 255.255.255.0
        Gateway: 10.24.97.3
        VLAN: FFD
Payload IPs :
	Network Interfaces:
		Id: 1, 
		Backplane: Base2, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:cf:2d:96
		IP Source: static


		Id: 2, 
		Backplane: Fabric1p1, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:cf:2d:97
		IP Source: static


		Id: 3, 
		Backplane: Fabric2p2, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:cf:2d:98
		IP Source: static


	Network Interfaces:
		Id: 1, 
		Backplane: Base1, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:cf:2d:99
		IP Source: static


		Id: 2, 
		Backplane: Fabric1p2, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:cf:2d:9a
		IP Source: static


		Id: 3, 
		Backplane: Fabric2p1, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:cf:2d:9b
		IP Source: static

================================

================================
SLOT #8
================================
Name: Node 8
Health: Healthy
Health Details: 
        | Sensor ID | Sensor Name      | Value   | Health                |
         ---------------------------------------------------------------- 
        | 0x0e      | Vcc +12V SUS     | 12.01   | Healthy               |
        | 0x0f      | Vcc +5V SUS      | 5.03    | Healthy               |
        | 0x10      | Vcc +2.5V SUS    | 2.48    | Healthy               |
        | 0x11      | Vcc +1.8V SUS    | 1.81    | Healthy               |
        | 0x12      | Vcc +1.5V SUS    | 1.50    | Healthy               |
        | 0x13      | Vcc +1.25V SUS   | 1.25    | Healthy               |
        | 0x14      | Vcc +0.75V SUS   | 0.76    | Healthy               |
        | 0x04      | Temp Inlet       | 26.00   | Healthy               |
        | 0x05      | Temp Outlet      | 44.00   | Healthy               |
        | 0x07      | Temp BMC         | 46.00   | Healthy               |
        | 0x08      | Temp CPU 1       | 60.00   | Healthy               |
        | 0x09      | Temp CPU 2       | 47.00   | Healthy               |
Hotswap Status: Active
Product name: 4009
Part number: 1062-0224
Serial number: 9017009426
Manufacturing date: Mon Oct 22 16:34:00 2018
Type: Node
Model: MSP805x
HPM versions:
	BMC: 1.3.091805DF
	FPGA: 1.0.00000000
	BIOS: 1.1.0916DD5E
Management Network:
        Management MAC: 00:a0:a5:cf:17:18
        IP Source: dhcp
        IP: 10.24.97.91
        Subnet: 255.255.255.0
        Gateway: 10.24.97.3
        VLAN: FFD
Payload IPs :
	Network Interfaces:
		Id: 1, 
		Backplane: Base2, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:cf:17:12
		IP Source: static


		Id: 2, 
		Backplane: Fabric1p1, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:cf:17:13
		IP Source: static


		Id: 3, 
		Backplane: Fabric2p2, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:cf:17:14
		IP Source: static


	Network Interfaces:
		Id: 1, 
		Backplane: Base1, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:cf:17:15
		IP Source: static


		Id: 2, 
		Backplane: Fabric1p2, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:cf:17:16
		IP Source: static


		Id: 3, 
		Backplane: Fabric2p1, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:cf:17:17
		IP Source: static

================================

================================
SLOT #9
================================
Name: Node 9
Health: Healthy
Health Details: 
        | Sensor ID | Sensor Name      | Value   | Health                |
         ---------------------------------------------------------------- 
        | 0x0e      | Vcc +12V SUS     | 12.06   | Healthy               |
        | 0x0f      | Vcc +5V SUS      | 5.03    | Healthy               |
        | 0x10      | Vcc +2.5V SUS    | 2.48    | Healthy               |
        | 0x11      | Vcc +1.8V SUS    | 1.80    | Healthy               |
        | 0x12      | Vcc +1.5V SUS    | 1.50    | Healthy               |
        | 0x13      | Vcc +1.25V SUS   | 1.25    | Healthy               |
        | 0x14      | Vcc +0.75V SUS   | 0.76    | Healthy               |
        | 0x04      | Temp Inlet       | 27.00   | Healthy               |
        | 0x05      | Temp Outlet      | 45.00   | Healthy               |
        | 0x07      | Temp BMC         | 46.00   | Healthy               |
        | 0x08      | Temp CPU 1       | 58.00   | Healthy               |
        | 0x09      | Temp CPU 2       | 50.00   | Healthy               |
Hotswap Status: Active
Product name: 4009
Part number: 1062-0224
Serial number: 9017009285
Manufacturing date: Mon Oct 22 16:33:00 2018
Type: Node
Model: MSP805x
HPM versions:
	BMC: 1.3.091805DF
	FPGA: 1.0.00000000
	BIOS: 1.1.0916DD5E
Management Network:
        Management MAC: 00:a0:a5:ce:64:0c
        IP Source: dhcp
        IP: 10.24.97.154
        Subnet: 255.255.255.0
        Gateway: 10.24.97.3
        VLAN: FFD
Payload IPs :
	Network Interfaces:
		Id: 1, 
		Backplane: Base2, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:ce:64:06
		IP Source: static


		Id: 2, 
		Backplane: Fabric1p1, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:ce:64:07
		IP Source: static


		Id: 3, 
		Backplane: Fabric2p2, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:ce:64:08
		IP Source: static


	Network Interfaces:
		Id: 1, 
		Backplane: Base1, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:ce:64:09
		IP Source: static


		Id: 2, 
		Backplane: Fabric1p2, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:ce:64:0a
		IP Source: static


		Id: 3, 
		Backplane: Fabric2p1, 
		IP: 0.0.0.0/0
		Gateway: 0.0.0.0
		Mac: 00:a0:a5:ce:64:0b
		IP Source: static

================================

*******************************
Original JSON string
*******************************
{ "name": "Platform #1", "number": "1", "chassis": "ms2900", "health": "Green", "fans":[ {"number": "1", "name": "Fan 1", "type": "fan", "health": "Green", "rpm": "8239","alarm": {"alarmlevel": "None"}, "LedIdentify": {"status": "off"}, "hotswapStatus":{"state": "M4", "text": "Active"}}, {"number": "2", "name": "Fan 2", "type": "fan", "health": "Green", "rpm": "8239","alarm": {"alarmlevel": "None"}, "LedIdentify": {"status": "off"}, "hotswapStatus":{"state": "M4", "text": "Active"}}, {"number": "3", "name": "Fan 3", "type": "fan", "health": "Green", "rpm": "8239","alarm": {"alarmlevel": "None"}, "LedIdentify": {"status": "off"}, "hotswapStatus":{"state": "M4", "text": "Active"}}, {"number": "4", "name": "Fan 4", "type": "fan", "health": "Green", "rpm": "8316","alarm": {"alarmlevel": "None"}, "LedIdentify": {"status": "off"}, "hotswapStatus":{"state": "M4", "text": "Active"}}, {"number": "5", "name": "Fan 5", "type": "fan", "health": "Green", "rpm": "8239","alarm": {"alarmlevel": "None"}, "LedIdentify": {"status": "off"}, "hotswapStatus":{"state": "M4", "text": "Active"}} ], "type": "platform", "components": [{"number": "10", "name": "HubNode 1", "health": "Green", "fruInfo": {"mfgDate": "Wed Oct 24 14:57:00 2018", "boardMfg": "Kontron", "boardProductName": "MSH8900", "boardProductPart": "T4301X_2-X", "boardSerialNumber": "9017009237"},"hotswapStatus":{"state": "M4", "text": "Active"},"type":"hubnode", "HubNodeFeatures":{"SwitchSpeedSupport": "1", "PortModeSupport": "0"}, "versions" : [{ "name" : "BMC", "major" : "3", "minor" : "16", "revision" : "09289D46"},{ "name" : "FPGA", "major" : "2", "minor" : "06", "revision" : "00000000"}],"model": "MSH8900", "isUpdating" : "0", "managementIP": "10.24.97.89", "managementMAC": "00:a0:a5:cf:9f:3b", "alarm": {"alarmlevel": "None", "sensors":[]}, "LedIdentify": {"status": "off"}, "components": [{ "description": "Switch 1", "number": "1", "hotswapStatus":{"state": "M4", "text": "Active"}, "networkInterfaces": [{ "id": "1", "backplane": "Unknown", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:cf:9f:3b"}]}], "status": "Active"}, {"number": "11", "name": "HubNode 2", "health": "Green", "fruInfo": {"mfgDate": "Wed Oct 24 15:05:00 2018", "boardMfg": "Kontron", "boardProductName": "MSH8900", "boardProductPart": "T4301X_2-X", "boardSerialNumber": "9017009261"},"hotswapStatus":{"state": "M4", "text": "Active"},"type":"hubnode", "HubNodeFeatures":{"SwitchSpeedSupport": "1", "PortModeSupport": "0"}, "versions" : [{ "name" : "BMC", "major" : "3", "minor" : "16", "revision" : "09289D46"},{ "name" : "FPGA", "major" : "2", "minor" : "06", "revision" : "00000000"}],"model": "MSH8900", "isUpdating" : "0", "managementIP": "10.24.97.79", "managementMAC": "00:a0:a5:cf:a0:5b", "alarm": {"alarmlevel": "None", "sensors":[]}, "LedIdentify": {"status": "off"}, "components": [{ "description": "Switch 2", "number": "1", "hotswapStatus":{"state": "M4", "text": "Active"}, "networkInterfaces": [{ "id": "1", "backplane": "Unknown", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:cf:a0:5b"}]}], "status": "Standby"}, {"number": "1", "name": "Node 1", "health": "Green", "fruInfo": {"mfgDate": "Mon Oct 22 16:31:00 2018", "boardMfg": "Kontron", "boardProductName": "4009", "boardProductPart": "1062-0224", "boardSerialNumber": "9017009440"},"hotswapStatus":{"state": "M4", "text": "Active"},"type":"node", "versions" : [{ "name" : "BMC", "major" : "1", "minor" : "03", "revision" : "091805DF"},{ "name" : "FPGA", "major" : "1", "minor" : "00", "revision" : "00000000"},{ "name" : "BIOS", "major" : "1", "minor" : "01", "revision" : "0916DD5E"}],"model": "MSP805x", "isUpdating" : "0", "managementIP": "10.24.97.92", "managementMAC": "00:a0:a5:cf:13:30", "alarm": {"alarmlevel": "None", "sensors":[]}, "LedIdentify": {"status": "off"}, "components": [{ "description": "Payload1       ", "number": "1", "hotswapStatus":{"state": "M4", "text": "Active"}, "networkInterfaces": [{ "id": "1", "backplane": "Base2", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:cf:13:2a"}, { "id": "2", "backplane": "Fabric1p1", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:cf:13:2b"}, { "id": "3", "backplane": "Fabric2p2", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:cf:13:2c"}]}, { "description": "Payload2       ", "number": "2", "hotswapStatus":{"state": "M4", "text": "Active"}, "networkInterfaces": [{ "id": "1", "backplane": "Base1", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:cf:13:2d"}, { "id": "2", "backplane": "Fabric1p2", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:cf:13:2e"}, { "id": "3", "backplane": "Fabric2p1", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:cf:13:2f"}]}] }, {"number": "2", "name": "Node 2", "health": "Green", "fruInfo": {"mfgDate": "Mon Oct 22 16:31:00 2018", "boardMfg": "Kontron", "boardProductName": "4009", "boardProductPart": "1062-0224", "boardSerialNumber": "9017009444"},"hotswapStatus":{"state": "M4", "text": "Active"},"type":"node", "versions" : [{ "name" : "BMC", "major" : "1", "minor" : "03", "revision" : "091805DF"},{ "name" : "FPGA", "major" : "1", "minor" : "00", "revision" : "00000000"},{ "name" : "BIOS", "major" : "1", "minor" : "01", "revision" : "0916DD5E"}],"model": "MSP805x", "isUpdating" : "0", "managementIP": "10.24.97.50", "managementMAC": "00:a0:a5:cf:16:e4", "alarm": {"alarmlevel": "None", "sensors":[]}, "LedIdentify": {"status": "off"}, "components": [{ "description": "Payload1       ", "number": "1", "hotswapStatus":{"state": "M4", "text": "Active"}, "networkInterfaces": [{ "id": "1", "backplane": "Base2", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:cf:16:de"}, { "id": "2", "backplane": "Fabric1p1", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:cf:16:df"}, { "id": "3", "backplane": "Fabric2p2", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:cf:16:e0"}]}, { "description": "Payload2       ", "number": "2", "hotswapStatus":{"state": "M4", "text": "Active"}, "networkInterfaces": [{ "id": "1", "backplane": "Base1", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:cf:16:e1"}, { "id": "2", "backplane": "Fabric1p2", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:cf:16:e2"}, { "id": "3", "backplane": "Fabric2p1", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:cf:16:e3"}]}] }, {"number": "3", "name": "Node 3", "health": "Green", "fruInfo": {"mfgDate": "Mon Oct 22 16:34:00 2018", "boardMfg": "Kontron", "boardProductName": "4009", "boardProductPart": "1062-0224", "boardSerialNumber": "9017009451"},"hotswapStatus":{"state": "M4", "text": "Active"},"type":"node", "versions" : [{ "name" : "BMC", "major" : "1", "minor" : "03", "revision" : "091805DF"},{ "name" : "FPGA", "major" : "1", "minor" : "00", "revision" : "00000000"},{ "name" : "BIOS", "major" : "1", "minor" : "01", "revision" : "0916DD5E"}],"model": "MSP805x", "isUpdating" : "0", "managementIP": "10.24.97.144", "managementMAC": "00:a0:a5:cf:16:54", "alarm": {"alarmlevel": "None", "sensors":[]}, "LedIdentify": {"status": "off"}, "components": [{ "description": "Payload1       ", "number": "1", "hotswapStatus":{"state": "M4", "text": "Active"}, "networkInterfaces": [{ "id": "1", "backplane": "Base2", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:cf:16:4e"}, { "id": "2", "backplane": "Fabric1p1", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:cf:16:4f"}, { "id": "3", "backplane": "Fabric2p2", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:cf:16:50"}]}, { "description": "Payload2       ", "number": "2", "hotswapStatus":{"state": "M4", "text": "Active"}, "networkInterfaces": [{ "id": "1", "backplane": "Base1", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:cf:16:51"}, { "id": "2", "backplane": "Fabric1p2", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:cf:16:52"}, { "id": "3", "backplane": "Fabric2p1", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:cf:16:53"}]}] }, {"number": "4", "name": "Node 4", "health": "Green", "fruInfo": {"mfgDate": "Mon Oct 22 17:29:00 2018", "boardMfg": "Kontron", "boardProductName": "4009", "boardProductPart": "1062-0224", "boardSerialNumber": "9017009406"},"hotswapStatus":{"state": "M4", "text": "Active"},"type":"node", "versions" : [{ "name" : "BMC", "major" : "1", "minor" : "03", "revision" : "091805DF"},{ "name" : "FPGA", "major" : "1", "minor" : "00", "revision" : "00000000"},{ "name" : "BIOS", "major" : "1", "minor" : "01", "revision" : "0916DD5E"}],"model": "MSP805x", "isUpdating" : "0", "managementIP": "10.24.97.167", "managementMAC": "00:a0:a5:cf:15:f8", "alarm": {"alarmlevel": "None", "sensors":[]}, "LedIdentify": {"status": "off"}, "components": [{ "description": "Payload1       ", "number": "1", "hotswapStatus":{"state": "M4", "text": "Active"}, "networkInterfaces": [{ "id": "1", "backplane": "Base2", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:cf:15:f2"}, { "id": "2", "backplane": "Fabric1p1", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:cf:15:f3"}, { "id": "3", "backplane": "Fabric2p2", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:cf:15:f4"}]}, { "description": "Payload2       ", "number": "2", "hotswapStatus":{"state": "M4", "text": "Active"}, "networkInterfaces": [{ "id": "1", "backplane": "Base1", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:cf:15:f5"}, { "id": "2", "backplane": "Fabric1p2", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:cf:15:f6"}, { "id": "3", "backplane": "Fabric2p1", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:cf:15:f7"}]}] }, {"number": "5", "name": "Node 5", "health": "Green", "fruInfo": {"mfgDate": "Mon Oct 22 17:31:00 2018", "boardMfg": "Kontron", "boardProductName": "4009", "boardProductPart": "1062-0224", "boardSerialNumber": "9017009420"},"hotswapStatus":{"state": "M4", "text": "Active"},"type":"node", "versions" : [{ "name" : "BMC", "major" : "1", "minor" : "03", "revision" : "091805DF"},{ "name" : "FPGA", "major" : "1", "minor" : "00", "revision" : "00000000"},{ "name" : "BIOS", "major" : "1", "minor" : "01", "revision" : "0916DD5E"}],"model": "MSP805x", "isUpdating" : "0", "managementIP": "10.24.97.76", "managementMAC": "00:a0:a5:cf:15:e8", "alarm": {"alarmlevel": "None", "sensors":[]}, "LedIdentify": {"status": "off"}, "components": [{ "description": "Payload1       ", "number": "1", "hotswapStatus":{"state": "M4", "text": "Active"}, "networkInterfaces": [{ "id": "1", "backplane": "Base2", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:cf:15:e2"}, { "id": "2", "backplane": "Fabric1p1", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:cf:15:e3"}, { "id": "3", "backplane": "Fabric2p2", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:cf:15:e4"}]}, { "description": "Payload2       ", "number": "2", "hotswapStatus":{"state": "M4", "text": "Active"}, "networkInterfaces": [{ "id": "1", "backplane": "Base1", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:cf:15:e5"}, { "id": "2", "backplane": "Fabric1p2", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:cf:15:e6"}, { "id": "3", "backplane": "Fabric2p1", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:cf:15:e7"}]}] }, {"number": "6", "name": "Node 6", "health": "Green", "fruInfo": {"mfgDate": "Mon Oct 22 17:41:00 2018", "boardMfg": "Kontron", "boardProductName": "4009", "boardProductPart": "1062-0224", "boardSerialNumber": "9017009473"},"hotswapStatus":{"state": "M4", "text": "Active"},"type":"node", "versions" : [{ "name" : "BMC", "major" : "1", "minor" : "03", "revision" : "091805DF"},{ "name" : "FPGA", "major" : "1", "minor" : "00", "revision" : "00000000"},{ "name" : "BIOS", "major" : "1", "minor" : "01", "revision" : "0916DD5E"}],"model": "MSP805x", "isUpdating" : "0", "managementIP": "10.24.97.164", "managementMAC": "00:a0:a5:cf:16:5c", "alarm": {"alarmlevel": "None", "sensors":[]}, "LedIdentify": {"status": "off"}, "components": [{ "description": "Payload1       ", "number": "1", "hotswapStatus":{"state": "M4", "text": "Active"}, "networkInterfaces": [{ "id": "1", "backplane": "Base2", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:cf:16:56"}, { "id": "2", "backplane": "Fabric1p1", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:cf:16:57"}, { "id": "3", "backplane": "Fabric2p2", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:cf:16:58"}]}, { "description": "Payload2       ", "number": "2", "hotswapStatus":{"state": "M4", "text": "Active"}, "networkInterfaces": [{ "id": "1", "backplane": "Base1", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:cf:16:59"}, { "id": "2", "backplane": "Fabric1p2", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:cf:16:5a"}, { "id": "3", "backplane": "Fabric2p1", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:cf:16:5b"}]}] }, {"number": "7", "name": "Node 7", "health": "Green", "fruInfo": {"mfgDate": "Mon Oct 22 17:31:00 2018", "boardMfg": "Kontron", "boardProductName": "4009", "boardProductPart": "1062-0224", "boardSerialNumber": "9017009348"},"hotswapStatus":{"state": "M4", "text": "Active"},"type":"node", "versions" : [{ "name" : "BMC", "major" : "1", "minor" : "03", "revision" : "091805DF"},{ "name" : "FPGA", "major" : "1", "minor" : "00", "revision" : "00000000"},{ "name" : "BIOS", "major" : "1", "minor" : "01", "revision" : "0916DD5E"}],"model": "MSP805x", "isUpdating" : "0", "managementIP": "10.24.97.170", "managementMAC": "00:a0:a5:cf:2d:9c", "alarm": {"alarmlevel": "None", "sensors":[]}, "LedIdentify": {"status": "off"}, "components": [{ "description": "Payload1       ", "number": "1", "hotswapStatus":{"state": "M4", "text": "Active"}, "networkInterfaces": [{ "id": "1", "backplane": "Base2", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:cf:2d:96"}, { "id": "2", "backplane": "Fabric1p1", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:cf:2d:97"}, { "id": "3", "backplane": "Fabric2p2", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:cf:2d:98"}]}, { "description": "Payload2       ", "number": "2", "hotswapStatus":{"state": "M4", "text": "Active"}, "networkInterfaces": [{ "id": "1", "backplane": "Base1", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:cf:2d:99"}, { "id": "2", "backplane": "Fabric1p2", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:cf:2d:9a"}, { "id": "3", "backplane": "Fabric2p1", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:cf:2d:9b"}]}] }, {"number": "8", "name": "Node 8", "health": "Green", "fruInfo": {"mfgDate": "Mon Oct 22 16:34:00 2018", "boardMfg": "Kontron", "boardProductName": "4009", "boardProductPart": "1062-0224", "boardSerialNumber": "9017009426"},"hotswapStatus":{"state": "M4", "text": "Active"},"type":"node", "versions" : [{ "name" : "BMC", "major" : "1", "minor" : "03", "revision" : "091805DF"},{ "name" : "FPGA", "major" : "1", "minor" : "00", "revision" : "00000000"},{ "name" : "BIOS", "major" : "1", "minor" : "01", "revision" : "0916DD5E"}],"model": "MSP805x", "isUpdating" : "0", "managementIP": "10.24.97.91", "managementMAC": "00:a0:a5:cf:17:18", "alarm": {"alarmlevel": "None", "sensors":[]}, "LedIdentify": {"status": "off"}, "components": [{ "description": "Payload1       ", "number": "1", "hotswapStatus":{"state": "M4", "text": "Active"}, "networkInterfaces": [{ "id": "1", "backplane": "Base2", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:cf:17:12"}, { "id": "2", "backplane": "Fabric1p1", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:cf:17:13"}, { "id": "3", "backplane": "Fabric2p2", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:cf:17:14"}]}, { "description": "Payload2       ", "number": "2", "hotswapStatus":{"state": "M4", "text": "Active"}, "networkInterfaces": [{ "id": "1", "backplane": "Base1", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:cf:17:15"}, { "id": "2", "backplane": "Fabric1p2", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:cf:17:16"}, { "id": "3", "backplane": "Fabric2p1", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:cf:17:17"}]}] }, {"number": "9", "name": "Node 9", "health": "Green", "fruInfo": {"mfgDate": "Mon Oct 22 16:33:00 2018", "boardMfg": "Kontron", "boardProductName": "4009", "boardProductPart": "1062-0224", "boardSerialNumber": "9017009285"},"hotswapStatus":{"state": "M4", "text": "Active"},"type":"node", "versions" : [{ "name" : "BMC", "major" : "1", "minor" : "03", "revision" : "091805DF"},{ "name" : "FPGA", "major" : "1", "minor" : "00", "revision" : "00000000"},{ "name" : "BIOS", "major" : "1", "minor" : "01", "revision" : "0916DD5E"}],"model": "MSP805x", "isUpdating" : "0", "managementIP": "10.24.97.154", "managementMAC": "00:a0:a5:ce:64:0c", "alarm": {"alarmlevel": "None", "sensors":[]}, "LedIdentify": {"status": "off"}, "components": [{ "description": "Payload1       ", "number": "1", "hotswapStatus":{"state": "M4", "text": "Active"}, "networkInterfaces": [{ "id": "1", "backplane": "Base2", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:ce:64:06"}, { "id": "2", "backplane": "Fabric1p1", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:ce:64:07"}, { "id": "3", "backplane": "Fabric2p2", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:ce:64:08"}]}, { "description": "Payload2       ", "number": "2", "hotswapStatus":{"state": "M4", "text": "Active"}, "networkInterfaces": [{ "id": "1", "backplane": "Base1", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:ce:64:09"}, { "id": "2", "backplane": "Fabric1p2", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:ce:64:0a"}, { "id": "3", "backplane": "Fabric2p1", "ip": ["0", "0", "0", "0"], "gateway": ["0", "0", "0", "0"], "netmask": "0", "ipSource": "static", "mac": "00:a0:a5:ce:64:0b"}]}] }, { "name": "PSU", "components": [{"id": "PSU1", "number": "1", "name": "Power Supply 1", "health": "Green", "type": "psu", "hotswapStatus":{"state": "M4", "text": "Active"},"alarm": {"alarmlevel": "None"}, "tempInlet": "20.00", "tempOutlet": "28.00", "vIn": "205.00", "powerOut": "368", "powerScale": "1400","peakConsumption": "488", "averageConsumption": "279"},{"id": "PSU2", "number": "2", "name": "Power Supply 2", "health": "Green", "type": "psu", "hotswapStatus":{"state": "M4", "text": "Active"},"alarm": {"alarmlevel": "None"}, "tempInlet": "21.00", "tempOutlet": "28.00", "vIn": "204.00", "powerOut": "384", "powerScale": "1400","peakConsumption": "480", "averageConsumption": "285"}]}], "switchOID": {"oid": "1.3.6.1.4.1.6603"}, "alarm": {"alarmlevel": "None",  "components" : [ {"nodes" : [] } , {"psu" : [] }, {"fans" : [] }], "text": ""}, "LedIdentify": {"status": "off"}}